Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 144 for “"Radiofrequency"”.

  1. Chemical Problems in Radiofrequency Spectroscopy

    Made available in DSpace on 2015-05-12T17:02:28Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 0006967.PDF: 3303782 bytes, checksum: a98c8486313757b8976f38de252f4604 (MD5) Previous issue date: 1953

    uiuc Repository record for Chemical Problems in Radiofrequency Spectroscopy (opens in a new tab)

  2. Structural Applications of Radiofrequency Spectroscopy

    Made available in DSpace on 2014-12-05T19:36:18Z (GMT). No. of bitstreams: 1 0015222.pdf: 5390547 bytes, checksum: f2c198cf5a8ec9b28bbb76f35c6e59d3 (MD5) Previous issue date: 1955

    uiuc Repository record for Structural Applications of Radiofrequency Spectroscopy (opens in a new tab)

  3. Relaxation Phenomena in Radiofrequency Spectroscopy

    Made available in DSpace on 2014-12-05T19:36:36Z (GMT). No. of bitstreams: 1 0020891.pdf: 3583044 bytes, checksum: 597d1b52b584983f8f1d7c63fd696b28 (MD5) Previous issue date: 1957

    uiuc Repository record for Relaxation Phenomena in Radiofrequency Spectroscopy (opens in a new tab)

  4. Approximate Thermal Modeling of Radiofrequency Cardiac Ablation

    … thesis is to increase the efficacy and safety of radiofrequency catheter ablation (RFCA) of cardiac tissue. The purpose of RFCA is to carefully heat selected locations in the heart. The resulting thermal injury creates lesions which prevent the generation or propagation of arrhythmias. The ability …

    byu Repository record for Approximate Thermal Modeling of Radiofrequency Cardiac Ablation (opens in a new tab)

  5. Radiofrequency losses in an NMR surface coil

    Radiofrequency energy loss has been investigated for a resonant NMR surface coil between 20 MHz and 400 MHz. High-field NMR (> 64 MHz) is used increasingly for human imaging and spectroscopy to achieve improved SNR and spectral resolution. RF losses in coils designed using conventional …

    mit Repository record for Radiofrequency losses in an NMR surface coil (opens in a new tab)

  6. Biologic Influence of 900MHz Radiofrequency Identification in Rat

    Background and PURPOSE: The RFID (Radiofrequency Identification)system that operated under the ultra high frequency(UHF) band, is advanced important technology in a variety of fields. A RFID system appreciate the objects through wireless communication with tags by harvesting enerty from the …

    ajou Repository record for Biologic Influence of 900MHz Radiofrequency Identification in Rat (opens in a new tab)

  7. Radiofrequency heating of nanoclusters and nanoparticles for enzyme activation

    Radiofrequency (RF) fields heat magnetic nanoparticles. Applications include remote drug delivery and noninvasive cancer therapy. The underlying objective is to increase temperatures precisely where desired without heating the surroundings. Before our work, the replicable limit of this precision …

    colostate Repository record for Radiofrequency heating of nanoclusters and nanoparticles for enzyme activation (opens in a new tab)

  8. Design of multidimensional radiofrequency pulses in magnetic resonance imaging

    Multidimensional radiofrequency (RF) pulses have wide applications in magnetic resonance imaging and spectroscopy experiments. These applications include reduced field-of-view (FOV) imaging of region-of-interest (ROI), B1 inhomogeneity correction, and simultaneous spatial-spectral selective …

    uiuc Repository record for Design of multidimensional radiofrequency pulses in magnetic resonance imaging (opens in a new tab)

  9. Radiofrequency detector coil performance maps for parallel MRI applications

    … speed limits. In parallel MRI, arrays of radiofrequency (RF) detector coil arrays are used to perform some degree of spatial encoding which complements traditional encoding using magnetic field gradients. As the acceleration factor increases, coil design becomes critical to the overall …

    mit Repository record for Radiofrequency detector coil performance maps for parallel MRI applications (opens in a new tab)

  10. Advanced Characterization of Materials for Superconducting Radiofrequency Accelerator Cavities

    Particle accelerators are a leading tool for frontier science. Pushing that frontier further demands more machines with higher performance, and more of a very expensive technology: superconducting radio-frequency (SRF) acceleration. From a materials perspective this means reducing residual surface …

    vt Repository record for Advanced Characterization of Materials for Superconducting Radiofrequency Accelerator Cavities (opens in a new tab)

  11. Modeling of carbonization and stalling during radiofrequency ablation and electrosurgery

    Radiofrequency (RF) thermal therapies, including RF ablation and electrosurgery, function by delivering alternating currents in the 100 kHz-1 MHz range to biological tissues. These currents generate electric fields that drive ionic oscillations in intracellular and extracellular fluids, producing …

    uiuc Repository record for Modeling of carbonization and stalling during radiofrequency ablation and electrosurgery (opens in a new tab)

  12. A Study of Radiofrequency Cardiac Ablation Using Analytical and Numerical Techniques

    <p>Studies on radiofrequency (RF) ablation are often aimed at accurately predicting tissue temperature distributions by numerical solution of the bioheat equation. This thesis describes the development of an analytical solution to serve as a benchmark for subsequent numerical solutions. The …

    byu Repository record for A Study of Radiofrequency Cardiac Ablation Using Analytical and Numerical Techniques (opens in a new tab)

  13. Chemical reaction in a radiofrequency discharge : the oxidation of hydrogen chloride

    Thesis (Sc. D.)--Massachusetts Institute of Technology, Dept. of Chemical Engineering, 1967.

    mit Repository record for Chemical reaction in a radiofrequency discharge : the oxidation of hydrogen chloride (opens in a new tab)

  14. THE APPLICATION OF RADIOFREQUENCY WAVES IN THE MANAGEMENT OF ORAL MAXILLOFACIAL PAIN

    … non-invasive approaches, including the use of radiofrequency diathermy. Diathermy employs high-frequency electromagnetic waves to generate endogenous tissue heating, promoting muscle relaxation, reduction of infection, and improvement of blood circulation, with potential benefits for pain …

    milano Repository record for THE APPLICATION OF RADIOFREQUENCY WAVES IN THE MANAGEMENT OF ORAL MAXILLOFACIAL PAIN (opens in a new tab)

  15. Radiofrequency ablation versus cryoablation in the treatment of atrioventricular nodal reentrant tachycardia

    … and safety. Two modalities of ablation, radiofrequency (RF) and cryoablation are commonly utilized in clinical practice with high levels of success in treating AVNRT. To date, studies on the two modalities have compared metrics such as acute success rate, procedure time, fluoroscopy time, …

    bu Repository record for Radiofrequency ablation versus cryoablation in the treatment of atrioventricular nodal reentrant tachycardia (opens in a new tab)

  16. Radiofrequency Spectroscopy: Electron Coupling of Four Nuclei With Spin of One-Half

    Made available in DSpace on 2014-12-05T19:37:16Z (GMT). No. of bitstreams: 1 6000190.pdf: 6495142 bytes, checksum: 19a2c29eaec86bfde742fba3fea98f04 (MD5) Previous issue date: 1959

    uiuc Repository record for Radiofrequency Spectroscopy: Electron Coupling of Four Nuclei With Spin of One-Half (opens in a new tab)

  17. Parallel radiofrequency transmission for 3 Tesla and 7 Tesla magnetic resonance imaging

    … Moreover, the tissue heating rate due to radiofrequency (RF) energy deposition (also called specific absorption rate or SAR) increases, limiting the imaging speed. Parallel RF transmission (pTx) was proposed to address both of these challenges by optimization of RF pulses transmitted from …

    mit Repository record for Parallel radiofrequency transmission for 3 Tesla and 7 Tesla magnetic resonance imaging (opens in a new tab)

Page 1 of 8