Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 7 of 7 for “"electrode position"”.
-
Theoretical aspects of electrodeposition in charged porous media
Electrodeposition is a fascinating electrochemical phenomenon that contains deep physical insights and has broad practical applications. At the heart of the physics governing electrodeposition is a competition between a destabilizing force caused by surface crests growing more rapidly than surface …
-
Two-channel surface stimulation for the correction of drop foot.
… transcutaneous FES systems require the accurate positioning of surface electrodes on the skin so that the appropriate nerves are activated to give the desired muscle response. Many people find electrode positioning difficult. 2 This project examined the feasibility of using two channels of …
-
A Self-Potential for Monitoring Self-Sustaining Treatment for Active Remediation (STAR)
… distance between the reaction front and the SP electrode position. R-squared for a linear regression of measured SP and the distance was 0.83, indicating that the majority of voltage anomaly had contribution to distance of the electrode to the smoldering front. Overall, this research …
-
Ermittlung der tatsächlich erzielten Elektrodenpositionen nach tiefer Hirnstimulation mittels frühem postoperativem 3D CT
… was to show whether it is possible to locate DBS electrodes implanted into the human brain accurately in an early postoperative 3D-CT that was fused to preoperative planning data. Preoperative targeting was performed statistically with respect to the midcommissural point (MCP) and (in subthalamic …
-
Bioelectrical impedance analysis as a predictor of fish health and energy content in juvenile rainbow trout (Oncorhynchus mykiss)
… content using bomb calorimetry or proximate composition analysis; however, both of these methods necessitate sacrificing the fish in order to obtain accurate data. This has led to research into novel non-lethal methods of analyzing fish tissue so as to determine the body composition and health …
-
Electro-anatomical models of the cochlear implant
… For instance, across-patient variation in electrode position and insertion depth is clearly present, as are differential amounts of residual spiral ganglion survival, fibrous tissue formation and electrode encapsulation, cochlear ossification, and idiosyncratic damage to adjacent cochlear …
-
Restoration of hand and arm function to people with tetraplegia as a result of damage to the spinal cord in the neck through the use of functional electrical stimulation (FES).
… was controlled using an IMU based shoulder position sensor strapped across the contralateral shoulder and did not use a rigid arm splint. This allowed flexibility in electrode position and more people were able to use the system. The device was programmed to perform two hand movements – the …