Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"MULTISTORY BUILDINGS"”.

  1. Seismic Design and Evaluation of Multistory Buildings Using Yield Point Spectra

    … response and interstory drift indices of multistory buildings using YPS and establish SDOF formulations is also presented. The method may be considered a new nonlinear static procedure (NSP). Interstory drift indices (IDIs) are estimated using deformed shapes of the building based on the …

    uiuc Repository record for Seismic Design and Evaluation of Multistory Buildings Using Yield Point Spectra (opens in a new tab)

  2. Multi-objective optimization for structure and energy in the case of multistory buildings with atriums

    … with operational energy efficiency for buildings that incorporate natural ventilation practices. The parametric model successfully generates floor-framing plans with atriums that are similar to industry standards. Furthermore, this research follows a workflow that allows one to search …

    mit Repository record for Multi-objective optimization for structure and energy in the case of multistory buildings with atriums (opens in a new tab)

  3. Vibration of Buildings Under Random Wind Loads

    … two of the major environmental forces acting on multistory buildings. Since current design practice often leads to slender and flexible buildings, the dynamic effects of the wind are of increasing importance. The purpose of this study was to develop a method for analyzing the three-dimensional …

    uiuc Repository record for Vibration of Buildings Under Random Wind Loads (opens in a new tab)

  4. What Is The Economic Feasibility Of Implementing Grey Water Infrastructure At The Citywide Level?

    … large projects (such as apartment complexes and multistory buildings) are only economically feasible (as opposed to single-family homes), decentralized (on-site) systems also appear to be more economically feasible due to cost savings of energy and piping required to convey grey water and waste …

    usfca Repository record for What Is The Economic Feasibility Of Implementing Grey Water Infrastructure At The Citywide Level? (opens in a new tab)

  5. Multiplexing of Extrinsic Fabry-Perot Optical Fiber Sensors for Strain Measurements

    … are becoming obsolete in sensing for today's multistory buildings because they don't monitor the structural health of the guide rails. This sensing task falls into the fiber sensing niche market because of a fiber sensor's ability to be multiplexed. Previous work by Taplin and Jackson showed …

    vt Repository record for Multiplexing of Extrinsic Fabry-Perot Optical Fiber Sensors for Strain Measurements (opens in a new tab)

  6. Cálculo aproximado da deflexão lateral em edifícios altos

    … for a quick calculation of lateral deflection of multistory buildings. At preliminary stage of design, the use of approximate methods is very interesting, because use of computer programs with preliminary data is not a good practice. A method to do the compatibility of the lateral deflection at …

    brazil-uerj Repository record for Cálculo aproximado da deflexão lateral em edifícios altos (opens in a new tab)

  7. Análise, dimensionamento, detalhamento e desenho de estruturas de edifícios de concreto armado por microcomputadores

    … detailing and drawing of reinforced concrete multistory buildings by desk-computers are the main objectives of this work. A FORTRAN 77 language especific system based on the work of Menezes [25] was developed, where the floors are considered as grids supported on the columns and with elastic …

    brazil-uerj Repository record for Análise, dimensionamento, detalhamento e desenho de estruturas de edifícios de concreto armado por microcomputadores (opens in a new tab)

  8. Autoclaved Aerated Concrete Tile Vaults for Lightweight Floor Systems

    In the construction of multistory buildings, the reinforced concrete flat slab is a preferred floor system in part due to ease of formwork construction, which does not require skilled labor. However, the flat slab carries load primarily in bending, forcing much of the concrete section to crack …

    mit Repository record for Autoclaved Aerated Concrete Tile Vaults for Lightweight Floor Systems (opens in a new tab)

  9. ΔΙΕΡΕΥΝΗΣΗ ΤΗΣ ΑΞΙΟΠΙΣΤΙΑΣ ΙΣΟΔΥΝΑΜΩΝ ΠΛΑΙΣΙΑΚΩΝ ΠΡΟΣΟΜΟΙΩΜΑΤΩΝ ΓΙΑ ΠΥΡΗΝΕΣ ΠΟΛΥΟΡΟΦΩΝ ΚΤΙΡΙΩΝ ΥΠΟ ΟΡΙΖΟΝΤΙΑ ΦΟΡΤΙΣΗ

    IN AN EFFORT TO FIND ALL THE WEAK POINTS OF THE EQUIVALENT FRAME METHOD A DETAILED COMPARISON OF CHARACTERISTIC PARAMETERS SUCH AS DISPLACEMENTS, ROTATIONS, FORCES AND STRESSES WITH RESULTS OBTAINED USING MORE ACCURATE ANALYTICAL METHODS(SURFACE FINITE ELEMENTS AND CONTINUOUS MODEL OF VLASSOV) HAS …

    greece Repository record for ΔΙΕΡΕΥΝΗΣΗ ΤΗΣ ΑΞΙΟΠΙΣΤΙΑΣ ΙΣΟΔΥΝΑΜΩΝ ΠΛΑΙΣΙΑΚΩΝ ΠΡΟΣΟΜΟΙΩΜΑΤΩΝ ΓΙΑ ΠΥΡΗΝΕΣ ΠΟΛΥΟΡΟΦΩΝ ΚΤΙΡΙΩΝ ΥΠΟ ΟΡΙΖΟΝΤΙΑ ΦΟΡΤΙΣΗ (opens in a new tab)