Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 33 for “"Shear Connectors"”.

  1. Behaviour of demountable shear connectors in composite structures

    … is to evaluate the feasibility of demountable shear connectors as an alternative to welded shear connectors in composite structures through push off tests and composite beam tests. Push off tests were conducted to examine the shear strength, stiffness and ductility of demountable shear

    bradford Repository record for Behaviour of demountable shear connectors in composite structures (opens in a new tab)

  2. Horizontal Shear Connectors for Precast Prestressed Bridge Decks

    … as for new bridge construction. The horizontal shear strength at the interface between the two interconnected elements is of primary importance in order to provide composite action. The strength of the bond between the two precast members should be high enough to prevent any progressive slip …

    vt Repository record for Horizontal Shear Connectors for Precast Prestressed Bridge Decks (opens in a new tab)

  3. Behavior and Strength of Welded Stud Shear Connectors

    The behavior and strength of welded shear studs are subjects of ongoing study. In recent years, research has shown that the American Institute of Steel Construction (AISC) specification equations for shear stud strength are unconservative for studs placed in deck with ribs transverse to the steel …

    vt Repository record for Behavior and Strength of Welded Stud Shear Connectors (opens in a new tab)

  4. Standoff screws functioning as mechanical shear connectors in composite joists

    … standoff screw functioning as a mechanical shear connector are presented. In all tests, the base material, through which the screw was fastened, was fabricated out of back to back angle to simulate the top chord of an open web steel joist. Varied test parameters include: steel deck profile, …

    vt Repository record for Standoff screws functioning as mechanical shear connectors in composite joists (opens in a new tab)

  5. Evaluation of deck fasteners functioning as shear connectors for composite steel joists

    The use of deck fasteners as shear connectors for composite open web steel joists is studied. Results of thirty-six push-off tests are evaluated in terms of strength and behavior. Six types of deck fasteners are considered. They are: 1. #12-24 Teks/5 self-drilling, self-tapping screws. 2. 1/4-14 …

    vt Repository record for Evaluation of deck fasteners functioning as shear connectors for composite steel joists (opens in a new tab)

  6. HEADED STUD SHEAR CONNECTORS IN FULL-SIZE COMPOSITE BEAMS WITH WIDE RIBBED METAL DECK

    … investigation of the behavior of headed stud shear connectors embedded in slabs with wide ribbed metal deck oriented parallel to the beam. The test program involved the testing of 60 push-out specimens and 4 full-size beam specimens. The main objectives of this investigation were to evaluate …

    sask Repository record for HEADED STUD SHEAR CONNECTORS IN FULL-SIZE COMPOSITE BEAMS WITH WIDE RIBBED METAL DECK (opens in a new tab)

  7. Fatigue Performance and Shear Demand Distributions of Clustered Shear Connectors in Composite Bridge Girders

    … (AASHTO) Bridge Specifications assumes uniform shear flow demands at the steel-concrete interface of composite bridge girders. As stud pitch increases to beyond 24 in or as studs become clustered to account for pre-cast concrete decks, this assumed shear demand distribution may be …

    arkansas Repository record for Fatigue Performance and Shear Demand Distributions of Clustered Shear Connectors in Composite Bridge Girders (opens in a new tab)

  8. Design and Behavior of Composite Steel-Concrete Flexural Members with a Focus on Shear Connectors

    … members. The first part deals with a new type of shear connection in composite joists. Composite steel-concrete flexural members have increasingly become popular in design and construction of floor systems, structural frames, and bridges. A particularly popular system features composite trusses …

    vt Repository record for Design and Behavior of Composite Steel-Concrete Flexural Members with a Focus on Shear Connectors (opens in a new tab)

  9. Vibration based performance assessment of concrete-concrete composite bridges

    … cast in-situ slab are commonly connected using shear connectors. Failure of these connectors would compromise the composite action of the structure, thus reducing the load carrying capacity and hence its efficiency. This study seeks to assess the integrity of such shear connectors using dynamic …

    cape-town Repository record for Vibration based performance assessment of concrete-concrete composite bridges (opens in a new tab)

  10. Dynamic performance of pre-cast prestressed beams – cast in-situ slab composite bridges

    … in inaccessible parts of the structure such as shear connectors in concrete composite bridges remain undetected until catastrophic failure occurs. Localized non-destructive techniques such as ultrasonic techniques, radar method, impact testing, magnetic based methods and proof load tests are …

    cape-town Repository record for Dynamic performance of pre-cast prestressed beams – cast in-situ slab composite bridges (opens in a new tab)

  11. Construction and Behavior of Precast Bridge Deck Panel Systems

    … of transverse joints, different types of shear connectors, and different shear pocket spacings. The bridge consisted of two AASHTO type II girders, 40 ft long and simply supported, and five precast bridge deck panels. Two of the transverse joints were epoxied male-female joints and the …

    vt Repository record for Construction and Behavior of Precast Bridge Deck Panel Systems (opens in a new tab)

  12. Comportamento de placas compostas

    … concrete slabs with steel deck provide with shear connectors formed by steel bars welded on their rib tops. Besides the results of the tests of this work, summaries of other tests, of methods of calculation and of recommendations of codes related to the studied subject are here presented. A …

    brazil-uerj Repository record for Comportamento de placas compostas (opens in a new tab)

  13. Finite element modelling of shear connection for steel-concrete composite girders

    … models to trace the behaviour of headed stud shear connectors in composite girders with solid slabs and precast hollow core slabs. The finite element package ABAQUS was used to conduct the analysis. Push-off tests with both types of slabs were simulated taking into consideration all material …

    whiterose Repository record for Finite element modelling of shear connection for steel-concrete composite girders (opens in a new tab)

  14. Structural behaviour of precast lightweight foamed concrete sandwich panel (PLFP) with shear truss connectors

    … Foamed Concrete Sandwich Panel (PLFP) with shear truss connectors. The objectives of this study are to numerically investigate the PLFP panel with single and double shear truss connectors to determine its structural behaviour with validation from experimental work and to develop the …

    uthm Repository record for Structural behaviour of precast lightweight foamed concrete sandwich panel (PLFP) with shear truss connectors (opens in a new tab)

  15. Strength and Performance of Fiber-Reinforced Concrete Composite Slabs

    … under uniform load, the strength of two types of shear connectors used with composite beams and joists, composite slab strength due to a concentrated load, and the flexural toughness and first-crack strength of fiber-reinforced concrete using ASTM C1018 (1998) standard test. The performance of the …

    vt Repository record for Strength and Performance of Fiber-Reinforced Concrete Composite Slabs (opens in a new tab)

  16. Structural and Steady-State Thermal Experimental Investigations of an Insulated Sandwich Panel

    … with Glass Fibre Reinforced Polymer (GFRP) shear connectors can be a solution to increasing energy efficiency in building envelopes, while also providing many architectural, structural, and economic benefits for building designs. This study consists of extensive experimental investigation of …

    queens Repository record for Structural and Steady-State Thermal Experimental Investigations of an Insulated Sandwich Panel (opens in a new tab)

  17. On the Fatigue of Headed Shear Studs in Steel-Concrete Composite Bridge Girders

    <p>Shear connectors are commonly used in steel bridges to join the concrete deck and steel superstructure, providing a mechanism for shear transfer across the steel-concrete interface. The most common shear connector is the headed shear stud. In the current AASHTO LRFD Bridge Specifications on …

    arkansas Repository record for On the Fatigue of Headed Shear Studs in Steel-Concrete Composite Bridge Girders (opens in a new tab)

  18. Fatigue and static behaviour of post-tensioned steel-concrete composite beams

    … samples (steel beams, concrete flanges, and shear connectors), which enhanced the overall fatigue performance of the strengthened samples. However, the strengthened samples experienced longitudinal fatigue cracks in the concrete flanges because of PT while such cracks were not observed in the …

    missouri Repository record for Fatigue and static behaviour of post-tensioned steel-concrete composite beams (opens in a new tab)

Page 1 of 2