Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"Electrometer"”.

  1. An Electrometer Design and Characterization for a CubeSat Neutral Pressure Instrument

    … of an ionization chamber and a logarithmic electrometer circuit. The Rev. 1 SNeuPI electrometer prototype does not function as designed. A Rev. 2 electrometer circuit must be designed and its performance characterized across specified operating temperature and input current ranges. This …

    vt Repository record for An Electrometer Design and Characterization for a CubeSat Neutral Pressure Instrument (opens in a new tab)

  2. Advanced Faraday cage measurements of charge, short-circuit current and open-circuit voltage

    … electrode of the electrode chamber with the electrometer, as water condensed. Positive current could have been produced by the evaporation of moisture from the center electrode of the electrode chamber. Dew point analysis is performed to show that for water to condense on metallic surfaces, …

    mit Repository record for Advanced Faraday cage measurements of charge, short-circuit current and open-circuit voltage (opens in a new tab)

  3. Developing a labview based thermally stimulated current (tsc) controller to measure residual charge in electrospinning

    … controller encapsulates the temperature and the electrometer control using RS- 485 and GPIB interfaces. The controller outputs a Temperature-Current plot which is the Thermally Stimulated Current spectrum. The current observed at the melting point of the electrospun material is a direct measure …

    njit Repository record for Developing a labview based thermally stimulated current (tsc) controller to measure residual charge in electrospinning (opens in a new tab)

  4. Characteristics of particles downstream of a partially failed diesel particulate filter.

    … An electrostatic precipitator, DMA, electrometer and CPC were used to evaluate the aerosol charge distribution. Downstream measurements were repeated as the filter was progressively failed in a series of steps. These measurements were then used to evaluate the response of the …

    umn Repository record for Characteristics of particles downstream of a partially failed diesel particulate filter. (opens in a new tab)

  5. Single-layer transport measurements of bilayer 2D electron and hole systems in GaAs heterostructures

    … (2DES), we use the lower 2DES as a quantum Hall electrometer to measure the chemical potential of the upper 2DES. We track the evolution of the Landau levels in the upper 2DES, and extract an effective mass that is consistent with previous values. Secondly, we investigated the hysteresis in the …

    unsw Repository record for Single-layer transport measurements of bilayer 2D electron and hole systems in GaAs heterostructures (opens in a new tab)

  6. The Influence of Food Physical Properties on Transfer Efficiency and Adhesion in a Tumble Drum Process

    … exiting the test cell was measured using an electrometer (Model 614, Keithley Instruments, Inc., Cleveland, OH) and theresistivity was determined by the following equation: ¿ = (KV)/I, where ¿= resistivity, K is the cell constant which is equal to 0.014, V= the voltage applied to the test …

    ohiolink Repository record for The Influence of Food Physical Properties on Transfer Efficiency and Adhesion in a Tumble Drum Process (opens in a new tab)

  7. Particle Charging and Classification: The Mass Mobility Aerosol Spectrometer (M2AS)

    … address this challenge, the Mobility Separator Electrometer (MSE) is introduced—a new classifier designed to measure average charge and average particle electrical mobility when combined with a condensation particle counter (CPC). The MSE enhances the performance of unipolar charger-classifier …

    cambridge Repository record for Particle Charging and Classification: The Mass Mobility Aerosol Spectrometer (M2AS) (opens in a new tab)

  8. Virtuální laboratoř na bázi JAVA a LABVIEW

    Dielektrické materiály jsou použivány v elektronice i v elektrotechnice. Jako jejich základní vlastnost může považovat změnu jejich charakteristik během jejich životnosti. Změny jsou způsobeny namáhaním materiálu vyvolané elektrickými či teplotími vlivy. Možnost jak určit průběh jejich …

    brno-tech Repository record for Virtuální laboratoř na bázi JAVA a LABVIEW (opens in a new tab)

  9. Intensity Modulated Radiation Therapy (IMRT) versus Conventional Methods in Treatment of Breast Cancer

    Made available in DSpace on 2017-07-06T18:48:10Z (GMT). No. of bitstreams: 3 Garada_Masab_H_MS.pdf: 25651236 bytes, checksum: 73bdf7e5f39d5df868694b4da036d02f (MD5) Garada_Masab_H_MS_ABS.pdf: 430262 bytes, checksum: 605229f2df5957921ac144e978f18848 (MD5) license.txt: 4813 bytes, checksum: …

    uiuc Repository record for Intensity Modulated Radiation Therapy (IMRT) versus Conventional Methods in Treatment of Breast Cancer (opens in a new tab)