Showing 1 to 9 of 9 for “"Ionization chambers."”.

  1. Dielectric liquid ionization chambers for detecting fast neutrons

    Three ionization chambers with different geometries have been constructed and filled with dielectric liquids for detection of fast neutrons. The three dielectric liquids studied were Tetramethylsilane (TMS), Tetramethylpentane (TMP), and Isooctane, which each have intrinsic properties that make …

    mit Repository record for Dielectric liquid ionization chambers for detecting fast neutrons (opens in a new tab)

  2. Development of a Hybrid Alanine-calorimetry Absorbed-dose Standard for Linac Electron Beams

    … calibrating alanine against secondary standard ionization chambers, with calibrations traceable to primary standard water calorimeter measurements in high-energy electron beams, and subsequently using alanine in low-energy electron beams to determine absorbed dose. Ionization chambers calibrated …

    carleton Repository record for Development of a Hybrid Alanine-calorimetry Absorbed-dose Standard for Linac Electron Beams (opens in a new tab)

  3. Penumbral Distributions For High-energy Radiotherapy Photon Beams: Experimental And Theoretical Determinations

    … of interaction.;Specially-designed cylindrical ionization chambers of varying inside diameters were used to determine the primary penumbral dose distributions in media of varying electron density for Co-60, 6- and 31-MV x-ray beams. The results indicate that the measured penumbral dose …

    uwo Repository record for Penumbral Distributions For High-energy Radiotherapy Photon Beams: Experimental And Theoretical Determinations (opens in a new tab)

  4. Absolute Dose Verification in Intensity Modulated Radiation Fields

    … errors associated with IMRT measurements using ionization chambers in steep dose regions. Some of these errors are due to the lack of electronic lateral equilibrium and detector position-orientation effect. These two limitations were experimentally verified and critiqued in the light of other …

    uiuc Repository record for Absolute Dose Verification in Intensity Modulated Radiation Fields (opens in a new tab)

  5. Measuring Hanbury Brown-Twiss correlations of pions in high-energy nucleus-nucleus collisions

    … of HBT correlations of like-pions, how gaseous ionization chambers used in high-energy physics to measure pion momenta detect the momentum correlations, and we determine the effect the length and time scales involved in detecting HBT have on measurements of the correlations. We also investigate …

    uiuc Repository record for Measuring Hanbury Brown-Twiss correlations of pions in high-energy nucleus-nucleus collisions (opens in a new tab)

  6. Evaluation of Presage® As A 3D Dose Verification to ol In Proton Beams

    … treatment plan verification are film, TLD, and ionization chambers. Such 0D and 2D dosimeters are incapable of fully registering a complete dose volume. This shortcoming has led to an interest in a robust 3D dosimeter with dosimetric accuracy matching that of traditional devices. PRESAGE®, a …

    uthsc Repository record for Evaluation of Presage® As A 3D Dose Verification to ol In Proton Beams (opens in a new tab)

  7. Conceptual Development of Remote Monitoring System for Pressurized Water Reactor Spent Fuel Dry Cask Storage Through Neutron and Gamma Transport Simulations

    … design of the RMS included two fission chambers (to detect neutrons) and one ionization chamber (to detect gamma radiation) enclosed in a polyethylene box with a thin cadmium plate inside, so the sequence of layers starting from the MPC lid was: polyethylene bottom layer, cadmium plate, …

    tamu Repository record for Conceptual Development of Remote Monitoring System for Pressurized Water Reactor Spent Fuel Dry Cask Storage Through Neutron and Gamma Transport Simulations (opens in a new tab)

  8. An ionization chamber for fission fragment analysis

    … a collaborator, we are building and testing an ionization chamber to be used for the SPIDER project which will ultimately take place at the LANSCE facility at Los Alamos National Laboratory. A full spectrum of the pertinent variables dictating the functionality of the ionization chamber have …

    unm Repository record for An ionization chamber for fission fragment analysis (opens in a new tab)

  9. Imaging Techniques for Proton Range Determination in Proton Therapy

    … of the pCT detector is composed of two strip ionization chambers measuring locations and lateral profiles of the exiting beam and a multi-layer ionization chamber (MLIC) measuring the integral depth doses (IDDs), which can be translated to residual energies of the exiting proton beams. A …

    wustl Repository record for Imaging Techniques for Proton Range Determination in Proton Therapy (opens in a new tab)