Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"RPPG"”.

  1. Evaluation of recrosslinkable preformed particle gel (RPPG) as a fluid loss control material during drilling operations

    … of a re-crosslinkable preformed particle gel (RPPG) has been conducted to determine the extent to which it can be used to control drilling fluid losses during drilling operations. The RPPG consists of swellable gel particles that can self-crosslink to form a strong bulk gel in fractures to form …

    must-thes Repository record for Evaluation of recrosslinkable preformed particle gel (RPPG) as a fluid loss control material during drilling operations (opens in a new tab)

  2. Investigation of Recrosslinkable Preformed Particle Gels for Natural Gas Conformance Control

    <p>"Recross linkable Preformed Particle Gel (RPPG) is a novel type of preformed particle gel in which particles can bond together to form a strong bulk gel system after being placed in the target formation. In this research, I systematically evaluated the feasibility of using this product to …

    must-thes Repository record for Investigation of Recrosslinkable Preformed Particle Gels for Natural Gas Conformance Control (opens in a new tab)

  3. EVALUATION OF NOVEL PREFORMED PARTICLE GELS FOR CONFORMANCE CONTROL AND ACID STIMULATION THROUGH CORE FLOODING TESTS

    … and Re-crosslinkable Preformed Polymer Gel (RPPG). DPPG is designed to be a temporary plugging agent for acid stimulation and can self-degrade into a water-like fluid. RPPG is designed for reservoir sweep efficiency improvement and can re-crosslink to each other and form an immobile bulk gel …

    must-thes Repository record for EVALUATION OF NOVEL PREFORMED PARTICLE GELS FOR CONFORMANCE CONTROL AND ACID STIMULATION THROUGH CORE FLOODING TESTS (opens in a new tab)

  4. Cardiac Signals: Remote Measurement and Applications

    … We report beat-to-beat accuracy of remote PPG (rPPG) in comparison to conventional average heart rate. The beat-to-beat accuracy is required for applications related to heart rate variability (HRV) and affective computing. The algorithm has been tested on two datasets, one with static …

    vt Repository record for Cardiac Signals: Remote Measurement and Applications (opens in a new tab)

  5. Plugging performance of preformed particle gels in fractures and its influencing factors

    … a novel re-crosslinkable preformed particle gel (RPPG) was evaluated as an agent specifically designed for healing large fractures. The evaluation of oxidizing breakers for the re-crosslinked RPPG was provided. Among the tested breakers, NaOH-activated Na<sub>2</sub>S<sub>2</sub>O<sub>8</sub> was …

    must-thes Repository record for Plugging performance of preformed particle gels in fractures and its influencing factors (opens in a new tab)