A comparison of fixed tube current (FTC) and automatic tube current modulation (ATCM) CT methods for abdominal scanning : implications on radiation dose and image quality
… CT scans generally require higher exposure factors when compared to other anatomical regions. This drives a need for urgent optimisation of the radiation dose and image quality for abdominal CT examinations. The aim of this thesis is to evaluate Fixed Tube Current (FTC) and Automatic Tube …
-
Non-uniform emission studies of a magnetron injection gun
… of the effects on the velocity spread and pitch factor of azimuthal non-uniformity in the MIG gun, showing that the direct effect on the beam quality is very small; Design, fabrication, and testing in the gyrotron of a capacitive probe system divided into four quadrants to measure azimuthal …
-
Design of a wideband, 100 W, 140 GHz gyroklystron amplifier
… with a 15 kV, 150 mA electron beam having a beam pitch factor of 1.5, radius of 0.64 mm and calculated perpendicular momentum spread of 4%. Preliminary designs of the Magnetron Inject Gun (MIG), the input and output couplers, and the mode converter to transform the TE(0,2) operating mode to the …
-
A novel wideband 140 GHz gyrotron amplifier
… from a 37 kV, 2.7 A electron beam having a beam pitch factor of 0.6, radius of 1.9 mm and calculated perpendicular momentum spread of approximately 9%. The gyro-amplifier was nominally operated at a pulse length of 2 microseconds, but was tested to amplify pulses as short as 4 nanoseconds with no …
-
A 140 GHz gyro-amplifier using a confocal waveguide : theory and experimental results
… GHz from a 48 kV, 3 A electron beam with a beam pitch factor of 0.64 and a perpendicular velocity spread of 6%. The gyro-TWT produced 550 W at 140.0 GHz under the same operating conditions. During experimental testing, the pulse length used was 2 microseconds. The performance of the confocal …
-
Styles of Play in Elite Soccer: Identification and Definition of the Attacking and Defensive Styles of Play in the English Premier League and the 1st Spanish League
… five in defence were measured in the analysis. Factor analysis using principal component analysis was carried out using the nineteen variables to cluster each team’s style of play based on their factor scores.Six factors, representing the different styles of play, were extracted and in …
-
The numerical and experimental investigation of gyro-multiplier configurations
… of voltage, 80 kV, beam current of 0.7 A, and pitch factor of 1.4, generation of the TE1,2 and TE1,3 modes at a fundamental frequency of 342.5 GHz, and 4th harmonic, polarised in the TE4,6 mode at a frequency of 1.37 THz has been predicted, for a modest confining magnetic field of ~14.15 T. …
-
The numerical and experimental investigation of gyro-multiplier configurations
… of voltage, 80 kV, beam current of 0.7 A, and pitch factor of 1.4, generation of the TE1,2 and TE1,3 modes at a fundamental frequency of 342.5 GHz, and 4th harmonic, polarised in the TE4,6 mode at a frequency of 1.37 THz has been predicted, for a modest confining magnetic field of ~14.15 T. …