  1. Study of the effect of molten CuCl immersion test on alloys with high Ni-content with and without surface coatings

    … examination of candidate materials following an immersion test in molten CuCl at 500 °C for 100 h. Two alloys, Ni based super-alloy (Inconel 625) and super austenitic stainless steel (AL6XN) were selected as the base metal. There were two types of coating applied to improve the corrosion …

    uoit Repository record for Study of the effect of molten CuCl immersion test on alloys with high Ni-content with and without surface coatings (opens in a new tab)

  2. The effect of post weld heat treatment on the corrosion behaviour of a AA2050T34-FSW

    … function of post weld heat treatment condition. Immersion tests in 0.1 M Nac1 and G110 intergranular tests were performed and the corrsion morphology and the depth of attacks in the different regions of the weld were investigated using FEG/SEM. Polarisation measuresments in the different regions …

    birmingham Repository record for The effect of post weld heat treatment on the corrosion behaviour of a AA2050T34-FSW (opens in a new tab)

  3. System for evaluating effects of immersion in molten copper chloride salts on corrosion resistant coatings

    … to evaluate candidate coatings following an immersion test in molten CuCl at 500°C for a prolonged time. Medium carbon steel was selected as the base metal. There were six types of combination coatings applied to evaluate the corrosion resistance of the generated coatings during the molten …

    uoit Repository record for System for evaluating effects of immersion in molten copper chloride salts on corrosion resistant coatings (opens in a new tab)

  4. Evaluating Leachability of Residual Solids Generated from Unconventional Shale Gas Production Operations in Marcellus Shale

    … to both single extraction (i.e. Shake Extraction Test, SET) and multiple extraction (i.e. Immersion Test, IT) leaching tests. For the shake extraction test, samples were mixed with a specific amount of leaching solution without renewal over a short time period. In the immersion test, samples were …

    vt Repository record for Evaluating Leachability of Residual Solids Generated from Unconventional Shale Gas Production Operations in Marcellus Shale (opens in a new tab)

  5. Ultrasonic array imaging for multi-layer materials in non-destructive testing applications.

    … medical diagnosis, and non-destructive testing. One application for multi-layer imaging is ultrasonic immersion test where the material under test and transducer array are immersed in water. The main imaging challenge in immersion test (or in any multi-layer medium) is that since the …

    uoit Repository record for Ultrasonic array imaging for multi-layer materials in non-destructive testing applications. (opens in a new tab)

  6. A review and development of accelerated test methods for anti-corrosive organic coatings

    … ENM has been used to monitor coatings under immersion conditions, the aim being to assist a paint company develop a set of more environmentally friendly coatings. The immersion test has also incorporated a temperature cycle which proved effective at separating ‘good’ coatings within a short …

    northampton Repository record for A review and development of accelerated test methods for anti-corrosive organic coatings (opens in a new tab)

  7. Tribology of Sliding Contacts Within Plain Bearing Overlays Subject To Corrosion.

    … to many different laboratory-based performance tests for instance, ring-on-disc, pin-on-disc that screen candidate materials as cost effectively as possible prior to much more expensive full engine-based tests. However, it is still uncertain how these lead-free bearing materials behave in …

    bournemouth Repository record for Tribology of Sliding Contacts Within Plain Bearing Overlays Subject To Corrosion. (opens in a new tab)

  8. Study of Titanium based Composite Coatings for Resistance against Molten Aluminium Soldering on H13 Tool Steel

    … shock resistance and wear resistance. In an immersion test, the coated specimens were dipped into molten Al at a temperature of 700 ± 10 °C for different intervals of time. The performance of the coatings was tested in terms of liquid metal corrosion resistance and propensity to Al soldering. …

    waikato-masters Repository record for Study of Titanium based Composite Coatings for Resistance against Molten Aluminium Soldering on H13 Tool Steel (opens in a new tab)

  9. Corrosion Dynamics of Cobalt-Chromium Alloy F-75 Powder

    … Balanced Salt Solution (HBSS) for a 42 day immersion test within an incubating shaker set at 37°C. Samples were removed periodically and analyzed for cobalt and chromium content using Inductive Coupled Plasma – Optical Emission Spectroscopy (ICP-OES). The resulting data gathered allowed for …

    calpoly Repository record for Corrosion Dynamics of Cobalt-Chromium Alloy F-75 Powder (opens in a new tab)

  10. Assessment of Commercial Corrosion Inhibiting Admixtures for Reinforced Concrete

    … pore solutions, • Electrochemical screening tests of special carbon steel specimens in electrochemical corrosion cells containing filtered cement slurry solution. The purposes of the study include: • Determining the influence of a series of commercially available corrosion inhibiting …

    vt Repository record for Assessment of Commercial Corrosion Inhibiting Admixtures for Reinforced Concrete (opens in a new tab)

  11. Long-Term Performance of HDPE Geomembranes as Landfill Liners

    … on both conventional laboratory accelerated immersion tests and simulated landfill liner tests. A 1.5mm HDPE geomembrane was immersed in different synthetic leachates at different temperatures in order to evaluate the effects of leachate chemical constituents on the depletion of antioxidants. …

    queens Repository record for Long-Term Performance of HDPE Geomembranes as Landfill Liners (opens in a new tab)

  12. Measurement of optical properties of molten salts and metallic compounds for advanced solar and nuclear systems

    … 10°, 40°, and 70° after an 8-day molten salt immersion test. The reflectivity was measured to be less than 10% for the solar spectrum.

    mit Repository record for Measurement of optical properties of molten salts and metallic compounds for advanced solar and nuclear systems (opens in a new tab)

  13. Evaluation of the effects of molten CuCl on corrosion resistant coatings

    … coatings. Different coating materials were tested in high temperature molten copper chloride environment to evaluate the coating performance. Super hard steel, Diamalloy 4006, YSZ (ZrO2 18TiO2 10Y2O3) and alumina are the candidate materials selected for corrosion test. High Velocity Oxy fuel …

    uoit Repository record for Evaluation of the effects of molten CuCl on corrosion resistant coatings (opens in a new tab)

  14. Durability and Adhesion of a Model Epoxy Adhesive Bonded to Modified Silicon Substrates

    … in a stronger SCA-Si attachment. Three different tests were employed to determine adhesion and durability of the model epoxy/SCA/SiO2/Si bonded specimens. The immersion test qualitatively evaluates the bond durability for various systems exposed to different chemical and thermal conditions. …

    vt Repository record for Durability and Adhesion of a Model Epoxy Adhesive Bonded to Modified Silicon Substrates (opens in a new tab)

  15. Solvent induced microcracking in high performance polymeric composites

    … material system were subjected to one of three immersion tests. The first immersion test involved soaking composite specimens previously prepared with different polishing techniques in dye penetrant. In the second test, specimens were immersed in the individual components of the dye penetrant. …

    vt Repository record for Solvent induced microcracking in high performance polymeric composites (opens in a new tab)

  16. Phenotypic variation and thermoregulation of the human hand

    … to thermodynamic principles, which have not been tested in vivo. This study sought to determine the influence of hand and digit proportions on heat loss from the hands directly, the additional anthropometric factors that may affect this relationship, and the impact of variation in hand proportions …

    cambridge Repository record for Phenotypic variation and thermoregulation of the human hand (opens in a new tab)

  17. Rapid assessment of the potential chloride resistance of structural concrete

    … Of the three allowed methodologies, the immersion test was carried out. At least two water-cement ratios were produced for each mix design to enable normalisation of the results. The performance of concrete was compared on the basis of equal compressive strength, i.e. 40 and 50 N/mm2 and …

    dundee Repository record for Rapid assessment of the potential chloride resistance of structural concrete (opens in a new tab)

  18. Physical performance and durability evaluation of rubberized concrete

    … procedure. Then, three types of durability test were conducted namely, 1) Chloride ion diffusion test, 2) Abrasion wear resistance test, and 3) Freezing and thawing test. Up-to-date, many successful achievements were reported by researchers around the world. However, in Asian cases, very …

    uthm Repository record for Physical performance and durability evaluation of rubberized concrete (opens in a new tab)

  19. An Analysis of Microstructure and Corrosion Resistance in Underwater Friction Stir Welded 304L Stainless Steel

    … in UWFSWs was evaluated using double loop EPR testing and oxalic acid electro-etched metallography. Results were compared to base metal, ambient FSW, and arc welds. Upper and lower sensitization localization bands were identified in the UWFSWs. Although higher sensitization levels were present …

    byu Repository record for An Analysis of Microstructure and Corrosion Resistance in Underwater Friction Stir Welded 304L Stainless Steel (opens in a new tab)