  1. Design and Construction of a Guarded Hot Box Facility for Evaluating the Thermal Performance of Building Wall Materials

    … of this study was to design and build a guarded hot box to test the R-Value of building materials. The Riverside Energy Efficiency Laboratory is looking to expand their testing capabilities by including this service. Eventually, the laboratory will become energy star certified. A guarded hot box

    tamu Repository record for Design and Construction of a Guarded Hot Box Facility for Evaluating the Thermal Performance of Building Wall Materials (opens in a new tab)

  2. The Effect of Green Insulation Standards on Moisture Accumulation within Framing of Residential Structures

    … condensation. This research used a single-sided hot-box design to measure moisture content of wood framing during a 60-day period. The resulting moisture content of the wood framing was compared as tested with spray-applied cellulose and polyurethane versus fiberglass batt insulation. The average …

    vt Repository record for The Effect of Green Insulation Standards on Moisture Accumulation within Framing of Residential Structures (opens in a new tab)

  3. Structural and Steady-State Thermal Experimental Investigations of an Insulated Sandwich Panel

    … specimens were tested in a purpose-built hot box apparatus under steady-state conditions. GFRP connectors showed minimal thermal bridging regardless of cross-section area or spacing, while steel connectors demonstrated significant thermal bridging in recorded temperatures despite a smaller …

    queens Repository record for Structural and Steady-State Thermal Experimental Investigations of an Insulated Sandwich Panel (opens in a new tab)