Showing 1 to 8 of 8 for “"Intramedullary nail"”.
-
Development of a magnetic targeting device applied to interlocking of distal intramedullary nail screw holes
… States. Internal fixation of long bones using intramedullary nails (IMN) has decreased incidence of non-union, allowed shorter hospitalization time, and earlier weight bearing for the patient compared to other fixation methods. Orthopedic surgeons have expressed that one of the most difficult …
-
Intramedullary nailing of tibial non-unions using the suprapatellar approach: a case series
… diaphyseal non-unions of the tibia, including intramedullary (IM) nailing. An infrapatellar entry point with the knee in deep flexion can make this procedure challenging, especially with associated deformity or an obliterated canal. The suprapatellar approach allows nail insertion with the knee …
-
Intramedullary nailing of open tibia and femur fractures through the supra & infrapatellar approach. Is septic arthritis a real concern?
… in the knee following the utilisation of intramedullary nailing techniques. These techniques encompass the supra/infrapatellar approach during tibial nailing and the retrograde approach during femoral nailing. This potential risk stems from the mechanical bridging of the knee joint in both …
-
Induktion und Prophylaxe Implantat assoziierter Knocheninfektionen am Modell eines antiinfektiv beschichteten Marknagels
… bone infections using an antibacterial-coated intramedullary nail – an experimental rabbit model Despite modern peri-operative antimicrobial prophylaxis, bone infections still represent dangerous complications in orthopedic and trauma surgery. Bacterial colonization of implanted material is the …
-
Radiographic Union Score for Tibia (RUST) scoring system in adult diaphyseal femoral fractures treated with intramedullary nailing: an assessment of interobserver and intraobserver reliability
… in diaphyseal femoral fractures treated with intramedullary (IM) nailing. Patients and Methods A total of 60 sets of anteroposterior (AP) and lateral radiographs of diaphyseal femoral fractures treated by reamed IM nailing were randomly selected from a prospectively collected database. The 60 …
-
Schwachstellen-Analyse bei der Entwicklung eines voll implantierbaren Verlängerungsmarknagels
Durch Längendifferenzen der unteren Extremität resultieren Fehlbelastungen, welche den gesamten Bewegungsapparat betreffen. Es resultieren zum Teil erhebliche degenerative Veränderungen, welche nicht nur auf die untere Extremität begrenzt sind. Aus diesem Grund ist die Korrektur einer grösseren …
-
Σχεδιασμός - δομική ανάλυση και βελτιστοποίηση ενδομυελικού ήλου διατατικής οστεογένεσης βασιζόμενου σε ευφυή υλικά με μνήμη
Η παρούσα διδακτορική διατριβή περιγράφει το σχεδιασμό και την ανάπτυξη ενός εκπτυσσόμενου Ενδομυελικού Ήλου Επιμήκυνσης των Μακρών Οστών των Κάτω Άκρων. Η επιμήκυνση των κάτω άκρων είναι μία χειρουργική διαδικασία βαθμιαίας επιμήκυνσης των μακρών οστών των κάτω άκρων και των μαλακών μορίων που τα …
-
Análisis de costo efectividad del uso de la placa de compresión dinámica versus clavo intramedular bloqueado para la fractura proximal de humero en adultos en Colombia
Las fracturas proximales de húmero corresponden al 5% de las fracturas en adultos mayores. La fijación a través de la placa de compresión dinámica es el tratamiento quirúrgico más común, pero se asocia con altas tasas de complicaciones. Los clavos intramedulares bloqueado se convierten en una …