Showing 1 to 6 of 6 for “"Infusion pumps"”.
-
The design of safety-critical medical infusion devices
Intravenous infusion devices - commonly known as infusion pumps - provide clinicians with mechanisms to automate the accurate dosing of potent fluid therapies to critically ill patients. In critical care applications, fluid dosing must be both accurate and safe since unwanted flow disturbance can …
-
Distributed record and replay blackbox for acute care medical devices
… pressure cuff can control the rate by which infusion pumps can deliver pulses of the infused material at precision levels in the order of milliliters or even nanoliters. We have discovered multiple issues with infusion pumps where an adversary is able to attack and modify the nature of the …
-
System Identification and Adaptive Closed-Loop Glucose Control in a Type 1 Diabetic Swine Model
… is experimentally tested using insulin-glucagon infusion pumps to regulate blood glucose online in a diabetic swine model in vivo. As a preliminary study, the pharmacodynamics and stability at room temperature of glucagon in solution were tested in the swine model, thereby qualifying using …
-
Presurgical Behavioral Medicine Evaluation for Implantable Devices for Pain Management: Clinical Effectiveness for Predicting Outcomes
The current study attempts to apply a presurgical psychological screening algorithm to a subset of patients being considered to receive implantable pain management devices, specifically spinal cord stimulators and intrathecal drug delivery systems. The Presurgical Behavioral Medicine Evaluation …
-
Smart IoTs based urine measurement system.
… mostly by electronic devices (e.g. Syringe infusion pumps). At the same time, it is also important to monitor patients’ fluid outputs, in which, urine volume is one of the major components. Currently, it is obtained intermittently (per hour) from urine meters and urine collection bags, and a …
-
Correction of target-controlled infusion following the wrong selection of emulsion concentration of propofol
… against erroneous target-controlled infusions (TCI). Methods: TCIs were started with targeting 4.0 μg/ml of effect-site concentration (Ceff) of propofol, and the emulsion concentrations were selected for 2.0% instead of 1.0% (FALSE1- 2, n = 24), or 1.0% instead of 2.0% (FALSE2-1, n = …