Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"Vernier"”.

  1. Design of a Vernier Permanent Magnet Wind Generator

    … demand for low-speed direct-drive machines. The Vernier machine has inherent properties such as high torque density, sinusoidal induced voltages and low torque ripple which makes it suitable for low-speed direct-drive wind applications. Additionally, its mechanical structure is as simple as a …

    cape-town Repository record for Design of a Vernier Permanent Magnet Wind Generator (opens in a new tab)

  2. Design and analysis of a compact high-torque permanent magnet vernier machine for a portable MRI system

    Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2025-10-20 without embargo terms

    uiuc Repository record for Design and analysis of a compact high-torque permanent magnet vernier machine for a portable MRI system (opens in a new tab)

  3. Behavioral measurements of visual processing in adult male and female hooded rats: Do visual tasks reflect sex differences in visual cortex morphology?

    … Three types of visual functions--grating acuity, vernier acuity, and motion parallax information--that are processed in the primary visual cortex were examined. Grating acuity was measured in a forced choice Y-maze and a jumping stand. Using a criterion of 34 correct/50 trials, grating acuity for …

    uiuc Repository record for Behavioral measurements of visual processing in adult male and female hooded rats: Do visual tasks reflect sex differences in visual cortex morphology? (opens in a new tab)

  4. Interferometric Synthetic Aperture Sonar Signal Processing for Autonomous Underwater Vehicles Operating Shallow Water

    … to form a SAS image, an interferometric Vernier method to unwrap the phase; and confirming the direction of arrival with the MUltiple SIgnal Channel (MUSIC) estimation technique. The fusion of Chirp-Scaling, Vernier, and MUSIC lead to the stability in the bathymetric height measurement, …

    uno Repository record for Interferometric Synthetic Aperture Sonar Signal Processing for Autonomous Underwater Vehicles Operating Shallow Water (opens in a new tab)

  5. (VDL)² : a jitter measurement built-in self-test circuit for phase locked loops

    … loops. The (VDL)2, which stands for Variable Vernier Digital Delay Locked Line, implements both cycle-to-cycle and phase jitter measurements, by using a digital delay locked loop and a 60 stage Vernier delay line. This achieves a nominal jitter resolution of 10 ps with a capture range of +/- …

    mit Repository record for (VDL)² : a jitter measurement built-in self-test circuit for phase locked loops (opens in a new tab)

  6. The Dark Focus of Visual Accommodation: Its Existence, Its Effects, Its Measurement

    … Experiment I, a new optometer -- the polarized vernier optometer -- is described and compared experimentally to the better-known laser optometer. The former compared favorably to the latter in terms of subject acceptability and agreement of dark focus measurements.

    uiuc Repository record for The Dark Focus of Visual Accommodation: Its Existence, Its Effects, Its Measurement (opens in a new tab)

  7. Design of a fluidic test bed for MEMS piezoelectric energy harvester

    … and designing it around dimensional analysis, a Vernier Low-g accelerometer is used to measure the vibration spectrum. The frequency that was analyzed was 251.01 ± 0.447 Hz and when converted back to the Alaskan pipeline we achieved a frequency of 6.94Hz. Using this information we can design PMPG …

    mit Repository record for Design of a fluidic test bed for MEMS piezoelectric energy harvester (opens in a new tab)

  8. Design and thermal modeling of a residential building

    … heater and five temperature sensors connected to Vernier LabPro for data acquisition. Comparison between scale model prediction and experimental result shows similarity in steady state values for temperature and characteristic heating/cooling time constants. This thesis is an important first step …

    mit Repository record for Design and thermal modeling of a residential building (opens in a new tab)

  9. ΣΥΜΒΟΛΗ ΣΤΗ ΜΕΛΕΤΗ ΤΗΣ ΓΡΑΜΜΙΚΗΣ ΣΥΣΤΟΛΗΣ ΤΩΝ ΑΛΓΙΝΙΚΩΝ ΑΠΟΤΥΠΩΤΙΚΩΝ ΥΛΙΚΩΝ

    … THE MEASUREMENTS WERE MADE WITH A LINEAR VERNIER MICROSCOPE CAPABLE OF MEASURING TO 0,01 MM THE INITIAL MEASUREMENT WAS MADE 10 MIN FROM THE START OF MIXING. FURTHER STUDIES WERE TAKEN AT 30 MIN, 1,2,3 AND 24 HOURS FROM THE START OF MIXING. 12 SPECIMENS WERE MADE FOR EACH OF THE ABOVE …

    greece Repository record for ΣΥΜΒΟΛΗ ΣΤΗ ΜΕΛΕΤΗ ΤΗΣ ΓΡΑΜΜΙΚΗΣ ΣΥΣΤΟΛΗΣ ΤΩΝ ΑΛΓΙΝΙΚΩΝ ΑΠΟΤΥΠΩΤΙΚΩΝ ΥΛΙΚΩΝ (opens in a new tab)

  10. Parity-Time Symmetry in Lasers and Optoelectronic Oscillators

    … be achieved by combining PT symmetry with the Vernier effect. Chapter 5 introduces a dual-loop PT-symmetric fiber laser with a rational loop-length ratio, which drastically reduces mode density and improves mode selectivity. Experiments confirm single-mode lasing with a record SMSR of 53.2 dB …

    ottawa-retro Repository record for Parity-Time Symmetry in Lasers and Optoelectronic Oscillators (opens in a new tab)

  11. Perception and Eye Alignment Control: Do People Think the Same Way Their Brain Thinks?

    … contrast. A similar effect occurs for motion and vernier thresholds when the target components being compared have different contrast. The effect occurs especially for middle and low spatial frequencies. This study compares observers’ stereoscopic depth perception with vertical disparity vergence …

    houston Repository record for Perception and Eye Alignment Control: Do People Think the Same Way Their Brain Thinks? (opens in a new tab)

  12. Model for the design and implementation of reliable and cost effective ISO 9000 quality control systems

    … months, in-house training/formal training and vernier/micrometer are determined based on experience and research of the manufacturing process and available inspection techniques. A series of experiments are carried out to obtain the best combination of factors and levels that confirm that the …

    concordia Repository record for Model for the design and implementation of reliable and cost effective ISO 9000 quality control systems (opens in a new tab)

  13. Utilização de um ambiente virtual para o ensino de leis de Ohm no ensino básico

    … com auxílio de outro aplicativo, denominado Vernier graphical analysis. Nossa proposta inclui também um questionário de avaliação dos conhecimentos prévios dos alunos acerca de eletricidade. Para avaliação final da sequência é proposto um questionário a ser respondido pelos alunos segundo o …

    brazil-uff Repository record for Utilização de um ambiente virtual para o ensino de leis de Ohm no ensino básico (opens in a new tab)

  14. Atomic emission misconceptions as investigated through student interviews and measured by the Flame Test Concept Inventory

    … in undergraduate laboratories. Two MCA systems, Vernier and MeasureNet, were used in two unique experiments demonstrating the detection of salicylate in aspirin tablets by FIA and the LC separation of a mixture of riboflavin and fluorescein. Both instruments are rugged and inexpensive permitting …

    ohiolink Repository record for Atomic emission misconceptions as investigated through student interviews and measured by the Flame Test Concept Inventory (opens in a new tab)

  15. Computer-related technology use in the high school physics classroom: a case study

    … High School Adaptation videotapes, videodiscs, Vernier and Pasco probeware, and software which included Interactive Physics II™, Physics Explorer, ClarisWorks, and CA Cricket Graph. A ratio of 3 students to 1 computer allowed groups of students to engage actively in the learning process. The …

    vt Repository record for Computer-related technology use in the high school physics classroom: a case study (opens in a new tab)

  16. Limb scatter measurements of high altitude cloud distributions

    … an Asian Tropopause Aerosol Layer in support of Vernier et al. (2011). Finally, the technique is used to track the dispersion and evolution of the volcanic plume following the Sarychev eruption in June 2009 since monitoring volcanic plumes is an effective way to help mitigate aviation hazards.

    sask Repository record for Limb scatter measurements of high altitude cloud distributions (opens in a new tab)

  17. Top-Down Control of Lateral Interactions in Visual Cortex

    … of parallel lines increased LFP coherence while vernier task involving segregation of collinear line decrease LFP coherence. Also, grouping of collinear lines to detect a contour resulted in increased LFP interactions. Since noise correlations can affect the coding accuracy of a cortical network, …

    rockefeller Repository record for Top-Down Control of Lateral Interactions in Visual Cortex (opens in a new tab)

  18. Adaptation of VT-Dbr Lasers for LIDAR

    <p>Vernier Tuned Distributed Bragg Reflector (VT-DBR) lasers have had great success in the field of Swept-Source Optical Coherence Tomography (SS-OCT) due to their continuous and nearly 40 nm wavelength tuning range in a single longitudinal mode. Fast sweeps allow for real time imaging with …

    calpoly Repository record for Adaptation of VT-Dbr Lasers for LIDAR (opens in a new tab)

  19. Mode I and Mode II Measurements For Stiction Failed Micro-Electro-Mechanical Systems

    … Deflection of the spring is measured with the vernier scale of the actuator. Then a nonlinear elastic model for the fix—fix beam flexure is used to determine the interfacial adhesion energy between the failed microcantilever beam and the surface. A theory is developed to measure the strain …

    unm Repository record for Mode I and Mode II Measurements For Stiction Failed Micro-Electro-Mechanical Systems (opens in a new tab)

Page 1 of 2