Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 86 for “"dosimetric"”.

  1. Advanced brachytherapy dosimetric considerations

    The practice of brachytherapy and brachytherapy dosimetry was investigated with emphasis on evaluations of dose distributions and shielding considerations for both photon- and neutron-emitting radionuclides. Monte Carlo simulation methods were employed to calculate dose distributions for virtual …

    mit Repository record for Advanced brachytherapy dosimetric considerations (opens in a new tab)

  2. Development of A Remote Dosimetric Audit Framework For Carbon Therapy

    <p>Carbon ion therapy is available at over a dozen institutions around the world and is being employed for treatment of cancer. The increased biological effect of carbon compared to conventional photon-based radiotherapy holds promise for the therapeutic benefit in historically radioresistant …

    uthsc Repository record for Development of A Remote Dosimetric Audit Framework For Carbon Therapy (opens in a new tab)

  3. Dosimetric characterization of a miniature x-ray source for biophysics studies

    Tritium is a low energy beta emitter that is found in abundance at CANDU nuclear power plants and is a cause of concern since it accounts for roughly thirty three percent of the total occupational exposure of nuclear workers. According to current standards, the radiation weighting factor for all …

    uoit Repository record for Dosimetric characterization of a miniature x-ray source for biophysics studies (opens in a new tab)

  4. Combined methods and instrumentation for dosimetric monitoring of the large fluence hadron irradiations /

    Dosimetry in the routine sense is the measurement of the absorbed dose in biological tissues and matter delivered by ionizing radiation or particle beams. Dosimetry is widely applied in the field of medical physics where it is inevitable for assessment of the radiation dose received by personnel …

    vilnius Repository record for Combined methods and instrumentation for dosimetric monitoring of the large fluence hadron irradiations / (opens in a new tab)

  5. A Complete Dosimetric Model of the Gamma Knife Perfexion Using Penelope Monte Carlo Codes

    The Gamma Knife Perfexion is a radiosurgical treatment device used to irradiate targets in the head. It uses 192 high-activity Cobalt-60 sources collimated to a common focus to impart radiological damage to the target structure while minimizing dose to adjacent healthy tissue. Tungsten collimators …

    wfu Repository record for A Complete Dosimetric Model of the Gamma Knife Perfexion Using Penelope Monte Carlo Codes (opens in a new tab)

  6. A Dosimetric Study of a VMAT Head and Neck Treatment Plan Using TLDs and Gafchromic Films

    … used in side an anthropomorphic phantom for this dosimetric study. These two dosimeters have been used to determine the dose in specific points and to compare the results with the computer plan. Also, EBT2 films have been used to study the isodose distribution on the anthropomorphic phantom …

    south-carolina Repository record for A Dosimetric Study of a VMAT Head and Neck Treatment Plan Using TLDs and Gafchromic Films (opens in a new tab)

  7. "Dosimetric Properties of Clinac Electron Beam Depth Doses: An Investigation of Electron Beam ""Golden"" Data Set"

    Made available in DSpace on 2017-07-06T18:55:55Z (GMT). No. of bitstreams: 2 Qayyum_Muqeem_A_MS.pdf: 3223744 bytes, checksum: a4b1aa0ed198965f4f43c8882d87d2ec (MD5) license.txt: 4813 bytes, checksum: 715c4321821a960fa1a1e91d2ac7ebce (MD5) Previous issue date: 2006

    uiuc Repository record for "Dosimetric Properties of Clinac Electron Beam Depth Doses: An Investigation of Electron Beam ""Golden"" Data Set" (opens in a new tab)

  8. Study of Dosimetric and Thermal Properties of a Newly Developed Thermo-brachytherapy Seed for Treatment of Solid Tumors

    Studies on the curative effects of hyperthermia and radiation therapy on treatment of cancer show strong evidence of synergistic enhancement when both radiation and hyperthermia treatment modalities are applied simultaneously. A variety of tissue heating approaches developed to date still fail to …

    ohiolink Repository record for Study of Dosimetric and Thermal Properties of a Newly Developed Thermo-brachytherapy Seed for Treatment of Solid Tumors (opens in a new tab)

  9. DOSIMETRIC STUDY OF BETA-MINUS EMITTER PRASEODYMIUM-142 : APPLICATIONS IN MICROSPHERE BRACHYTHERAPY FOR HEPATOCELLULAR CARCINOMA AND BRACHYTHERAPY FOR OCULAR SQUAMOUS CELL CARCINOMA

    A dosimetric study of the beta-minus emitter Praseodymium-142 (¹⁴²Pr) was performed and two main innovative applications of this source in brachytherapy are proposed: microsphere brachytherapy and eye plaque brachytherapy. ¹⁴²Pr (96.3% beta and 3.7% gamma) has recently gained increased attention …

    ecu Repository record for DOSIMETRIC STUDY OF BETA-MINUS EMITTER PRASEODYMIUM-142 : APPLICATIONS IN MICROSPHERE BRACHYTHERAPY FOR HEPATOCELLULAR CARCINOMA AND BRACHYTHERAPY FOR OCULAR SQUAMOUS CELL CARCINOMA (opens in a new tab)

  10. Volumetric modulated Arc Therapy versus 3D conformal radiotherapy in the treatment of locally advanced cervical cancer. A single institution, comparative dosimetric study

    … in the management of LACC. Aim: To compare dosimetric parameters between VMAT and 3D-CRT in the management of LACC. Setting: The study analysed patients treated at Groote Schuur Hospital between May and December 2017. Method: A non-randomized comparative retrospective study. EBRT plans for …

    cape-town Repository record for Volumetric modulated Arc Therapy versus 3D conformal radiotherapy in the treatment of locally advanced cervical cancer. A single institution, comparative dosimetric study (opens in a new tab)

  11. Volumetric Modulated Arc Therapy Evaluation With The Radiological Physics Center Head and Neck Phantom

    … in terms of both treatment plan quality and dosimetric delivery accuracy using the Radiological Physics Center (RPC) head and neck (H&N) phantom. Clinically relevant treatment plans were created for the phantom using typical prescription and dose constraints for Elekta VMAT (planned with …

    uthsc Repository record for Volumetric Modulated Arc Therapy Evaluation With The Radiological Physics Center Head and Neck Phantom (opens in a new tab)

  12. Dosimetric comparison of volumetric modulated arc therapy and three dimensional conformal radiotherapy in the adjuvant setting for the management of gastric cancer : target volume coverage and normal tissue sparing

    Whilst the benefit of adjuvant radiotherapy in gastric cancer is known, the optimal means of delivery, including two dimensional conventional, three dimensional conformal radiotherapy, intensity modulated radiotherapy and volumetric modulated arc therapy is less certain. The purpose of this study …

    cape-town Repository record for Dosimetric comparison of volumetric modulated arc therapy and three dimensional conformal radiotherapy in the adjuvant setting for the management of gastric cancer : target volume coverage and normal tissue sparing (opens in a new tab)

  13. Integration of VMC++ into a Commercial Treatment Planning System

    … 1x1 cm2. Geometric validation was successful. Dosimetric validation was performed with respect to DOSXYZnrc on a water phantom, resulting in agreement within statistical uncertainty except for slight differences at the surface of the phantom. Dosimetric comparison was made for a head-and-neck …

    vcu Repository record for Integration of VMC++ into a Commercial Treatment Planning System (opens in a new tab)

  14. Development of 3D-Printed Patient Specific Bolus For Clinical Use In to tal Scalp Irradiation

    … to the head phantom for both bolus caps, and dosimetric validation was performed using thermoluminescent dosimeters (TLD). The resulting 3D-printed bolus caps had excellent conformality to the phantom scalp, with air gaps of less than 4 mm. Dosimetric measurements demonstrated the bolus caps …

    uthsc Repository record for Development of 3D-Printed Patient Specific Bolus For Clinical Use In to tal Scalp Irradiation (opens in a new tab)

  15. Accelerator-Based Neutron Branchytherapy

    … 150 Watts. The insertion length is 10 cm. The dosimetric characteristics were simulated using the Monte Carlo code MCNP and the treatment times were then calculated for a given heat load. The simulations and calculations show that the fast neutron dose is the dominant dose component for all the …

    mit Repository record for Accelerator-Based Neutron Branchytherapy (opens in a new tab)

  16. Automated to ols for Contour Review in Radiotherapy

    … examined the relationship between geometric and dosimetric agreement metrics amongst normal tissue auto-contours and clinical contours in discerning whether the current state of automated contour QA (which mainly relies on geometric comparisons) was appropriately defining contour errors and …

    uthsc Repository record for Automated to ols for Contour Review in Radiotherapy (opens in a new tab)

Page 1 of 5