Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"eight-channel"”.

  1. Tele: Using Vernacular Performance Practices in an Eight-Channel Environment

    Examines the use of vernacular, country guitar styles in an electro-acoustic environment. Special attention is given to performance practices and explanation of techniques. Electro-acoustic techniques-including sound design and spatialization-are given with sonogram analyses and excerpts from the …

    unt Repository record for Tele: Using Vernacular Performance Practices in an Eight-Channel Environment (opens in a new tab)

  2. Shedding light on the molecular interactomes of fast, complex biological processes using multispectral imaging with uncompromised spatiotemporal resolution

    … as labels are imaged sequentially in independent channels. These compounding issues drastically limit our understanding of highly-dynamic, complex biological processes, for instance, endosomal receptor sorting. This process occurs within a few seconds and is regulated by tens, or hundreds, of …

    cambridge Repository record for Shedding light on the molecular interactomes of fast, complex biological processes using multispectral imaging with uncompromised spatiotemporal resolution (opens in a new tab)

  3. Predicting continuous hand pose from wearable EMG sensor data using transformer-based deep-learning models

    … (EMG) signals collected with a low-cost, eight-channel wearable armband. A modular software laboratory was developed to support data acquisition, synchronization, visualization, model training, and inference. A single-subject, three-hour dataset of synchronized EMG and hand-tracking data …

    utc Repository record for Predicting continuous hand pose from wearable EMG sensor data using transformer-based deep-learning models (opens in a new tab)

  4. Design and characterization of the measurement electronics for a magnetic induction tomography imaging system

    … of testing the designed hardware, a three channel MIT measuring system was assembled, and various experiments were run on the system. Several different samples with high conductivity (metal sheets) or low conductivity (saline solution) were used to test the performance of the designed …

    cape-town Repository record for Design and characterization of the measurement electronics for a magnetic induction tomography imaging system (opens in a new tab)

  5. An electronically steered, wearable transcranial doppler ultrasound system

    … autonomous CBFV measurement. A first-generation, eight channel printed circuit board prototype system has been designed, fabricated, and experimentally tested. Characterization of the prototype system using a Doppler flow phantom resulted in a normalized root-mean-square error of < 3.5% over the …

    mit Repository record for An electronically steered, wearable transcranial doppler ultrasound system (opens in a new tab)

  6. Parallel transmission for magnetic resonance imaging on a 9.4 Tesla Human System.

    … of 9.4 Tesla (T) in the human brain with an eight-channel transmit system, using accelerated (x 4) RF pulses designed to create arbitrarily shaped excitation profiles. To achieve satisfactory excitation accuracy, k-space errors due to gradient system imperfection had to be accurately …

    umn Repository record for Parallel transmission for magnetic resonance imaging on a 9.4 Tesla Human System. (opens in a new tab)

  7. A Study on High-Speed Magnetic Induction Tomography Instrumentation Aiming at Low Conductivity Applications

    … technique were developed and implemented.The eight channel Cardiff Mk2c aimed at the multiphase flow in oil pipes. The Cardiff Mk2c achieved a frame rate of 12.5 frames per second making it the fastest 10 MHz multichannel MIT system until this thesis was submitted. Its precision was down to 15 …

    southwales Repository record for A Study on High-Speed Magnetic Induction Tomography Instrumentation Aiming at Low Conductivity Applications (opens in a new tab)

  8. An original composition, Diamundo, and a historical survey of music spatialization

    … trumpet, and trombone. The ensemble and the eight-channel loudspeakers are spatialized. The piece is divided in six movements without interruption. The first five movements are separated by 4 cadenzas for the solo instruments. Most of the motives, rhythms, and harmonies were generated having …

    lsu-thes Repository record for An original composition, Diamundo, and a historical survey of music spatialization (opens in a new tab)

  9. jn4.gesture: An interactive composition for dance.

    … and control the diffusion of sound in an eight channel sound system. The video recording of the performance was made on April 22, 2002. The work was produced in a specialized performance space using two computer projectors and a state of the art sound system. Arleen Sugano designed the …

    unt Repository record for jn4.gesture: An interactive composition for dance. (opens in a new tab)

  10. Long-term, subdermal implantable EEG recording and seizure detection

    … this need by proposing a subdermal implantable, eight-channel EEG recorder and seizure detector that has two modes of operation: diagnosis and seizure counting. In the diagnosis mode, EEG is continuously recorded with a 500 Hz bandwidth. This bandwidth is five times higher than typically done to …

    mit Repository record for Long-term, subdermal implantable EEG recording and seizure detection (opens in a new tab)

  11. Smart Base Station Antenna Performance for Several Scenarios - an Experimental and Modeling Investigation

    … various propagation environment scenarios. An eight-channel Virginia Tech smart base station antenna testbed was developed to investigate performances of three reverse link diversity methods. The experiment campaign resulted in 245 sets of collected data over 83 measurement sites, which were …

    vt Repository record for Smart Base Station Antenna Performance for Several Scenarios - an Experimental and Modeling Investigation (opens in a new tab)

  12. Electroencephalography in a Teaching Hospital

    … This instrument, first having only a single channel, grew to a four channel machine by 1944 and proved to have more desirable characteristics than any available commercially at that time. The Service’s present eight channel electroencephalograph was also built under the direction of Dale. …

    loma-linda Repository record for Electroencephalography in a Teaching Hospital (opens in a new tab)

  13. Sedimentary texture similarities in deep-marine channel sandstones: Insights from petrographic characterization of Cretaceous Tres Pasos Formation, Chile

    Deep-marine channels are conduits for turbidity currents that transport sediment from the continental shelf to the deep ocean floor. Along the way, some of the sediment suspended in the current is deposited within the channel whereas the rest of the sediment makes its way to deeper water to …

    vt Repository record for Sedimentary texture similarities in deep-marine channel sandstones: Insights from petrographic characterization of Cretaceous Tres Pasos Formation, Chile (opens in a new tab)

  14. Cross-education and neuromuscular factors relating to the prevention and rehabilitation of anterior cruciate ligament (ACL) knee injuries

    … potential effects of cross-education. Methods: Eighteen recreationally active females (21.2 ± 3 years of age, with a stature of 166.4 ± 6.6 cm, and body mass of 61.9 ± 3.6 kg) were recruited (n = 18). The participants all completed a six week bilateral plyometrics programme to raise their …

    london-metro Repository record for Cross-education and neuromuscular factors relating to the prevention and rehabilitation of anterior cruciate ligament (ACL) knee injuries (opens in a new tab)

  15. Development Of A Field-Portable Miniature Mass Spectrometer Designed For In-Situ Analysis And Ion Trap Miniaturization

    … 4 details the fabrication and operation of an eight-channel array of 1/3rd scale rectilinear ion traps (RITs) constructed monolithically with stereolithography apparatus (SLA). Each ion trap channel inside the array is independently isolated and can be controlled with a unique set of RF and DC …

    purdue-thes Repository record for Development Of A Field-Portable Miniature Mass Spectrometer Designed For In-Situ Analysis And Ion Trap Miniaturization (opens in a new tab)