Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"Ray Casting"”.

  1. Interactive freeform solid modeling with haptic interface

    … of the tool swept volume, and based on the ray-casting method to perform Boolean operations between the tool swept volume and the virtual stock in dexel data to simulate the sculpting process. A new method for surface reconstruction from dexel data is presented"--Abstract, page iii.

    must-thes Repository record for Interactive freeform solid modeling with haptic interface (opens in a new tab)

  2. Localizing, modeling, and drifting an autonomous RACECAR

    … algorithm for high performance two-dimensional ray casting in occupancy grid maps, called the Compressed Directional Distance Transform (CDDT). Here, I will discuss the theory and characteristics of the CDDT algorithm, which has been implemented in RangeLibc, my open-source software library.

    mit Repository record for Localizing, modeling, and drifting an autonomous RACECAR (opens in a new tab)

  3. Rigid registration of MR and biplanar fluoroscopy

    … processing time relative even to optimized ray-casting methods. The computational efficiency of voxel-projection makes it a useful tool for the investigation of similarity measures in this 3D-2D context. Its speed may also enable 3D-2D registration methods which rely on evaluation of a …

    mit Repository record for Rigid registration of MR and biplanar fluoroscopy (opens in a new tab)

  4. Automatic pre-treatment validation in radiotherapy by computer aided 3D-2D image alignment

    … of object contours from the orthogonal X-ray images, matching with the 3D contours automatically extracted from the planning CT data. The registration is based on the Z-bnffer projection algorithm and the iterative closest point (ICP) algorithm. The novelty of the method proposed by the …

    cent-lancashire Repository record for Automatic pre-treatment validation in radiotherapy by computer aided 3D-2D image alignment (opens in a new tab)

  5. Techniques for Stochastic Implicit Surface Modelling and Rendering

    … algorithms are proposed. First, an improved ray casting method is presented that guarantees correct intersections between view rays and the surface. Second, a new progressive refinement rendering algorithm is proposed that provides a dynamic rendering environment where the image quality …

    whiterose Repository record for Techniques for Stochastic Implicit Surface Modelling and Rendering (opens in a new tab)

  6. Optimisation of computed radiography chest imaging utilising a novel simulation technique derived from real patient computed tomography data sets

    … data sets is presented. The algorithm uses a ray casting DRR calculation method to project X-ray pencil beams through CT data and derive the photon energy absorbed in a virtual computed radiography (CR) phosphor. Radiation scatter and CR system noise are added post DRR calculation.Quantitative …

    hull Repository record for Optimisation of computed radiography chest imaging utilising a novel simulation technique derived from real patient computed tomography data sets (opens in a new tab)

  7. Three-dimensional cloud volume reconstruction from the Multi-angle Imaging SpectroRadiometer

    … cloud masks. For the reconstruction method, “ray casting” algorithms that fully account for the instrument's geometric properties are developed. The reconstruction results are presented for three hand-picked MISR cloud scenes. Strengths and limitations of the reconstruction method are …

    uiuc Repository record for Three-dimensional cloud volume reconstruction from the Multi-angle Imaging SpectroRadiometer (opens in a new tab)

  8. Visual-auditory visualisation of dynamic multi-scale heterogeneous objects.

    … benefits from a combination of GPU accelerated ray-casting, geometry, optical and auditory properties modelling. We discuss how the modern GPU techniques application in those areas allows introducing a unified approach to the visual-auditory analysis of dynamic multi-scale heterogeneous objects. …

    bournemouth Repository record for Visual-auditory visualisation of dynamic multi-scale heterogeneous objects. (opens in a new tab)

  9. Visualization and Analysis Tools for Neuronal Tissue

    … scenes to be described and revisited. Finally, ray-casting support allows numerous analytical features, including 3D distance and volume measurements, computation and presentation of statistics, and point-and-click retrieval and presentation of raw electron microscopy data. The extension of this …

    wvu Repository record for Visualization and Analysis Tools for Neuronal Tissue (opens in a new tab)

  10. Robotics and Virtual Reality for Optical Coherence Tomography-Guided Ophthalmic Surgery and Diagnostics

    … data organization techniques for high-frame rate ray casting at 180 fps. We conduct performance analyses of these techniques, develop an interactive VR-OCT viewer, and demonstrate guidance of mock surgical procedures exclusively by live OCT and video feedthrough from within immersive …

    duke Repository record for Robotics and Virtual Reality for Optical Coherence Tomography-Guided Ophthalmic Surgery and Diagnostics (opens in a new tab)

  11. Vizualizace objemových dat pomocí volume renderingu

    V teoretické části se práce obecně zaměřuje na problematiku zobrazování objemových dat, vzájemně srovnává a hodnotí jednotlivé přístupy a čtenáři tak poskytuje dobrou základní orientaci v tematice. Podrobně jsou pak analyzovány metody vizualizace objemových dat pomocí mapování textur a pomocí …

    brno-tech Repository record for Vizualizace objemových dat pomocí volume renderingu (opens in a new tab)