Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 25 for “"dog bone"”.

  1. Ceramic Implants in Dog Bone

    Made available in DSpace on 2014-12-11T21:33:42Z (GMT). No. of bitstreams: 1 7121231.pdf: 4709422 bytes, checksum: 97e403961de3653a60003ed4c9954caf (MD5) Previous issue date: 1971

    uiuc Repository record for Ceramic Implants in Dog Bone (opens in a new tab)

  2. Tensile relaxation of bonded concrete overlays

    … and tensile relaxation tests were done on dog-bone concrete mortar specimens.

    cape-town Repository record for Tensile relaxation of bonded concrete overlays (opens in a new tab)

  3. Design of fixtures and specimens for high strain-rate tensile testing on a drop tower

    … analysis. The design selected used a double dog-bone specimen bent into a "U"-shape and impacted by a weighted force sensor with a steel tup attached to the bottom. The appropriate fixtures were designed. Future work on this project includes manufacturing of the fixtures, design and …

    mit Repository record for Design of fixtures and specimens for high strain-rate tensile testing on a drop tower (opens in a new tab)

  4. Matrix-fiber stress transfer in composite materials elasto-plastic model with an interphase layer

    … interaction was studied experimentally using dog-bone samples that contained seven fibers forming an hexagonal pattern.

    vt Repository record for Matrix-fiber stress transfer in composite materials elasto-plastic model with an interphase layer (opens in a new tab)

  5. Quantitative Comparison: Equine Genital Tissues Under Uniaxial Loading

    … obtained via digital image correlation. Dog-bone-shaped tissue specimens were excised from mares and geldings (n=23 from female tissues and n=42 from male tissues) with all specimens aligned along the circumferential direction (CD) of the vagina, penis, and scrotum. The results include …

    vt Repository record for Quantitative Comparison: Equine Genital Tissues Under Uniaxial Loading (opens in a new tab)

  6. Fracture and plasticity characterization of DH-36 Navy steel

    … tests were performed, including tensile tests on dog-bone and notched specimens and punch indentation tests on circular blanks. Also, tensile and shear tests were performed on butterfly specimens using the dual actuator loading frame. Fracture surface strains were measured using digital image …

    mit Repository record for Fracture and plasticity characterization of DH-36 Navy steel (opens in a new tab)

  7. Relationship between Fatigue Properties and Surface Treatment of Aluminum Alloy

    … and 6014 sheet metal. The testing employed dog bone samples with a servo fatigue test rig, utilizing the staircase fatigue method. The study also delved into crack formation and microstructural characteristics of cross-sections to investigate failure modes. The results of this investigation …

    chalmers Repository record for Relationship between Fatigue Properties and Surface Treatment of Aluminum Alloy (opens in a new tab)

  8. Processing and properties of recycled aggregate concrete

    … various mixture batches. In addition, ring and dog bone tests were studied when the specimen is restrained and is affected by internal tensile stress. With using 74% initial moisture states of recycled coarse aggregates, the compressive strength was similar to that of normal concrete and the …

    uiuc Repository record for Processing and properties of recycled aggregate concrete (opens in a new tab)

  9. Effect of Postmortem Time and Preservation Fluid on the Tensile Material Properties of Bovine Liver Parenchyma

    … blocks, or slices of tissue. Multiple parenchyma dog-bone samples from each liver were tested once to failure at three time points: ~6hrs, ~24hrs, and ~48hrs postmortem. The data were then analyzed to determine if there were significant changes in the material properties with respect to postmortem …

    vt Repository record for Effect of Postmortem Time and Preservation Fluid on the Tensile Material Properties of Bovine Liver Parenchyma (opens in a new tab)

  10. Effect of high velocity oxy-fuel (HVOF) coatings on fatigue behaviour of carbon steel

    … out with a strain rate of 0.5 mm/min and a dog bone shaped specimen in accordance with ASTM-E8 standard. Fatigue test was performed under the stress ratio, R = -1 in accordance with ASTM-E466 by tension-compression cyclic loading (sine wave) with a frequency of 20 Hz. The results showed that …

    uthm Repository record for Effect of high velocity oxy-fuel (HVOF) coatings on fatigue behaviour of carbon steel (opens in a new tab)

  11. Fretting fatigue Behaviour of Inconel 718 at room and high Temperature

    … used, consisting of a rectangular cross-section "dog-bone" specimen pressed against a cylindrical pad. The setup was assembled using a device commonly referred to as a “fretting bridge.” Both plain fatigue and fretting fatigue tests were carried out under different levels of axial and normal load, …

    sevilla Repository record for Fretting fatigue Behaviour of Inconel 718 at room and high Temperature (opens in a new tab)

  12. High-Strain Rate Tensile Characterization Of Graphite Platelet Reinforced Vinyl Ester Based Nanocomposites Using Split-Hopkinson Pressure Bar

    … investigations conducted using the traditional dog-bone specimen in quasi-static direct tensile tests. Investigation of both quasi-static and dynamic indirect tensile test responses show the strain rate effect on the tensile strength and energy absorbing capacity of the candidate materials. …

    mississippi Repository record for High-Strain Rate Tensile Characterization Of Graphite Platelet Reinforced Vinyl Ester Based Nanocomposites Using Split-Hopkinson Pressure Bar (opens in a new tab)

  13. STABLE ISOTOPIC INSIGHTS INTO THE SUBSISTENCE PATTERNS OF PREHISTORIC DOGS (CANIS FAMILIARIS) AND THEIR HUMAN COUNTERPARTS IN NORTHEASTERN NORTH AMERICA

    … first is to investigate the diet of prehistoric dogs (Canis familiaris) in the Northeast region of North America using stable isotope analysis. The second goal of this study is to generate independent data concerning the presence or absence of C4 resources, such as maize, in the diets of dogs. …

    temple Repository record for STABLE ISOTOPIC INSIGHTS INTO THE SUBSISTENCE PATTERNS OF PREHISTORIC DOGS (CANIS FAMILIARIS) AND THEIR HUMAN COUNTERPARTS IN NORTHEASTERN NORTH AMERICA (opens in a new tab)

  14. Effects of Alkali-Silica Reaction on Response of Concrete Squat Shear Walls

    … (MOR) beams, three expansion prisms, and six dog-bone specimens. To accel¬erate the ASR and deterioration of the concrete, the walls were stored in an environmental chamber, specially constructed with the capacity to store large specimens in a controlled high-temperature and high-humidity …

    toronto-retro Repository record for Effects of Alkali-Silica Reaction on Response of Concrete Squat Shear Walls (opens in a new tab)

  15. The Mechanical Thermal and Microstructural Behaviors of the Strip Silicates Reinforced Epoxy-based Nanocomposites

    … by mechanical stirring and then casting to mold dog-bone shape samples for tensile and other tests. A gradual trend of changes upon mechanical, thermal and microstructural behaviors were investigated. Introduction of strip silicates inside the epoxy matrix contributed to higher tensile strength, …

    uno Repository record for The Mechanical Thermal and Microstructural Behaviors of the Strip Silicates Reinforced Epoxy-based Nanocomposites (opens in a new tab)

  16. Material Properties of Human Rib Cortical Bone from Dynamic Tension Coupon Testing

    … material properties of human rib cortical bone using dynamic tension coupon testing. This study presents 117 human rib cortical bone coupon tests from six cadavers, three male and three female, ranging in age from 18 to 67 years old. The rib sections were taken from the anterior, lateral, …

    vt Repository record for Material Properties of Human Rib Cortical Bone from Dynamic Tension Coupon Testing (opens in a new tab)

  17. A Study of Durability for Elastomeric Fuel Cell Seals and an Examination of Confinement Effects in Elastomeric Joints

    … and strain at failure were determined using dog-bone samples aged at several different imposed strains and aging times in environments of interest. Tearing energy was evaluated using trouser test samples tested under different rates and temperatures after various environmental aging …

    vt Repository record for A Study of Durability for Elastomeric Fuel Cell Seals and an Examination of Confinement Effects in Elastomeric Joints (opens in a new tab)

  18. Seismic Performance of Square Nickel-Titanium Reinforced ECC Columns with Headed Couplers

    … fact that the entire bar section rather than a dog bone shape is utilized. Analytical studies conducted using OpenSees consisted of developing models for the three column models. The analytical models were validated by comparing the results with the experimental data. The models were then used …

    unr Repository record for Seismic Performance of Square Nickel-Titanium Reinforced ECC Columns with Headed Couplers (opens in a new tab)

  19. Surface Orientation Dependent Corrosion Damage and Temperature Dependent Mechanical Property Degradation of Sensitized AA5083-H116 Alloys

    … Novelis 5083-H116 was sensitized at 100°C; dog bone samples were created and exposed for two years in a beach environment to investigate possible sensitization and corrosion effects. It was found that the sensitization at 100°C and 150°C of Alcoa 5083-H116 led to recrystallization from the …

    vt Repository record for Surface Orientation Dependent Corrosion Damage and Temperature Dependent Mechanical Property Degradation of Sensitized AA5083-H116 Alloys (opens in a new tab)

  20. Effects of Electrically-Stimulated Silver-Coated Implants and Bacterial Contamination in a Canine Radius Fracture Gap Model

    … mature canines weighing 19.2-23.2 kg were used. Dogs were randomly assigned to into control and contaminated groups. A 5 mm ostectomy gap was made in both radii of each dog. One radius of each dog was stabilized with a silver-coated stainless steel bone plate and the other with an uncoated …

    vt Repository record for Effects of Electrically-Stimulated Silver-Coated Implants and Bacterial Contamination in a Canine Radius Fracture Gap Model (opens in a new tab)

Page 1 of 2