Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 30 for “"Oxygenator"”.

  1. Membrane materials for a nonthrombogenic blood oxygenator,

    Thesis: M.S., Massachusetts Institute of Technology, Department of Chemical Engineering, 1972

    mit Repository record for Membrane materials for a nonthrombogenic blood oxygenator, (opens in a new tab)

  2. An analysis of gas exchange in a membrane oxygenator.

    Thesis: Ph. D., Massachusetts Institute of Technology, Department of Chemical Engineering, 1966

    mit Repository record for An analysis of gas exchange in a membrane oxygenator. (opens in a new tab)

  3. Integrated Microfluidic Culture Media Oxygenator for Organ-on-a-Chip Applications

    … fabrication, and testing of a microfluidic oxygenator chip, or "Oxychip", for providing control of oxygen concentration in MPS cell culture media. The oxygenation mechanism of the device features a serpentine fluidic channel that contacts a pneumatic pocket through a gas permeable membrane, …

    mit Repository record for Integrated Microfluidic Culture Media Oxygenator for Organ-on-a-Chip Applications (opens in a new tab)

  4. History and Technique of Operation of the Mark G.K. Gibbon Type Pump-Oxygenator

    The evolution of heart surgery has been difficult and has spread over centuries. Yet only within the past twenty years have congenital abnormalities of the great vessels been successfully treated surgically. Except for traumatic lesions of the heart, significant sustained progress in the treatment …

    creighton Repository record for History and Technique of Operation of the Mark G.K. Gibbon Type Pump-Oxygenator (opens in a new tab)

  5. A low volume oxygenator for open well Liver-on-a-Chip tissue culture

    … flow-through MPS platform with a low-volume oxygenator, at a total circulating volume of approximately 500 [mu]L. The oxygenator uses the interior corner of a hydrophilic spiral to constrain the circulating fluid and to create a thin fluid region, which decreases the diffusion depth relative …

    mit Repository record for A low volume oxygenator for open well Liver-on-a-Chip tissue culture (opens in a new tab)

  6. Analysis of a membrane type blood oxygenator and a ventricle type blood pump

    … in vitro analysis of the Arp Hembrane Type Blood Oxygenator and a ventricle type blood pump. The system is designed for newborns suffering from Respiratory Distress Syndrome (R.D.S.), especially the 15% who are unable to be helped by the Arp Infant Respirator. The analysis included oxygen transfer …

    vt Repository record for Analysis of a membrane type blood oxygenator and a ventricle type blood pump (opens in a new tab)

  7. Use of blood oxygenator membrane units in teaching mass balances, friction factor and mass transfer analysis

    … laboratory experiments with hollow fiber blood oxygenators allow integration of concepts into already full programs. This work describes three new educational experiments that have been developed to introduce students to concepts of mass balances, mass transfer and momentum transfer as applied …

    rowan Repository record for Use of blood oxygenator membrane units in teaching mass balances, friction factor and mass transfer analysis (opens in a new tab)

  8. A new blood pump and oxygenator system for support of infants with neonatal respiratory distress: preliminary in vitro and in vivo evaluation

    A clinical need exists for a blood oxygenator and pumping system for the support of neonates with respiratory deficiencies. Such systems now available for support of adults are not suitable for neonatal patients. In vitro evaluation of a new blood oxygenator and blood pumping system was performed. …

    vt Repository record for A new blood pump and oxygenator system for support of infants with neonatal respiratory distress: preliminary in vitro and in vivo evaluation (opens in a new tab)

  9. Carbon dioxide transfer in membrane oxygenators and associated membranes

    … dioxide production be eliminated by a membrane oxygenator operated in an extracorporeal blood circuit. In conjunction with peripheral cannulation, the oxygenator should be optimised for CO₂ removal at low blood flow rates of 1.5 ℓ/min or less for adults. An extensive literature survey revealed …

    strathclyde Repository record for Carbon dioxide transfer in membrane oxygenators and associated membranes (opens in a new tab)

  10. STUDIES ON THE REACTION OF HIGH-DOSE HYDROXOCOBALAMIN AND ASCORBIC ACID WITH CARBON MONOXIDE: IMPLICATIONS FOR TREATMENT OF CARBON MONOXIDE POISONING

    … circulation system with a hollow-fiber membrane oxygenator to produce carboxyhemoglobin. Using sensitive gas monitoring equipment to the gas-out port of the oxygenator we analyzed the CO and CO2 concentrations coming from the oxygenator. The mixture of hydroxocobalamin and ascorbic acid caused a …

    vcu Repository record for STUDIES ON THE REACTION OF HIGH-DOSE HYDROXOCOBALAMIN AND ASCORBIC ACID WITH CARBON MONOXIDE: IMPLICATIONS FOR TREATMENT OF CARBON MONOXIDE POISONING (opens in a new tab)

  11. A monitoring and display system for a cardiopulmonary bypass loop

    … of sample points entering and leaving the blood oxygenator, patient temperature, oxygenator heat exchanger water temperature and hemoglobin content are monitored and displayed. The hemoglobin content and oxygen saturation signals, input from a reflective-type hemoglobin meter and oximeter are …

    vt Repository record for A monitoring and display system for a cardiopulmonary bypass loop (opens in a new tab)

  12. The development of a continuous blood oxygen saturation measuring and control system

    … saturation at the outlet of a membrane-type oxygenator. A reflection oximeter was developed which employs the ratio of the incident light intensity at two wavelengths to obtain the continuous blood oxygen saturation measurement. The ratio of the intensities of incident light at the two …

    vt Repository record for The development of a continuous blood oxygen saturation measuring and control system (opens in a new tab)

  13. Zur Frage der Stofftransporteigenschaften von Oxygenatorhohlfasermembranen bezüglich der Durchlässigkeit für Fluide und Narkosegase

    Microporous hollow fibre membrane oxygenators with clinically-established polypropylene (PP) or innovative polymethylpentene (PMP) membranes are used clinically for cardiopulmonary bypasses (CPB) and extracorporeal life support (ECLS). Membrane oxygenators with silicone plates may also be used. …

    aachen Repository record for Zur Frage der Stofftransporteigenschaften von Oxygenatorhohlfasermembranen bezüglich der Durchlässigkeit für Fluide und Narkosegase (opens in a new tab)

  14. Zu Entstehungsmechanismen von Plasma Leakage in mikroporösen Kapillarmembranoxygenatoren

    … is a particular problem of microporous membrane oxygenators. It is described as the migration of blood plasma through the micropores into the gas compartment. In this dissertation, in-vitro-studies, wettability measurements, and electron microscope photos of microporous hollow fibres were used to …

    aachen Repository record for Zu Entstehungsmechanismen von Plasma Leakage in mikroporösen Kapillarmembranoxygenatoren (opens in a new tab)

  15. Tierexperimentelle Untersuchungen zu Praktikabilität und Hämokompatibilität einer miniaturisierten extrakorporalen Membranoxygenierung

    … membrane oxygenation using capillary membrane oxygenators specialized centers have the possibility to provide sufficient gas exchange in severe ARDS with life-threatening hypoxemia despite optimal conservative treatment. The standard device used for ECMO is accompanied by several problems, for …

    aachen Repository record for Tierexperimentelle Untersuchungen zu Praktikabilität und Hämokompatibilität einer miniaturisierten extrakorporalen Membranoxygenierung (opens in a new tab)

  16. Renal function during profound hypothermia in the dog

    … incorporated in an extra-corporeal pump-oxygenator system (ef Appendix A). Progress was such that by midyear postoperative survival of experimental animals was assured. At this juncture, it was suggested that, as a member of the Renal-Metabolic Group of the Department of Medicine, I …

    cape-town Repository record for Renal function during profound hypothermia in the dog (opens in a new tab)

  17. The investigation of a non-invasive oximeter and the further development of an extracorporeal oximeter

    … of blood entering and leaving a membrane-type oxygenator. The oximeter was redesigned to improve the transducer, power supply, analog-to-digital converter, and calibration procedure. A detailed description of the new oximeter design is presented along with data obtained from testing the new …

    vt Repository record for The investigation of a non-invasive oximeter and the further development of an extracorporeal oximeter (opens in a new tab)

  18. OVERCOMING THE LIMITATIONS OF TISSUE ENGINEERED SCAFFOLDS FOR DENTAL ROOT REPAIR

    … system via burn out of porous polypropylene oxygenator membranes allows for proper nutrient delivery to the infiltrating cells. Blackened carbon-coated scaffolds acted as a filter for the media, resulting in no nutrient delivery to the cells. The new white scaffolds did not filter the media …

    buffalo Repository record for OVERCOMING THE LIMITATIONS OF TISSUE ENGINEERED SCAFFOLDS FOR DENTAL ROOT REPAIR (opens in a new tab)

Page 1 of 2