Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 14 of 14 for “"Failure mode analysis"”.

  1. Characterization and Failure Mode Analysis of Cascode GaN HEMT

    … GaN HEMT, an accurate behavior-level simulation model is developed in this thesis. The packaging related parasitic inductance, including both self-inductance and mutual-inductance, are extracted based on finite element analysis (FEA) methods. Then the accuracy of the simulation model is verified …

    vt Repository record for Characterization and Failure Mode Analysis of Cascode GaN HEMT (opens in a new tab)

  2. Failure mode analysis of ceramic heating elements and pre-chamber ignition of aviation fuels

    Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2025-03-28 without embargo terms

    uiuc Repository record for Failure mode analysis of ceramic heating elements and pre-chamber ignition of aviation fuels (opens in a new tab)

  3. Gas lift valve failure mode analysis and the design of a thermally-actuated positive-locking safety valve

    Gas-lifted oil wells are susceptible to failure through malfunction of gas lift valves. This is a growing concern as offshore wells are drilled thousands of meters below the ocean floor in extreme temperature and pressure conditions and repair and monitoring become more difficult. Gas lift valves …

    mit Repository record for Gas lift valve failure mode analysis and the design of a thermally-actuated positive-locking safety valve (opens in a new tab)

  4. Assessment of fire and explosion hazards in large-scale battery energy storage systems intended for Namibian green hydrogen projects

    … research investigates the specific risks and failure modes associated with BESS, aiming to provide safety solutions and guidelines for their broader application in renewable energy projects. The study begins with a comprehensive literature review, identifying the primary causes of …

    namibia Repository record for Assessment of fire and explosion hazards in large-scale battery energy storage systems intended for Namibian green hydrogen projects (opens in a new tab)

  5. System redesign within complex, technically integrated products

    … identification of critical target systems, a failure mode analysis of the identified system(s), use of benchmarking and/or statistical tools as necessary to characterize features that can be utilized to improve system performance, and finally, conceptual design activity to implement such …

    mit Repository record for System redesign within complex, technically integrated products (opens in a new tab)

  6. Rolling contact orthopaedic joint design

    … and complications associated with joint/tissue failure. A deterministic approach to joint design is taken to elucidating six functional requirements for a prosthetic tibiofemoral joint based on anatomical observations of human knee kinetics and kinematics. Current prostheses have a high …

    mit Repository record for Rolling contact orthopaedic joint design (opens in a new tab)

  7. Failure Modes Analysis and Protection Design of a 7-level 22 kV DC 13.8 kV AC 1.1 MW Flying Capacitor Converter Based on 10 kV SiC MOSFET

    … levels, and the critical nature of the loads, a failure in a high-power converter can incur significant costs, long service downtime, and safety risks to personnel. Hence, understanding the failure modes of these converters is essential for designing protections and mitigation strategies to …

    vt Repository record for Failure Modes Analysis and Protection Design of a 7-level 22 kV DC 13.8 kV AC 1.1 MW Flying Capacitor Converter Based on 10 kV SiC MOSFET (opens in a new tab)

  8. Development of musculoskeletal models for the design and the pre-clinical validation of hip resurfacing prosthesis

    … only by predicting the possible scenario of failure, to date the understanding of the implant quality is poorly pre-clinically addressed. Thus revision is the only delayed and reliable end point for assessment. The aim of the present work was to model the musculoskeletal system so as to …

    bologna Repository record for Development of musculoskeletal models for the design and the pre-clinical validation of hip resurfacing prosthesis (opens in a new tab)

  9. Stability of Levees and Floodwalls Supported by Deep-Mixed Shear Walls: Five Case Studies in the New Orleans Area

    … more rapid construction. Suitable methods for analysis and design of these systems are needed to ensure that the DMM technology is properly applied. DMM shear walls oriented perpendicular to the levee alignment are an effective arrangement for supporting unbalanced lateral loads. Shear walls …

    vt Repository record for Stability of Levees and Floodwalls Supported by Deep-Mixed Shear Walls: Five Case Studies in the New Orleans Area (opens in a new tab)

  10. Analysis and Design for a High Power Density Three-Phase AC Converter Using SiC Devices

    … the given conditions. Thirdly, a novel average model is developed for the selected topology, and used for devising a carrier-based control approach with simple calculation and good regulation performance. Fourthly, the converter failure mode operation and corresponding protection approaches are …

    vt Repository record for Analysis and Design for a High Power Density Three-Phase AC Converter Using SiC Devices (opens in a new tab)

  11. Analysis and Design of Paralleled Three-Phase Voltage Source Converters with Interleaving

    … with interleaving is developed. All the analysis and proposed control methods are investigated with the goal of maximizing the benefit of interleaving based on system requirement. The dissertation is divided into five sections. Firstly, a complete analysis studying the impact of …

    vt Repository record for Analysis and Design of Paralleled Three-Phase Voltage Source Converters with Interleaving (opens in a new tab)

  12. Planar metallization failure modes in integrated power electtonics modules

    … power density are the latest trends in modern power electronics development. In order to meet the requirements of higher frequency and higher power density in power electronics applications, planar interconnections are utilized to achieve a higher integration level. Power switching …

    vt Repository record for Planar metallization failure modes in integrated power electtonics modules (opens in a new tab)