  1. Dynamic identification of the Augusta hybrid base isolated building using data from full scale push and sudden release tests

    A three-story reinforced concrete building in Augusta (IT), isolated at the base and designed according to the provisions of the latest Italian seismic regulations, was subjected to a series of push and sudden release tests in March 2013. The Augusta isolation system is hybrid, consisting of 16 …

    catania Repository record for Dynamic identification of the Augusta hybrid base isolated building using data from full scale push and sudden release tests (opens in a new tab)

  2. On the performance of base-isolated buildings: a generic model

    … traffic propagates through the ground and into buildings, resulting in unacceptable levels of internal noise and vibration. A common solution to this increasingly significant problem is the base-isolation of buildings by incorporating vibration isolation bearings between the buildings and their …

    cambridge Repository record for On the performance of base-isolated buildings: a generic model (opens in a new tab)

  3. Multi-resonant Electromagnetic Shunt in Base Isolation for Vibration Damping and Energy Harvesting

    … induced vibrations of low- or mid-rise buildings, and at the same time to efficiently harvest utility-scale energy by using an optimally configured multi-resonant electromagnetic shunt in base isolation. In this research, two multi-resonant shunt configurations, parallel and series, were …

    vt Repository record for Multi-resonant Electromagnetic Shunt in Base Isolation for Vibration Damping and Energy Harvesting (opens in a new tab)

  4. A performance-based design framework for base-isolated buildings against ground-borne vibration

    \noindent Ground-borne vibration in buildings is a recurrent design concern for new developments in the vicinity of surface or underground railways, a common question being whether or not a building necessitates some form of vibration mitigation. This question is commonly tackled by comprehensive …

    cambridge Repository record for A performance-based design framework for base-isolated buildings against ground-borne vibration (opens in a new tab)

  5. Development of Electromagnetic Friction Dampers for Improving Seismic Performance of Civil Structures

    … affect the seismic response of a multi-story base-isolated building as it undermines the seismic isolation system by inserting high-frequency pulses into the floor acceleration. This may pump a considerable portion of the seismic input energy into higher modes, resulting in the increase of the …

    cuny Repository record for Development of Electromagnetic Friction Dampers for Improving Seismic Performance of Civil Structures (opens in a new tab)