Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"Photoplethysmography ppg"”.

  1. Motion Artifact Reduction in Impedance Plethysmography Signal

    … artifact from the electrocardiogram (ECG) and photoplethysmography (PPG) signals in the past few years. However, no such study exists for the Impedance Plethysmography (IP) signal. The IP signal can be used to monitor respiration in mobile devices. However, it is very susceptible to motion …

    vcu Repository record for Motion Artifact Reduction in Impedance Plethysmography Signal (opens in a new tab)

  2. Detecting Human Memory Processes via Bio-Signals

    Bio signals, such as eye movement data, photoplethysmography (PPG), and electrodermal activity (EDA), can provide insight into various cognitive states. Previous work has shown that eye movements along with other bio-signals differ when viewing familiar versus unfamiliar faces. Signals such as …

    mit Repository record for Detecting Human Memory Processes via Bio-Signals (opens in a new tab)

  3. Motion artifact cancellation for wearable photoplethysmographic sensor

    Photoplethysmography (PPG) is a non-invasive and unobtrusive technique to measure heart rate from the surface of the skin, by exposing a section of the skin to an LED light and measuring the changes in reflected light due to the blood pulsing through under the skin. However, PPG signals are highly …

    mit Repository record for Motion artifact cancellation for wearable photoplethysmographic sensor (opens in a new tab)

  4. A wearable blood pressure sensor using oscillometric photoplethysmography and micro accelerometers

    … and validated. A solid, coin-sized cuff-less photoplethysmography (PPG) sensor worn over a palpable artery is utilized to measure arterial blood pressure. Measurements are obtained through a modified oscillometric technique which eliminates the need for a high pressure cuff and instead, takes …

    mit Repository record for A wearable blood pressure sensor using oscillometric photoplethysmography and micro accelerometers (opens in a new tab)

  5. Psychological Monitoring: Detecting Real-Time Emotional Changes

    … a single, wearable-compatible signal through photoplethysmography (PPG). The tested model utilizes inter-beat interval (IBI) and pulse wave or pulse volume amplitude (PVA), which are tracked using an extended Kalman filter (EKF) to extract frequencies (VLF-UHF) and standard heart rate …

    vt Repository record for Psychological Monitoring: Detecting Real-Time Emotional Changes (opens in a new tab)

  6. Development of a new device to measure finger's mean arterial pressure

    … This type of measurement is derived from the photoplethysmography (PPG) signal which conventionally used to estimate the oxygen saturation level. A series of tests based on 10 subjects have been conducted in order to validate the Finger M.A.P device. From statistical analysis using Pearson …

    uthm Repository record for Development of a new device to measure finger's mean arterial pressure (opens in a new tab)

  7. Soft Electronics and Sensors for Wearable Healthcare Applications

    … electronic components and dry electrodes for photoplethysmography (PPG) and electrocardiography (ECG) recordings. Based on the developed PEDOT:PSS solution with high conductivity, we fabricated a porous PDMS sponge coated with conductive PEDOT:PSS to make electrodes with reduced electrode-skin …

    wustl Repository record for Soft Electronics and Sensors for Wearable Healthcare Applications (opens in a new tab)

  8. Wireless Monitoring of Driver's Pulse Rate and Temperature Using Hand Gloves Approach

    … Here the pulse sensor uses a technique called Photoplethysmography (PPG) and temperature sensor used here is LM35. The pulse sensor mounted on the index finger of the gloves acquires the raw data from the human body and then sends to the microcontroller using conductive thread. The conductive …

    arkansas Repository record for Wireless Monitoring of Driver's Pulse Rate and Temperature Using Hand Gloves Approach (opens in a new tab)

  9. Photoplethysmography for non-invasive measurement of bone hemodynamic responses to changes in external pressure

    … long duration human spaceflight. Developments in photoplethysmography (PPG) hardware have made it a promising tool for non-invasive bone hemodynamic measurements. The aims of this thesis are to: 1) validate the use of PPG as a tool for non-invasive bone hemodynamic measurements, 2) characterize …

    mit Repository record for Photoplethysmography for non-invasive measurement of bone hemodynamic responses to changes in external pressure (opens in a new tab)

  10. A comparative analysis of instructional techniques toward long-term positive ergonomics transformation for the early career sonographer

    … the likelihood of such future WRMSD complaints. Photoplethysmography (PPG) recordings during challenging maneuvers demonstrated additional benefit toward the reduction of negative scan behaviors; while transformational learning demonstrated significant benefit in both reducing negative scan …

    utc Repository record for A comparative analysis of instructional techniques toward long-term positive ergonomics transformation for the early career sonographer (opens in a new tab)

  11. Reflectance photoplethysmography for non-invasive monitoring of tissue perfusion

    … techniques have been developed over the decades. Photoplethysmography (PPG) is an optical technique that measures blood volume variations in vascular tissue and it is well known for its utilisation in pulse oximetry for the estimation of arterial blood oxygen saturation (SpO2). In pulse oximetry, …

    city-london Repository record for Reflectance photoplethysmography for non-invasive monitoring of tissue perfusion (opens in a new tab)

  12. Intra-operative optical monitoring of bowel tissue viability based on photoplethysmography and laser doppler flowmetry

    … techniques, laser Doppler flowmetry (LDF) and Photoplethysmography (PPG), into one probe intended for assessment of perfusion in abdominal tissue during bowel resection intraoperatively. In PPG, changes in transmission of light through tissue due to pulsation of small arteries can be monitored …

    city-london Repository record for Intra-operative optical monitoring of bowel tissue viability based on photoplethysmography and laser doppler flowmetry (opens in a new tab)

  13. A Robust Algorithm for Identification of Motion Artifacts in Photoplethysmography Signals

    Photoplethysmography(PPG) is commonly used as a means of continuous health monitoring. Many clinically relevant parameters like heart rate (HR), blood oxygenaton level (SPO2) are derived from the sensor measurements using PPG. Presence of motion artifacts in the signal decreases the accuracy of …

    rice Repository record for A Robust Algorithm for Identification of Motion Artifacts in Photoplethysmography Signals (opens in a new tab)

  14. Investigations of photoplethysmography in the assessment of haemodynamics, vascular mechanics and haemorheology

    … hypothesis is to show for the first time that Photoplethysmography (PPG) has the potential to non‐invasively assess, in a qualifying and quantifying manner, the above parameters. Positives outcomes from such approach will establish the potential of the PPG as a preferential monitoring …

    city-london Repository record for Investigations of photoplethysmography in the assessment of haemodynamics, vascular mechanics and haemorheology (opens in a new tab)

  15. In vivo investigations of photoplethysmograms and arterial oxygen saturation from the auditory canal in conditions of compromised peripheral perfusion

    Pulse oximeters rely on the technique of photoplethysmography (PPG) to estimate arterial oxygen saturation (SpO2). In conditions of poor peripheral perfusion such as hypotension, hypothermia, and vasoconstriction, the PPG signals detected are often small and noisy, or in some cases unobtainable. …

    city-london Repository record for In vivo investigations of photoplethysmograms and arterial oxygen saturation from the auditory canal in conditions of compromised peripheral perfusion (opens in a new tab)

  16. Exploring the Potential of Earables for Personal-Scale Sensing

    … microphones (facing in-the-ear-canal); (iii) photoplethysmography sensors (PPG). Data collected by earables augmented with these sensors in and around the ear may enable several personal-scale sensing applications such as augmented/virtual reality, improved navigation, medical rehabilitation, …

    cambridge Repository record for Exploring the Potential of Earables for Personal-Scale Sensing (opens in a new tab)

  17. Investigating Maladaptive Habit Formation and Threat Influences in Obsessive-Compulsive Disorder

    … (sAA) and heart rate data collected by photoplethysmography (PPG). Those experiencing a state-stressor prior to the PIT procedure showed significantly increased arousal and stress levels. Correlational analyses were conducted between trait-stress and compulsivity and general and specific …

    cambridge Repository record for Investigating Maladaptive Habit Formation and Threat Influences in Obsessive-Compulsive Disorder (opens in a new tab)

  18. Precision Technologies and Data Analytics for Monitoring Ruminants

    … and precision of a low-cost wearable sensor photoplethysmography (PPG) sensor in monitoring heart-rate (HR) of sheep housed under high-temperature conditions. The results revealed poor accuracy and precision in detecting HR changes using the PPG sensor. Future studies should explore …

    vt Repository record for Precision Technologies and Data Analytics for Monitoring Ruminants (opens in a new tab)