  1. Proniosome formulations for pulmonary drug delivery

    … Omron Micro Air NEU22 (passively vibrating-mesh) nebulisers. The Pari and Aeroneb Pro nebulisers generated higher aerosol and drug outputs compared with the Omron nebuliser. Whilst drug output was around 80% for the Pari and the Aeroneb Pro, it was around 70% for the Omron. Similarly, droplet size …

    cent-lancashire Repository record for Proniosome formulations for pulmonary drug delivery (opens in a new tab)

  2. ANTIMONY SPECIATION BY CHROMATOGRAPHIC SAMPLE INTRODUCTION TO PLASMA SPECTROSCOPY

    … first time. A fundamental investigation of the nebuliser/spray chamber assembly was carried out in terms of the effect on the quality of the chromatographic separations. It was found that the resolution was strongly dependent upon choice of nebuliser and spraychamber. Five nebulisers and two …

    plymouth Repository record for ANTIMONY SPECIATION BY CHROMATOGRAPHIC SAMPLE INTRODUCTION TO PLASMA SPECTROSCOPY (opens in a new tab)

  3. Elemental speciation and miniaturised sample introduction studies for inductively coupled plasma mass spectrometry

    … spray chambers. A low flow micro-concentric nebuliser (MicroMist) is used to generate the sample aerosol. No sample recondensation is ever observed in the evaporation chamber at flow rates up to 20 micro-l/min. A comparison with a commercial low volume cyclonic spray chamber (Cinnabar) is …

    hull Repository record for Elemental speciation and miniaturised sample introduction studies for inductively coupled plasma mass spectrometry (opens in a new tab)

  4. Relative bioavailability of terbutaline to the lungs following inhalation using different methods.

    … Aeroneb Pro (vibrating mesh) and Sidestream jet nebulisers were determined by the CEN methodology and the Next Generation Impactor (NGI) methodology. The Aeroneb Pro was found to have significantly better aerodynamic properties than the Sidestream. The results from the NGI method were …

    bradford Repository record for Relative bioavailability of terbutaline to the lungs following inhalation using different methods. (opens in a new tab)

  5. Proliposome Technology for Protein Delivery

    … for respiratory tract delivery via medical nebulisers and nasal sprays with different operating principles. Liposomes generated from the proliposome technology were multilamellar as cryo-TEM studies revealed. The generated liposomes were capable of entrapping considerable concentrations of …

    cent-lancashire Repository record for Proliposome Technology for Protein Delivery (opens in a new tab)

  6. INVESTIGATION OF CHEMOMETRICS METHODS FOR CHARACTERISING DRIFT PHENOMENA IN iCK-AES

    … (i.e. robust conditions, high RF power and low nebuliserflow rate). At soft conditions, low RF power and medium to high nebuliser flow rate, the system Is very unstable and intemal standardisation is not fully effective as a correction method. For such conditions, a novel correction procedure …

    plymouth Repository record for INVESTIGATION OF CHEMOMETRICS METHODS FOR CHARACTERISING DRIFT PHENOMENA IN iCK-AES (opens in a new tab)

  7. THE INTERFERENCE FREE DETERMINATION OF SELENIUM IN ENVIRONMENTAL AND CLINICAL SAMPLES BY ICP-MS

    … of both nitrogen and helium to the argon nebuliser and outer gas streams, resulted in a reduction in the interference from argon polyatomic species. Careful optimisation of plasma parameters such as RF power and gas flow rates using a plasma containing 50% helium in the argon outer gas …

    plymouth Repository record for THE INTERFERENCE FREE DETERMINATION OF SELENIUM IN ENVIRONMENTAL AND CLINICAL SAMPLES BY ICP-MS (opens in a new tab)

  8. Proliposome and Prosurfactosome Formulations for Pulmonary Drug Delivery

    … was studied using PARI LC sprint air jet nebuliser, Aeroneb pro and Beurer iH50 vibrating mesh nebulisers. Two stage (Twin) impinger was used to study the potential suitability of the generated vesicles for inhalation. VMD, span and zeta potential of vesicles before and after nebulisation …

    cent-lancashire Repository record for Proliposome and Prosurfactosome Formulations for Pulmonary Drug Delivery (opens in a new tab)

  9. FLUORESCENCE STUDIES IN THE INDUCTIVELY COUPLED PLASMA

    … i.e. forward power; viewing height ALC; plasma, nebuliser and auxiliary gas flow rates. Once the optimum conditions had been determined, calibration curves were plotted for each of the elements studied (Ba, Li, Mg and Na). The calibration showed excellent linearity over five orders of magnitude …

    plymouth Repository record for FLUORESCENCE STUDIES IN THE INDUCTIVELY COUPLED PLASMA (opens in a new tab)