Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 6 of 6 for “"Fault Current Limiter"”.

  1. A comprehensive overview, behavioral model and simulation of a Fault Current Limiter

    … distribution system, a higher operating current state leading to increased fault current levels is attained. Hence, the relay co-ordination is disturbed and equipments such as feeders and circuit breakers need to be replaced with higher rating so that they can handle the new currents …

    vt Repository record for A comprehensive overview, behavioral model and simulation of a Fault Current Limiter (opens in a new tab)

  2. Resistive-type Superconducting Fault Current Limiter (RSFCL) and Its Application in Power Systems

    … capacity, leading to a sharp rise in the fault current. High fault current levels have severe impact on power systems. They can increase the likelihood of overcurrent damage, which may destroy electrical facilities or even cause system blackout. The resistive-type superconducting fault

    cambridge Repository record for Resistive-type Superconducting Fault Current Limiter (RSFCL) and Its Application in Power Systems (opens in a new tab)

  3. Study of superconducting fault current limiters in power systems

    … of failures in power systems are short-circuit faults. Short- circuit currents can grow thousands of times larger than normal system operating currents, i.e., within milliseconds. This places enormous thermal and mechanical stress on existing transmission infrastructure and may even cause …

    cambridge Repository record for Study of superconducting fault current limiters in power systems (opens in a new tab)

  4. Specification, Placement, and Control of Fault Current Limiters In Power Systems

    … dissertation focuses on the application of fault current limiters (FCLs) in power systems. The formula for the maximum first-peak fault current is derived to assist in specifying inductive FCLs. The specification process can be used to design and select proper FCL devices in a particular …

    south-carolina Repository record for Specification, Placement, and Control of Fault Current Limiters In Power Systems (opens in a new tab)

  5. Kühlung eines resistiven HTSL-Kurzschlussstrombegrenzers mit einer Gemisch-Joule-Thomson-Kältemaschine

    Die vorliegende Arbeit beschäftigt sich nach der Analyse und Optimierung der Stromzuführungen auf Flüssigstickstoff-Temperaturniveau, hauptsächlich mit der Untersuchung einer Gemisch-Stickstoff-Kaskade als Kälteversorgungssystem eines resistiven HTSL-Kurzschlussstrombegrenzers. Unter einem …

    qucosa-diss

  6. DFIG-Based Split-Shaft Wind Energy Conversion Systems

    … handles the regular operation well. However, the fault conditions may expose conditions on the converter and push it to its limits. Therefore, four different protection circuits are employed, and their effects are investigated and compared to evaluate their performance. These four protection …

    iupui Repository record for DFIG-Based Split-Shaft Wind Energy Conversion Systems (opens in a new tab)