Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 40 for “"Implantable Devices"”.

  1. Development of implantable devices for schizophrenia treatment

    … the nose to the brain. Therefore, intranasal implantable devices containing RIS was developed in this thesis to provide improved treatment of schizophrenia. This approach combines the advantages of implantable drug delivery systems and intranasal drug delivery systems. These implants can …

    qu-belfast Repository record for Development of implantable devices for schizophrenia treatment (opens in a new tab)

  2. Energy-efficient protocol and hardware for security of implantable devices

    … of microelectronic has fueled the development of implantable and wearable devices by enabling them with increased functionality and features. According to the report, global active implantable medical devices (IMDs) market was valued at approximately USD 16.47 billion in 2017 and is expected to …

    mit Repository record for Energy-efficient protocol and hardware for security of implantable devices (opens in a new tab)

  3. Parametric heart modelling and in silico closed-loop validation of implantable devices

    … systems (MCPS), such as cardiac pacemakers and implantable cardioverter defibrillators (ICDs), are life-critical and context-aware. These devices have been increasingly used to provide continuous health-care for patients. The complicated heterogeneous physical dynamics of patients brings …

    auckland-ms Repository record for Parametric heart modelling and in silico closed-loop validation of implantable devices (opens in a new tab)

  4. Presurgical Behavioral Medicine Evaluation for Implantable Devices for Pain Management: Clinical Effectiveness for Predicting Outcomes

    … a subset of patients being considered to receive implantable pain management devices, specifically spinal cord stimulators and intrathecal drug delivery systems. The Presurgical Behavioral Medicine Evaluation (PBME) algorithm was designed to evaluate patients prior to spine surgery. The algorithm …

    utswmed Repository record for Presurgical Behavioral Medicine Evaluation for Implantable Devices for Pain Management: Clinical Effectiveness for Predicting Outcomes (opens in a new tab)

  5. Closed-loop bladder function control for rats using optogenetics

    Implantable devices are continuously proving to be an effective and reliable method of treatment for human patients in clinical settings. One example class of these devices is closed-loop or conditional-triggering implantable devices, which monitor physiological signals and provide necessary …

    uiuc Repository record for Closed-loop bladder function control for rats using optogenetics (opens in a new tab)

  6. Integration of composite nanomaterials into anode and cathode designs

    … electrolyte cathode, designed to be applied in implantable devices, consists of 0.28 mm-thick toray paper as conductive material and Bilirrubin oxidase, the biocatalyst, immobilized silica-gel. The composite nanomaterials and the immobilization techniques utilized in this research would help as …

    unm Repository record for Integration of composite nanomaterials into anode and cathode designs (opens in a new tab)

  7. Nucleation of Cavities in Gels

    Many implantable devices are made of synthetic polymers which upon insertion absorb water, causing the polymer to swell and form a gel (mixture of solid and fluid). Since the swelling leads to an expansion of the polymer, a gel is considered to be a compressible material. A high concentration of …

    umn Repository record for Nucleation of Cavities in Gels (opens in a new tab)

  8. Peripheral Nervous System Modulation with Wireless Cellular Sized Freestanding Injectable Devices

    … efficient, wireless, cellular- sized electronic devices that can be administered in a drug-like fashion. These innovative, substrate-free nanoelectronic devices, termed injectable electronics, can be activated, and controlled using near-infrared (NIR) light, enabling minimally invasive, targeted …

    mit Repository record for Peripheral Nervous System Modulation with Wireless Cellular Sized Freestanding Injectable Devices (opens in a new tab)

  9. Study of the thermal effects induced by magnetic resonance on endocardial leads: numerical models and experimental validation

    … is today precluded to patients bearing active implantable medical devices AIMDs). The great advantages related to this diagnostic modality, together with the increasing number of people benefiting from implantable devices, in particular pacemakers(PM)and carioverter/defibrillators (ICD), is …

    bologna Repository record for Study of the thermal effects induced by magnetic resonance on endocardial leads: numerical models and experimental validation (opens in a new tab)

  10. 0.3V biopotential sensor interface for stress monitoring

    … tight power budget, especially in the case of implantables and health monitoring devices that require long operation lifetime. Exploiting low-voltage techniques in analog design can enable further power savings, which has not been explored much. However, for conventional analog-front-end (AFE) …

    mit Repository record for 0.3V biopotential sensor interface for stress monitoring (opens in a new tab)

  11. ST Monitoring on the Programmer for Implantable Cardioverter Devices

    … of the disease. In order to support the new implantable devices with ST Monitoring capability, the programmer software was updated to support this new feature in the device. This thesis discusses the work on the programmer. Chapter 1 begins with a background of how monitoring technology in an …

    calpoly Repository record for ST Monitoring on the Programmer for Implantable Cardioverter Devices (opens in a new tab)

  12. Cmos Design of an 8-Bit 1MS/S Successive Approximation Register ADC

    … develop smaller and energy efficient biomedical devices which has put stringent requirements on data acquisition systems. These implantable devices are compact and have a very small footprint. Once implanted these devices need to rely on non-rechargeable batteries to sustain a life span of up to …

    calpoly Repository record for Cmos Design of an 8-Bit 1MS/S Successive Approximation Register ADC (opens in a new tab)

  13. Ultrasensitive CMOS-compatible lab-on-a-chip integrated photonic sensors with wideband operation

    … SiC shows biocompatibility for enabling implantable devices. In order to achieve the goal of realizing the essential sensor building block, two high-quality-factor (high-Q) Si3N4 spiral-based coupled-resonator devices and high-Q SiC slot-ring resonators at near-IR wavelengths are …

    gatech Repository record for Ultrasensitive CMOS-compatible lab-on-a-chip integrated photonic sensors with wideband operation (opens in a new tab)

  14. Vertical Contracting In The Us Health Care Industry

    … tend to be concentrated among high-tech implantable devices, and among hospitals for which market concentration in the output market is of the greatest concern. Finally, I study competition in the employer sponsored health insurance market. I estimate a model of supply and demand, which …

    penn Repository record for Vertical Contracting In The Us Health Care Industry (opens in a new tab)

  15. A hardware platform to test analog-to-information conversion and non-uniform sampling

    … and with the increase in the use of biologically implantable devices, the need for the utmost power efficiency is essential. This is where the theory of compressed sensing seems to offer an alternate solution. Instead of solving the problem with the brute force approach of increasing power …

    mit Repository record for A hardware platform to test analog-to-information conversion and non-uniform sampling (opens in a new tab)

  16. Modelling the cost-effectiveness of strategies to treat end-stage heart failure using discrete event simulation

    … first-served basis. Additionally, artificial implantable devices, such as a left ventricular assist device, can buy patients more time on the waiting list or allow patients to become eligible for a HTx when used as a bridge to candidacy. This thesis explicitly considers a resource constrained …

    uts Repository record for Modelling the cost-effectiveness of strategies to treat end-stage heart failure using discrete event simulation (opens in a new tab)

  17. Development of biodegradable implants for sustained drug delivery

    … of drug administration and reduced side effects. Implantable drug delivery benefits from these advantages, but importantly, can be removed if adverse effects necessitate it. In this thesis, reservoir and matrix-type subcutaneous implants were produced and demonstrated adjustable release rates for …

    qu-belfast Repository record for Development of biodegradable implants for sustained drug delivery (opens in a new tab)

  18. Design of a Surgically-Viable Umbo Microphone For Implantable Assistive Hearing Devices

    Assistive hearing devices have enabled the restoration of one the most important senses. These technologies have changed the lives of millions, but there are also hindrances which arise. Today’s hearing devices are bulky, can only be worn during the day, and do not function well in noisy …

    mit Repository record for Design of a Surgically-Viable Umbo Microphone For Implantable Assistive Hearing Devices (opens in a new tab)

  19. Flexible Mems: A Novel Technology To Fabricate Flexible Sensors And Electronics

    … flexible MEMS (Micro Electro Mechanical Systems) devices.</p> <p> MEMS devices and CMOS(Complementary Metal-Oxide-Semiconductor) circuits are traditionally fabricated on rigid substrates with inorganic semiconductor materials such as Silicon. However, it is highly desirable that functional …

    wayne-thes Repository record for Flexible Mems: A Novel Technology To Fabricate Flexible Sensors And Electronics (opens in a new tab)

  20. Self-assembled thin films with tunable release kinetics for biomedical applications

    … more than one drug is involved. Furthermore, for implantable devices biocompatibility and biodegradability are important considerations for minimizing undesirable side effects. This thesis utilizes the layer-by-layer (LbL) approach for the construction of biodegradable thin films that are capable …

    mit Repository record for Self-assembled thin films with tunable release kinetics for biomedical applications (opens in a new tab)

Page 1 of 2