Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"MR angiography"”.

  1. Magnetic resonance imaging modeling and applications to fast imaging and guidance of ultrasound surgery.

    Magnetic Resonance Imaging (MRI) is the only known radiological modality that provides a diagnostic cross sectional images non-invasively in virtually any orientation without patient repositioning. The principles of MRI are based on Bloch's equations, which describe the behavior of proton molecules …

    arizona-thes Repository record for Magnetic resonance imaging modeling and applications to fast imaging and guidance of ultrasound surgery. (opens in a new tab)

  2. EVALUATION OF INTERPOLATION AND REGISTRATION TECHNIQUES IN MAGNETIC RESONANCE IMAGE FOR ORTHOGONAL PLANE SUPER RESOLUTION RECONSTRUCTION

    … use this concept on magnetic resonance imaging (MRI) data, for which the standard is to scan in several-plane orientation in a 2D fashion. As a result, clinical MRI, functional MRI (FMRI), diffusion weighted imaging (DWI)/diffusion tensor imaging (DTI), and MR angiography (MRA) tend to have high …

    ohiolink Repository record for EVALUATION OF INTERPOLATION AND REGISTRATION TECHNIQUES IN MAGNETIC RESONANCE IMAGE FOR ORTHOGONAL PLANE SUPER RESOLUTION RECONSTRUCTION (opens in a new tab)

  3. Motion -Compensated 3-D Generalized Series Imaging

    Three-dimensional magnetic resonance (MR) imaging is highly desirable from the standpoints of minimum voxel size, volumetric coverage and signal-to-noise efficiency. Unfortunately, long scan times have traditionally precluded the use of 3-D imaging in applications where simultaneous resolution of …

    uiuc Repository record for Motion -Compensated 3-D Generalized Series Imaging (opens in a new tab)

  4. Flow velocity measurement in haemodialysis access using 4D MRI

    … the required imaging was provided by contrasted MRI, contraindicated in renal failure. Haemodynamic data was prvided by, amongst other things, duplex Doppler. New MRI software that provides imaging data as well as haemodynamic information without using contrast could be used to provide new …

    cape-town Repository record for Flow velocity measurement in haemodialysis access using 4D MRI (opens in a new tab)

  5. Diagnostik der Becken-Bein-Gefässe mittels kontrastmittelangehobener 3D-MR-Angiographie

    OBJECTIVE: To evaluate contrast-enhanced 3D-MR-Angiography for the assessment of peripheral arteries from the abdominal aorta to the lower leg arteries. METHODS: 3D-MRA was performed in 62 patients, using a Gd-DTPA enhanced T1 weighted 3D gradient-echo sequence (FFE). Results for 23 vascular …

    aachen Repository record for Diagnostik der Becken-Bein-Gefässe mittels kontrastmittelangehobener 3D-MR-Angiographie (opens in a new tab)

  6. Experimentelle Magnetresonanzangiographie unter Verwendung von kontrastangehobenen und flußrichtungssensitiven Meßtechniken

    … and further development of a new flow sensitive MR protocol in a pig model. 2.To prove the value of blood pool contrast agents in MR coronary angiography using an established ultrafast two dimensional gradient echo sequence. Material and methods: After verification and modification of the MR …

    aachen Repository record for Experimentelle Magnetresonanzangiographie unter Verwendung von kontrastangehobenen und flußrichtungssensitiven Meßtechniken (opens in a new tab)

  7. The study of blood flow in human arterial bifurcations by the combination of CFD and MRI

    … two new methodologies,namely magnetic resonance angiography (MRA) and computational fluid dynamics CFD), the precise patterns of flow anticipating the onset of disease at arterial bifurcations can now, in principle, be determined. However, flow simulations based on in vzvo data directly acquired …

    city-london Repository record for The study of blood flow in human arterial bifurcations by the combination of CFD and MRI (opens in a new tab)

  8. Interventionelle Behandlung intrakranieller Gefäßstenosen mittels ballongestützter Angioplastie und Implantation unbeschichteter und medikamentenbeschichteter Stentsysteme

    … preinterventional degree of stenoses was 83.25%. MRI was carried out before and after intervention including diffusion weighting and a neurological examination. The findings of the neurological examination were retrospectively transferred to a standardised assessment during evaluation with the …

    aachen Repository record for Interventionelle Behandlung intrakranieller Gefäßstenosen mittels ballongestützter Angioplastie und Implantation unbeschichteter und medikamentenbeschichteter Stentsysteme (opens in a new tab)

  9. Intracranial Vascular Findings in a Tri-Ethnic Population – MR Phenotypes and Physiological Parameters

    … concerning non-ionising magnetic resonance (MR) imaging techniques, brain imaging has become a firmly established tool for this purpose in both the clinical and research settings. However, current knowledge of the cerebral circulation still remains limited. Clear evidence of the anatomical …

    cambridge Repository record for Intracranial Vascular Findings in a Tri-Ethnic Population – MR Phenotypes and Physiological Parameters (opens in a new tab)

  10. Three-dimensional Quantitative Magnetic Resonance Imaging of Carotid Atherosclerotic Plaque

    … multi-contrast magnetic resonance imaging (MRI) can qualitatively identify these features and monitor disease progression. Compared to traditional contrast weighted imaging, quantitative MRI could provide an objective assessment of disease. Therefore, the general hypothesis investigated in …

    cambridge Repository record for Three-dimensional Quantitative Magnetic Resonance Imaging of Carotid Atherosclerotic Plaque (opens in a new tab)

  11. Akustisches Synchronisationsverfahren für die Magnetresonanztomographie

    In current clinical MR practice, cardiac motion is dealt with using electrocardiographic (ECG) gating to synchronize data acquisition with the cardiac cycle. ECG, being an inherently electrical measurement, is corrupted by interferences with electromagnetic fields and by magnetohydrodynamic …

    aachen Repository record for Akustisches Synchronisationsverfahren für die Magnetresonanztomographie (opens in a new tab)