Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 178 for “"Stent"”.

  1. Finite element tool for modelling stent deployment to aid stent design

    Includes bibliographical references (leaves 141-143).

    cape-town Repository record for Finite element tool for modelling stent deployment to aid stent design (opens in a new tab)

  2. Dynamics of endovascular stent expansion

    Thesis (Ph.D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2000.

    mit Repository record for Dynamics of endovascular stent expansion (opens in a new tab)

  3. Retrieving a Stent Navigating Deep Complications

    … proximal right coronary artery. Angioplasty and stenting were performed without complications. A second stent was advanced to treat a distal lesion. During the advancement, stent dislodgement from the guidewire, with entrapment in the struts of the previously placed stent and migration to the …

    rosario Repository record for Retrieving a Stent Navigating Deep Complications (opens in a new tab)

  4. Bioactive surfaces for improved coronary stent performance

    Drug eluting stents (DES) are widely used to treat coronary heart disease. Although current DES generally perform well, restenosis and delayed endothelium healing still remains an issue following stent implantations. Research efforts are now focused on the development of stent coatings that address …

    strathclyde Repository record for Bioactive surfaces for improved coronary stent performance (opens in a new tab)

  5. Computational analysis on stent geometries in carotid artery

    Stent implantation is an altemative invasive technique for treating the narrowed artery or stenosis in carotid artery to restore blood to the brain. However, the restenosis process is usually observed after a few weeks of carotid stenting due to abnormal progression of atherosclerosis and …

    uthm Repository record for Computational analysis on stent geometries in carotid artery (opens in a new tab)

  6. Experimentelle Untersuchungen am porzinen „over-sized coronary stent“-

    … at the porcine over-sized coronary stent-model for in-stent-restenosis rate after implantation of uncoated niob-zirkonium stents and niob-zirkonium stents coated with iridiumoxide. Background: The treatment of atherosclerotic stenosis in coronary artery disease with balloon …

    lmu-germany Repository record for Experimentelle Untersuchungen am porzinen „over-sized coronary stent“- (opens in a new tab)

  7. Quantifying AAAs and developing FEA models for stent grafts

    … (EVAR) is preferred, via the introduction of a stent graft into the aneurysmal region. In this thesis, finite element analysis (FEA) techniques have been developed to model the AnacondaTM stent graft. The aim is to produce the necessary numerical tools to allow for personalized EVAR simulations …

    strathclyde Repository record for Quantifying AAAs and developing FEA models for stent grafts (opens in a new tab)

  8. Arterial Calcification and the Clinical Implications on Stent Function

    … peripheral arterial disease (PAD), endovascular stenting can be a promising therapy that alleviates plaque obstruction and restores blood flow. However, stent fracture is a serious problem and it can lead to vascular complications, including restenosis. Stent fracture can be affected by type of …

    ohiolink Repository record for Arterial Calcification and the Clinical Implications on Stent Function (opens in a new tab)

  9. An investigation into stent expansion using numerical and experimental techniques

    … in the mechanical loading induced in vessels stented with various different stent designs and the influence of this loading on restenosis outcome. This study investigates the experimental validation of these numerical stent expansions using compliant mock arteries. The development of this …

    dcu Repository record for An investigation into stent expansion using numerical and experimental techniques (opens in a new tab)

  10. Production of Polyhydroxyalkanoates and their application for coronary stent development

    Development of coronary artery stents have revolutionised the treatment of coronary artery disease. However, the currently available stents have several limitations and side effects, which still need to be addressed. Within this group of biomaterials Polyhydroxyalkanoates (PHAs), which are …

    westminster Repository record for Production of Polyhydroxyalkanoates and their application for coronary stent development (opens in a new tab)

  11. Long-term patency of nitinol stent placement in dysfunctional hemodialysis

    Purpose: To evaluate the long-term patency of stents placement on dysfunctional hemodialysis shunt after failed balloon angioplasty and analysis the factors affecting the patency of nitinol stent. Materials and methods: Eighty-three patients with dysfunctional dialysis shunts underwent bail-out …

    ajou Repository record for Long-term patency of nitinol stent placement in dysfunctional hemodialysis (opens in a new tab)

  12. Stent Reliability and Maintenance: Integrating Probabilistic and Physics-of-Failure Models

    … study of such new devices. More than one million stents are implanted in human arteries each year. These devices are subject to a wide range of stress due to biological and procedural factors. Fatigue and structural damage can occur to stents that may lead to tumor formation, allergies or even …

    houston Repository record for Stent Reliability and Maintenance: Integrating Probabilistic and Physics-of-Failure Models (opens in a new tab)

  13. Innovation in medical devices : a case study of the coronary stent

    … a case study of introduction of the coronary stent into the percutaneous transluminal coronary angioplasty (PTCA) industry. The industry evolution is analyzed within the industrial life cycle framework developed by Utterback, Tushman and others. The coronary stent was first introduced in 1994, …

    mit Repository record for Innovation in medical devices : a case study of the coronary stent (opens in a new tab)

  14. Μηχανισμοί του μη θανατηφόρου οξέος εμφράγματος του μυοκαρδίου όψιμα μετά από εμφύτευση stent : ο ρόλος της επαναστένωσης, της θρόμβωσης του stent και της προόδου της στεφανιαίας νόσου

    … ή της θρόμβωσης της στεφανιαίας ενδοπροθέσεως (stent), καθώς και της προόδου της στεφανιαίας νόσου σε άλλο σημείο του αγγειακού δικτύου, ως υπεύθυνων μηχανισμών του οξέος εμφράγματος του μυοκαρδίου (ΟΕΜ) μετά την τοποθέτηση stent, δεν είναι αποσαφηνισμένη Μέθοδοι: Μετά από ανασκόπηση της βάσης …

    patras-thes Repository record for Μηχανισμοί του μη θανατηφόρου οξέος εμφράγματος του μυοκαρδίου όψιμα μετά από εμφύτευση stent : ο ρόλος της επαναστένωσης, της θρόμβωσης του stent και της προόδου της στεφανιαίας νόσου (opens in a new tab)

  15. Aplicación de la tomografía de coherencia óptica en la trombosis del stent

    … de la enfermedad coronaria con el implante de stents farmacoactivos de última generación es un procedimiento seguro y eficaz. La complicación más grave de este procedimiento es la trombosis del stent (TS), que, si bien tiene una baja incidencia con los stent utilizados en la actualidad, …

    oviedo Repository record for Aplicación de la tomografía de coherencia óptica en la trombosis del stent (opens in a new tab)

  16. Promoting endothelialisation to reduce vascular injury following coronary angioplasty and stent implantation

    … outcomes in patients undergoing angioplasty and stenting for coronary artery disease. I sought to establish a new cellular model to study the coronary endothelium in patients with acute myocardial infarction, and to utilise this model to identify novel polymer substrates that promote …

    edinburgh Repository record for Promoting endothelialisation to reduce vascular injury following coronary angioplasty and stent implantation (opens in a new tab)

  17. Finite Element Analysis of a Novel Design for a Non-Migrating Biliary Stent

    Biliary stenting is most frequently caused by an interruption in the ability to drain bile into the duodenum. This obstructive jaundice is commonly a result of a stricture from a tumor located at the pancreas’s head, peri-ampulary area, bile duct, or gall bladder. Jaundice can also occur from …

    wfu Repository record for Finite Element Analysis of a Novel Design for a Non-Migrating Biliary Stent (opens in a new tab)

  18. Clinical Aspects on Chimney Stent Graft Technique in Endovascular Repair of the Aorta.

    … proximal and distal sealing zone for the aortic stent graft. Fenestrated and branched stent grafts have made the repair possible for complex but elective cases that do not have an adequate sealing zone. Urgent complex cases and patients with midaortic occlusive diseases do not have any …

    lund Repository record for Clinical Aspects on Chimney Stent Graft Technique in Endovascular Repair of the Aorta. (opens in a new tab)

Page 1 of 9