Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"cr-39"”.

  1. A Computerized Image Analysis System for the SSNTD CR-39

    Made available in DSpace on 2017-07-06T18:42:31Z (GMT). No. of bitstreams: 3 Briggs_Stephen_J_MS.pdf: 33415726 bytes, checksum: de5e59dbbe863b620fe21c74e9fd9fb8 (MD5) Briggs_Stephen_J_MS_ABS.pdf: 957747 bytes, checksum: 4750bd0e85e1075f626da29472a3bef7 (MD5) license.txt: 4813 bytes, checksum: …

    uiuc Repository record for A Computerized Image Analysis System for the SSNTD CR-39 (opens in a new tab)

  2. Implementation of scattering pinhole diagnostic for detection of fusion products on CR-39 at high particle fluence

    … use solid-state nuclear track detector CR-39 as a means to detect different types of nuclear products. Until recently, it was difficult to use CR-39 in experiments with very high yields because particle tracks would overlap. A scattering pinhole has been implemented in order to reduce …

    mit Repository record for Implementation of scattering pinhole diagnostic for detection of fusion products on CR-39 at high particle fluence (opens in a new tab)

  3. Use of the SSNTD CR-39 and Automated Image Analysis as Applied to Dosimetry for Fast Neutron Therapy

    … (GMT). No. of bitstreams: 3 Wepprecht_Craig_S_MS.pdf: 22438733 bytes, checksum: 28128907fb138ea8eeeb735694cd8242 (MD5) Wepprecht_Craig_S_MS_ABS.pdf: 464394 bytes, checksum: 7b784505c5f449545a8cb09c5c918196 (MD5) license.txt: 4813 bytes, checksum: 715c4321821a960fa1a1e91d2ac7ebce (MD5) …

    uiuc Repository record for Use of the SSNTD CR-39 and Automated Image Analysis as Applied to Dosimetry for Fast Neutron Therapy (opens in a new tab)

  4. Development of the Solid State Nuclear Track Detector CR-39 as a Microdosimeter for High Energy Neutron Cancer Therapy

    Made available in DSpace on 2017-07-06T18:38:08Z (GMT). No. of bitstreams: 3 Durham_James_S_PhD.pdf: 309754682 bytes, checksum: 4eecbbdb6ea0eda6c19c601e5f983659 (MD5) Durham_James_S_PhD_ABS.pdf: 1292789 bytes, checksum: 5eb2a18d28c44695e61b632b8f9e8976 (MD5) license.txt: 4813 bytes, checksum: …

    uiuc Repository record for Development of the Solid State Nuclear Track Detector CR-39 as a Microdosimeter for High Energy Neutron Cancer Therapy (opens in a new tab)

  5. Dosimetry with CR-39 in Tissue Equivalent Liquid for a Proton (43 MEV) Beryllium and Deuteron (25 MEV) Beryllium Neutron Beam

    Made available in DSpace on 2017-07-06T18:48:50Z (GMT). No. of bitstreams: 3 Jimenez_Javier_R_MS.pdf: 26930537 bytes, checksum: 59b9118e60458ab2a317df0d9c955882 (MD5) Jimenez_Javier_R_MS_ABS.pdf: 560299 bytes, checksum: bf70a30676a505cf597db8a59a2e9dbf (MD5) license.txt: 4813 bytes, checksum: …

    uiuc Repository record for Dosimetry with CR-39 in Tissue Equivalent Liquid for a Proton (43 MEV) Beryllium and Deuteron (25 MEV) Beryllium Neutron Beam (opens in a new tab)

  6. An In Vitro Measured Enhancement of the Absorbed Dose in B-10 Assisted Fast Neutron Cancer Therapy using the Solid state Nuclear Track Detector CR-39

    Made available in DSpace on 2017-07-06T18:55:06Z (GMT). No. of bitstreams: 3 Less_Timmy_J_MS.pdf: 29842925 bytes, checksum: 0edf54027e5d6b0659ddc0f728bb1c58 (MD5) Less_Timmy_J_MS_ABS.pdf: 1061592 bytes, checksum: 84927eb19cf1fca5b87eb3a9b76516a7 (MD5) license.txt: 4813 bytes, checksum: …

    uiuc Repository record for An In Vitro Measured Enhancement of the Absorbed Dose in B-10 Assisted Fast Neutron Cancer Therapy using the Solid state Nuclear Track Detector CR-39 (opens in a new tab)

  7. Impact of x-ray dose on the response of CR-39 nuclear track detector to 1-5.5 MeV alphas and 0.5-9.1 MeV protons for spectroscopy at the OMEGA Laser Facility and the National Ignition Facility

    The CR-39 nuclear track detector is used in many nuclear diagnostics fielded at inertial confinement fusion (ICF) facilities. Large x-ray fluences generated by ICF experiments may impact the CR-39 response to incident charged particles. To determine the impact of x-ray exposure on the CR-39

    mit Repository record for Impact of x-ray dose on the response of CR-39 nuclear track detector to 1-5.5 MeV alphas and 0.5-9.1 MeV protons for spectroscopy at the OMEGA Laser Facility and the National Ignition Facility (opens in a new tab)

  8. 157nm F₂laser characterization and application to polymer ablation

    … polyethylene (UHMWPE), Lexan polycarbonate and CR-39 polymer have been investigated. The main priority was given to Lexan polycarbonate and CR-39 polymer as new potential materials to explore using this laser.A considerable component of the work is directed at gaining a better understanding of …

    hull Repository record for 157nm F₂laser characterization and application to polymer ablation (opens in a new tab)

  9. An improved method for measuring the absolute DD neutron yield and calibrating neutron time-of-flight detectors in inertial confinement fusion experiments

    … balance of the reaction is net positive. This criterion is often referred to as ignition. One of the most common metrics for gauging progress towards ignition in an ICF implosion is the ITFX parameter (similar to the Lawson Criterion) and is primarily a function of the implosion areal density …

    mit Repository record for An improved method for measuring the absolute DD neutron yield and calibrating neutron time-of-flight detectors in inertial confinement fusion experiments (opens in a new tab)

  10. Imaging the burn region of laser driven implosions on OMEGA using the proton core imaging spectroscope

    … Proton Core Imaging Spectroscope (PCIS). Using CR-39 nuclear track detectors, PCIS applies the technique of penumbral imaging to measure the radial profile of D-D and D-3He protons produced by implosions of D2-3He-filled capsules. For capsules with 20 [mu]m-CH shells, images of D-3He protons …

    mit Repository record for Imaging the burn region of laser driven implosions on OMEGA using the proton core imaging spectroscope (opens in a new tab)

  11. Development of techniques for high-resolution spatially-resolved elemental analysis in materials of interest in luminescence dating

    … using solid state nuclear track detectors (CR-39) were applied initially to map localised differences in surface alpha activity, and were subsequently developed to provide semi-quantitative data about the concentration of alpha emitters present, and by association, the likely concentrations …

    durham Repository record for Development of techniques for high-resolution spatially-resolved elemental analysis in materials of interest in luminescence dating (opens in a new tab)

  12. Indoor atmospheric radon in Hamadan, Iran. Atmospheric radon indoors and around Hamadan city in Iran.

    … monitored using track-etch detectors of type CR-39 exposed for three month periods. The arithmetic mean radon concentration in Hamadan buildings was determined to be 80 Bqm-3 and also an average indoor annual effective dose equivalent for the Hamadan city population was calculated as 1.5 mSv. …

    bradford Repository record for Indoor atmospheric radon in Hamadan, Iran. Atmospheric radon indoors and around Hamadan city in Iran. (opens in a new tab)

  13. Rayleigh-Taylor-Induced electromagnetic fields in laser-produced plasmas

    … Proton fluence distributions were recorded on CR-39 detectors and Fourier analyzed to infer path-integrated field strengths. Rayleigh-Taylor (RT) growth of preimposed surface perturbations generated magnetic fields by the RT-induced Biermann battery and were measured for the first time. Good …

    mit Repository record for Rayleigh-Taylor-Induced electromagnetic fields in laser-produced plasmas (opens in a new tab)

  14. Using fusion-product spectroscopy to diagnose inertial confinement fusion implosions and study stopping power on OMEGA, the NIF, and Z

    … and long neutron burn widths. For this reason, a CR-39 based neutron-recoil spectrometer has been developed for measuring the DD spectrum at the Z. A proof of principle design was fielded and the data is presented. A improved shielded design for accurately measuring the liner areal density is also …

    mit Repository record for Using fusion-product spectroscopy to diagnose inertial confinement fusion implosions and study stopping power on OMEGA, the NIF, and Z (opens in a new tab)

  15. An experimental investigation of low energy nuclear reactions in a DC glow discharge

    Submission published under a 24 month embargo labeled 'U of I Access', the embargo will last until 2024-05-01

    uiuc Repository record for An experimental investigation of low energy nuclear reactions in a DC glow discharge (opens in a new tab)