Showing 1 to 5 of 5 for “"Fine particle dose (FPD)"”.
-
Development of Afatinib lipid nanoparticles targeting non small cell lung cancer
… method. The obtained liposomes had a small particle size of less than 50 nm with a low polydispersibilty index and acceptable zeta potential. The highest Encapsulation Efficiency (EE%) of AFT reached 43.20%, 50.20%, and 52.01% for NL (Non targeting liposomes), PSL, CL, respectively at the …
-
Investigations to identify the influence of the inhalation manoeuvre on the ex-vivo dose emission and the in-vitro aerodynamic dose emission characteristics of dry powder inhalers: Studies to identify the influence of inhalation flow, inhalation volume and the number of inhalations per dose on the ex-vivo dose emission and the in-vitro aerodynamic dose emission characteristics of dry powder inhalers.
… energy to generate and disperse aerosol particles in the respirable range ¿5¿m during inhalation. The patient's inspiratory effort together with the resistance inside the device creates this energy. Different inhalers provide varying degrees of resistance to inhalation flow and require …
-
Relative Bio-Equivalence of Salbutamol MDIs Without and With the Attached Spacers. Development and validation of novel HPLC methods for the determination of salbutamol (and terbutaline) in urine excreted post-inhalation for bioequivalence and pharmacokinetic studies of Salbutamol MDIs
… in-vivo performance of three salbutamol metered dose inhalers (MDIs): Ventolin Evohaler (Evo), Airomir (Airo) and Salamol. In the in-vitro studies, critical quality attributes of the MDI using an Andersen cascade impactor (ACI) were examined and included measurement of fine particle dose (FPD) …
-
Investigations to identify the influence of the inhalation manoeuvre on the ex-vivo dose emission and the in-vitro aerodynamic dose emission characteristics of dry powder inhalers: Studies to identify the influence of inhalation flow, inhalation volume and the number of inhalations per dose on the ex-vivo dose emission and the in-vitro aerodynamic dose emission characteristics of dry powder inhalers.
… energy to generate and disperse aerosol particles in the respirable range ¿5¿m during inhalation. The patient's inspiratory effort together with the resistance inside the device creates this energy. Different inhalers provide varying degrees of resistance to inhalation flow and require …
-
Relative bioavailability of terbutaline to the lungs following inhalation using different methods.
… the in-vitro characteristics of the emitted dose by these inhalation methods. Two new robust, accurate and sensitive high performance liquid chromatography methods for the determination of terbutaline in aqueous and urine samples were validated in accordance with the FDA and ICH guidelines. …