Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"Ventilators"”.

  1. Optimising the airflow performance of ventilators for natural ventilation in buildings.

    … slots fabricated from pine wood to commercial ventilators and mesh-screens as are commonly found in natural ventilation applications. The results of this investigation indicate that the overall airflow properties of a ventilator are influenced by the combination of constituent components, the …

    sheffield-hallam Repository record for Optimising the airflow performance of ventilators for natural ventilation in buildings. (opens in a new tab)

  2. An investigation of the performance of a stationary siphoning type of roof ventilator

    … across the open end of the stack. Stacks and ventilators of sizes 10, 12, 14, 16, 18, 20, and 24 inches were tested. All test results are based on zero difference in temperature between the wind tunnel air and the stack air and on no friction loss in the stack. The capacities listed are for …

    vt Repository record for An investigation of the performance of a stationary siphoning type of roof ventilator (opens in a new tab)

  3. An investigation into turbine ventilators as a potential environmental control measure to minimise the risk of transmission of tuberculosis - a laboratory and field study

    TB is an airborne infectious disease which is spread by droplet nuclei, carrying Mycobacterium tuberculosis, in the air. The droplet nuclei small enough to enter human respiratory pathways are 1-5 μm in size and are able to travel long distances (Hodgson, et al., 2009) (WHO, 1999), and can be …

    cape-town Repository record for An investigation into turbine ventilators as a potential environmental control measure to minimise the risk of transmission of tuberculosis - a laboratory and field study (opens in a new tab)

  4. Natural ventilation in buildings: the development of a component

    Wind activated rooftop ventilators have recently been rediscovered as appropriate energy conserving alternatives and/or supplements to power ventilation. Designers of passive solar heating/ cooling systems, for instance, often use ventilators in various ways as important components of their …

    vt Repository record for Natural ventilation in buildings: the development of a component (opens in a new tab)

  5. A European survey of Non- Invasive Ventilation (NIV)

    … among Pulmonologists, and in AHRF. Dedicated NIV ventilators and ICU ventilators with NIV modules are preferably used in AHRF and in de-novo hypoxic respiratory failure, respectively, together with oro-nasal masks.

    catania Repository record for A European survey of Non- Invasive Ventilation (NIV) (opens in a new tab)

  6. Oral Mucosal Microcirculation in the Context of Endotracheal Tube-Related Pressure Ulcer Development

    … medical devices such as cardiac monitors, ventilators, non-invasive positive pressure ventilators, nasal gastric tubes (NG), orogastric tubes (OG), and urinary tract catheters. Nurses are challenged to prevent hospital acquired pressure ulcers (HAPUs) because many of these devices can cause …

    hawaii Repository record for Oral Mucosal Microcirculation in the Context of Endotracheal Tube-Related Pressure Ulcer Development (opens in a new tab)

  7. Most Effective Nursing Interventions to Prevent Central Line-Associated Bloodstream Infections: A Critical Review of the Literature

    … used in medical procedures, such as catheters or ventilators (Centers for Disease Control and Prevention, 2014). HAIs monitored by the CDC include central line-associated bloodstream infections (CLABSIs), catheter-associated urinary tract infections (CAUTIs), ventilator associated pneumonia (VAP), …

    brockport Repository record for Most Effective Nursing Interventions to Prevent Central Line-Associated Bloodstream Infections: A Critical Review of the Literature (opens in a new tab)

  8. The windcatchers of Yazd

    … in the houses of Yazd, as airconditioners and ventilators, are investigated. General temperature limits o-F their summer performance in the context of the life-style of the Yazdi, are established and reviewed in relation to comfort and the physiology of the human body and the climatic results …

    oxford-brookes Repository record for The windcatchers of Yazd (opens in a new tab)

  9. Modeling the Effects of Traffic Reduction on the Severity of the COVID-19 Epidemic in U.S. States

    … in limiting the overcrowding and shortage of ventilators, which can result in fewer deaths caused by COVID-19. This research provides insights for practitioners, researchers, and government entities developing and accessing plans for future pandemics. It is also expected that the findings of …

    embry-riddle Repository record for Modeling the Effects of Traffic Reduction on the Severity of the COVID-19 Epidemic in U.S. States (opens in a new tab)

  10. An Investigation into Using Ultrasound for Airway Humidification

    … relevant respiratory therapy equipment, such as ventilators.

    auckland-tech Repository record for An Investigation into Using Ultrasound for Airway Humidification (opens in a new tab)

  11. Kontorshotell Jonsereds fabriker - Fastighetsutveckling av gammal verkstadslokal

    … and a replacement and expansion of today’s smoke ventilators to roof lanterns. In order to achieve a flexible floor plan, two volumes are placed along the two long sides of the room. These volumes contain the offices and are divided with flexible, easy to move, inner walls. This allows the office …

    chalmers Repository record for Kontorshotell Jonsereds fabriker - Fastighetsutveckling av gammal verkstadslokal (opens in a new tab)

  12. The design and evaluation of the P₀.₁ method of assessing ventilatory drive

    Hypercapnia and/or hypoxia normally cause hyperventilation, The sensitivity to hypercapnia and hypoxia and the resultant hyperventilation is reduced in a patient suffering from damped respiratory centre activity. The P 0.1 method is a modification of the rebreathing technique where a patient …

    cape-town Repository record for The design and evaluation of the P₀.₁ method of assessing ventilatory drive (opens in a new tab)

  13. An examination of selected factors of public school construction in Indiana, 1966-1968

    … exterior walls, 38 or 35,84 per cent used unit ventilators for heating and cooling, 67 or 63.2 per cent had cooling to some extent, 58 or 54.71 per cent used natural gas for heat energy, 65 or 61.32 per cent used carpeting on less than 50 per cent of the floor surface, and 52 or 49.05 per cent …

    ballstate-thes Repository record for An examination of selected factors of public school construction in Indiana, 1966-1968 (opens in a new tab)

  14. Optimal design of sound absorbing systems with microperforated panels

    … in buildings, automotive systems or personal ventilators. In both applications, the focus was on obtaining the best possible performance in the full speech interference range, which spans the range from 500 Hz to 4000 kHz. In each case, a transfer matrix method has been developed to calculate …

    purdue-thes Repository record for Optimal design of sound absorbing systems with microperforated panels (opens in a new tab)

  15. Psychological Aspects of Ventilator Dependent Children

    <p>Rapid advances in medicine and technology have meant more medically invasive procedures as well as the survival of more individuals who are more immanently faced with death. Ventilator-dependent children (due to sleep apnea, neuromuscular disease, and acute physical injury) make up one such …

    loma-linda Repository record for Psychological Aspects of Ventilator Dependent Children (opens in a new tab)