Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"Differential Protection"”.

  1. A novel configuration of all-optical differential protection scheme

    … have stimulated the development of the optical differential protection schemes for busbar protection. However, these optical differential schemes adopt mixed optical-numerical processes that use a platform based on modern numerical/microprocessor protection schemes. Therefore, opportunities to …

    strathclyde Repository record for A novel configuration of all-optical differential protection scheme (opens in a new tab)

  2. An intelligent communication controller for the VME bus

    … of the communication system used in a current differential protection scheme for power distribution systems.

    vt Repository record for An intelligent communication controller for the VME bus (opens in a new tab)

  3. New Differential Zone Protection Scheme Using Graph Partitioning for an Islanded Microgrid

    … challenges on power systems. Microgrid protection is one of the technical challenges implicit in the deployment of microgrids. These challenges occur as a result of the unique properties of microgrid networks in comparison to traditional electrical networks. Differential protection is a …

    vt Repository record for New Differential Zone Protection Scheme Using Graph Partitioning for an Islanded Microgrid (opens in a new tab)

  4. Applicability of the Charter in the Healthcare Context Through the Lens of Vaccination-or-mask Policies

    … its Charter obligations, and may lead to a differential protection of rights across the provinces. A solution is proposed that requests the court to consider a more holistic approach to characterizing an entity as governmental or not. Also, it may be useful to recognize that healthcare as a …

    toronto-retro Repository record for Applicability of the Charter in the Healthcare Context Through the Lens of Vaccination-or-mask Policies (opens in a new tab)

  5. Protection system representation in the Electromagnetic Transients Program

    … the addition of the few critical elements of a protection system to the Electromagnetic Transients Program (EMTP). The EMTP is one of the most widely used programs for the simulation of transients in power systems. The EMTP contains models for almost every major power system component. A …

    vt Repository record for Protection system representation in the Electromagnetic Transients Program (opens in a new tab)

  6. Assessment Of Overcurrent Relay Coordination In A Microgrid With High PV Penetration Deployment

    … or islanded) would jeopardize the current-based protection schemes. In view of the above issues related to microgrid protection, this thesis discusses the inadequacy of the conventional protection schemes, fault behavior of inverter interfaced distributed sources and impact on the coordination of …

    umkc Repository record for Assessment Of Overcurrent Relay Coordination In A Microgrid With High PV Penetration Deployment (opens in a new tab)

  7. Advanced microprocessor based intelligent relay for multifunction protection system

    … desire for additional tasking. In power protection field, there have been many cases where protection theories and techniques have played an important role. With the progress of protection techniques, there are now many applications for protection with increased performance. However, …

    vu-aus Repository record for Advanced microprocessor based intelligent relay for multifunction protection system (opens in a new tab)

  8. The Hydroxamate Reaction of Aminoacyl-tRNA Synthetases

    … enzymes, and it is interpreted to reflect the differential protection that the aminoacyl-tRNA synthetases afford their respective aminoacyladenylates. The most extreme case in this regard is the threonyl-tRNA synthetase, which does not catalyze threonine hydroxamate formation. Therefore, this …

    rockefeller Repository record for The Hydroxamate Reaction of Aminoacyl-tRNA Synthetases (opens in a new tab)

  9. BEHAVIOR OF BUSBAR DIFFERENTIAL RELAYS WITH AIR-GAP CORE CURRENT TRANSFORMERS

    … Then, two commercially available busbar differential relays with CT saturation detection logic were subjected to the output waveforms of solid-core and air- gap core CTs. After testing about hundred scenarios on each relay, it is concluded that first, there is no difference in the relays’ …

    uwo Repository record for BEHAVIOR OF BUSBAR DIFFERENTIAL RELAYS WITH AIR-GAP CORE CURRENT TRANSFORMERS (opens in a new tab)

  10. Data-driven Protection of Transformers, Phase Angle Regulators, and Transmission Lines in Interconnected Power Systems

    … and ensuring their safety is a primary issue. Differential relays are commonly employed to protect transformers, whereas distance relays are utilized to protect transmission lines. Magnetizing inrush, overexcitation, and current transformer saturation make transformer protection a challenge. …

    syracuse-diss Repository record for Data-driven Protection of Transformers, Phase Angle Regulators, and Transmission Lines in Interconnected Power Systems (opens in a new tab)