  1. Investigation of Inflection Points as Brace Points in Multi-Span Purlin Roof Systems

    … Seven tests were conducted using "C" and "Z" purlins attached to standing seam and through fastened panels. These tests were subjected to uniform gravity loading by means of a vacuum chamber. The experimental results were compared with analytical predictions based on the 1996 AISI …

    vt Repository record for Investigation of Inflection Points as Brace Points in Multi-Span Purlin Roof Systems (opens in a new tab)

  2. Cold-Formed Steel Behavior: Elastic Buckling Simplified Methods for Structural Members with Edge-Stiffened Holes and Purlin Distortional Buckling Strength Under Gravity Loading

    … determining capacity, in most loading conditions purlins are subjected to a downward uniform loading that provides additional resistance to distortional buckling in the top flange beyond the resistance of the steel roofing panel. This research describes an experimental study to explore and …

    vt Repository record for Cold-Formed Steel Behavior: Elastic Buckling Simplified Methods for Structural Members with Edge-Stiffened Holes and Purlin Distortional Buckling Strength Under Gravity Loading (opens in a new tab)

  3. Experimental Determination of Required Lateral Restraint Forces for Z-Purlin Supported, Sloped Metal Roof Systems

    … span and multiple span metal roof systems. Z-purlins were used extensively with through-fastened and standing seam roof panel. Two, four, and six purlin lines were used for the single span tests while only four purlin lines were used for the multiple span tests. Restraint forces were measured …

    vt Repository record for Experimental Determination of Required Lateral Restraint Forces for Z-Purlin Supported, Sloped Metal Roof Systems (opens in a new tab)

  4. Lateral Restraint Brace Forces in Quarter Point and Third Point Plus Support Braced Z-Purlin Supported Roof Systems Subject to Gravity Load

    The objective of this study was to develop design equations that predict lateral restraint forces in two commonly used Z-purlin supported roof systems. These are quarter point bracing and third point plus support bracing. To that end, a stiffness model used in the past has been reintroduced. This …

    vt Repository record for Lateral Restraint Brace Forces in Quarter Point and Third Point Plus Support Braced Z-Purlin Supported Roof Systems Subject to Gravity Load (opens in a new tab)