Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"Microtubes."”.

  1. Polymer, Metal, and Ceramic Microtubes by Strain-driven Self-rolling

    … is removed by pyrolysis resulting in pure metal microtubes. The fabrication of silica and silica/gold hybrid tubes of high aspect ratio is also demonstrated. Polydimethylsiloxane (PDMS) is used as a precursor of the silica and it is converted into silica by pyrolysis at high temperature. Entire …

    qucosa-diss

  2. Experimental Investigation of Liquid and Particle -Laden Flows in Microtubes

    Since flow blockages are the ultimate form of increased flow resistance, the research emphasis is focused on the mechanisms that lead to blockage. Different blockage mechanisms are observed in different regimes defined by the ratio of particle diameter to tube diameter. For example, for 0.33 D < dp …

    uiuc Repository record for Experimental Investigation of Liquid and Particle -Laden Flows in Microtubes (opens in a new tab)

  3. NUMERICAL ANALYSIS OF CO-FLOWING IMMISCIBLE LIQUIDS IN CO-AXIAL MICROTUBES

    This research developed dimensionless correlations, based on the numerical simulations, for the boundaries between the dripping, transition and jetting regimes. Additional correlations are also developed for the radius and formation frequency of disperse droplet in the dripping regime and the …

    unm Repository record for NUMERICAL ANALYSIS OF CO-FLOWING IMMISCIBLE LIQUIDS IN CO-AXIAL MICROTUBES (opens in a new tab)

  4. An experimental investigation of heat transfer to hydrogen peroxide in microtubes

    … 4 mm long, electrically heated stainless steel microtubes have been performed to define the stability limit and explosion condition associated with 98% hydrogen peroxide thermal decomposition. Conditions such as pressures, temperatures, heat fluxes and length scale found in the engine were …

    mit Repository record for An experimental investigation of heat transfer to hydrogen peroxide in microtubes (opens in a new tab)

  5. Self-rolled-up microtubes for on-chip microfluidic DNA storage and passive electronics applications

    Submission published under a 24 month embargo labeled 'Closed Access', the embargo will last until 2025-08-01

    uiuc Repository record for Self-rolled-up microtubes for on-chip microfluidic DNA storage and passive electronics applications (opens in a new tab)

  6. Modelling and multi-objective optimisation of heat transfer characteristics and pressure drop of nanofluids in microtubes

    A literature study was performed on the inner mechanisms of nanofluids and flow in microchannels. With ever changing technology, the need for smaller and more efficient devices has come about in the last couple of years. With the shrinking in size of components in electronics, an increase in heat …

    pretoria Repository record for Modelling and multi-objective optimisation of heat transfer characteristics and pressure drop of nanofluids in microtubes (opens in a new tab)

  7. Characterization of neurite growth on a novel neurotube platform

    … optically transparent, self-rolling microtubes are presented and the interaction of the neurites with the microtubes is analyzed. This novel substrate and application have the potential to provide unique insights into the mechanisms that drive organization of the dendritic …

    uiuc Repository record for Characterization of neurite growth on a novel neurotube platform (opens in a new tab)

  8. Determination of the Leak Size Critical to Package Sterility Maintenance

    … pressures (Po) required to initiate flow through microtubes of IDs 0, 2, 5, 7, 10, 20 or 50 m, were measured using 63 test cells filled with safranin red dye, tryptic soy broth, and distilled water with surface tensions of 18.69 mN/m, 44.09 mN/m, and 64.67 mN/m, respectively. Significant …

    vt Repository record for Determination of the Leak Size Critical to Package Sterility Maintenance (opens in a new tab)

  9. Competitive Enzyme Immunoassay by Polyclonal Antibodies Against Organophosphorus Pesticides

    … required to test OPs.</p> <p>Microwells and microtubes were utilized as the solid-phase immobilization for the development of an enzyme immunoassay for OPs. A sensitive and simple microtube based competition enzyme immunoassay for the quantitative determination of organophosphorus compounds …

    odu Repository record for Competitive Enzyme Immunoassay by Polyclonal Antibodies Against Organophosphorus Pesticides (opens in a new tab)

  10. Aerosol exposure biotesting for package integrity testing

    … contamination of sealed flexible pouches. Nickel microtubes with 10 μm and 20μm hole diameters and lengths of 5 mm and 10 mm were used in various combinations to create seal defects in 128 retortable pouches. A 119,911 cm³, exposure chamber was used to distribute an aerosol with a particle size of …

    vt Repository record for Aerosol exposure biotesting for package integrity testing (opens in a new tab)

  11. Predicting Package Defects: Quantification of Critical Leak Size

    … chamber was used to test micro-defects, nickel microtubes of known diameters 2, 5, 7, 10, 20, and 50 μm hydraulic diameters, against pressure differentials of 0, -6.9, -13.8, and -34.5 kPa.

    vt Repository record for Predicting Package Defects: Quantification of Critical Leak Size (opens in a new tab)

  12. Application of self-rolled-up membrane technology for enhanced neuron guidance and alignment

    … foundation for further adaptation of the SiNx microtubes for applications for neuroregenerative therapies.

    uiuc Repository record for Application of self-rolled-up membrane technology for enhanced neuron guidance and alignment (opens in a new tab)

  13. Biomedical applications of nanostructured polymer films

    … In addition, we have designed polymeric microtubes that can control their orientation on the surface of living cells. Inspired by chemically non-uniform Janus particles, we designed tube-shaped, chemically non-uniform microparticles with cell-adhesive ligands on the ends of the tubes and …

    mit Repository record for Biomedical applications of nanostructured polymer films (opens in a new tab)

  14. The Simulation, Development, and Testing of a Staged Catalytic Microtube Ignition System

    … safety. This study demonstrates that catalytic microtubes can be used to cause ignition of a bipropellant mixture in a rocket application and develops a unique ignition system as a low energy alternative or redundant ignition system as compared to current spark systems. Part I covers the …

    ohiolink Repository record for The Simulation, Development, and Testing of a Staged Catalytic Microtube Ignition System (opens in a new tab)

  15. Development of Novel Methodologies for the Electrodeposition of Polypyrrole-based Films in Controlled Morphologies with Potential Application in Nitrate Sensing.

    … TEM analysis of individual closed-pore microtubes identified a hollow interior at the base within which the toluene droplet was encapsulated. This cavity may be used to entrap other compounds making these materials useful in a range of applications. The methodology was also applied to …

    maynooth Repository record for Development of Novel Methodologies for the Electrodeposition of Polypyrrole-based Films in Controlled Morphologies with Potential Application in Nitrate Sensing. (opens in a new tab)

  16. Strain-induced self-rolled-up semiconductor micro/nanotubes: Fabrication and characterization

    … GaAs quantum well tubes. Optical properties of microtubes where the GaAs quantum well is embedded in the tube wall as the optical gain medium will be studied using the photoluminescence measurement system. Chapter 5 demonstrates several types of hybrid tubes. Metal/semiconductor, silicon …

    uiuc Repository record for Strain-induced self-rolled-up semiconductor micro/nanotubes: Fabrication and characterization (opens in a new tab)

  17. Facile protein and amino acid substitution reactions and their characterization using thermal, mechanical and optical techniques

    The work focused on addressing four main objectives. The first objective was to quantify protein and amino acid substitution reactions. Michael addition reactions were used to modify the amino acids and protein. Amino acids alanine, cysteine, and lysine, and protein ovalbumin (OA) were substituted …

    vt Repository record for Facile protein and amino acid substitution reactions and their characterization using thermal, mechanical and optical techniques (opens in a new tab)