Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 34 for “"Cooling tower"”.

  1. Parametric study of stresses in cooling-tower shells

    … made in studying the structural behaviour of cooling tower shells, focusing more on the effect of wind on the structure and shape imperfections. However, little has been investigated on the most basic loading condition, i.e. self-weight load. This thesis focuses on a cooling tower with uniform …

    cape-town Repository record for Parametric study of stresses in cooling-tower shells (opens in a new tab)

  2. General equation for predicting cooling tower approach temperatures at lower wetbulbs

    Cooling tower approach temperature is the difference in leaving water temperature and entering air wet-bulb temperature. Cooling tower manufacturers describe the design capacity with water volumetric flow, entering water temperature, leaving water temperature, and entering air wet-bulb temperature. …

    alabama Repository record for General equation for predicting cooling tower approach temperatures at lower wetbulbs (opens in a new tab)

  3. Performance tests and cooling effect distribution of the V.P.I. forced draft cooling tower

    Test data of forced draft cooling towers is all too meager, and that available is, in many instances, incomplete. It is the opinion of the authors that putting cooling tower design on a rational basis can be brought about only by two methods. Either complete and intensive study of all existing …

    vt Repository record for Performance tests and cooling effect distribution of the V.P.I. forced draft cooling tower (opens in a new tab)

  4. Stability behaviour and dynamic response of cooling towers subjected to wind loading

    … parametric analysis is presented for various cooling tower shell geometries. The shells are subjected to increasing wind pressures (speeds) to observe the trends in the critical buckling pressures/speeds at which the shell first buckles and the corresponding buckling modes. The cooling tower's …

    cape-town Repository record for Stability behaviour and dynamic response of cooling towers subjected to wind loading (opens in a new tab)

  5. Heat Transfer Enhancement using Iron Oxide Nanoparticles

    … for heat transfer properties in industrial cooling systems. The nanofluids either had 30 nm particles with a wide size distribution to include particles greater than 1 micrometer or 15 nm particles with greater than 95% of the particles less than 33 nm. Calorimetry and thermal circuit …

    vcu Repository record for Heat Transfer Enhancement using Iron Oxide Nanoparticles (opens in a new tab)

  6. Software for fault detection in HVAC systems in commercial buildings

    … order faults such as simultaneous heating and cooling and imbalanced airflows within several large air-handling units were targeted. Savings of around $22,500 were predicted when the fault of simultaneous heating and cooling was occurring over the entire month in an air handler. Some of the …

    mit Repository record for Software for fault detection in HVAC systems in commercial buildings (opens in a new tab)

  7. Optimal Allocation of Building Cooling Loads to Chilled Water Plant Equipment

    … a chiller plant consisting of liquid chillers, cooling towers and pumps. To meet the changing demand for cooling, most buildings have automated systems that control the operation of the chilled water plant. The system that controls the chilling equipment selects the temperatures of the water …

    uiuc Repository record for Optimal Allocation of Building Cooling Loads to Chilled Water Plant Equipment (opens in a new tab)

  8. Environmental regulation of the growth, physiology and virulence of <i>Legionella pneumophila</i>

    … to species level. <br></br><br></br>Evaporative cooling towers are a significant source of Legionnaires' disease accounting for the majority of outbreak cases in the United Kingdom. In the second part of this study a microbiologically-contained, fully-functional evaporative cooling tower was …

    the-open-u Repository record for Environmental regulation of the growth, physiology and virulence of <i>Legionella pneumophila</i> (opens in a new tab)

  9. STUDYING THE PERFORMANCE OF A QUAD-GENERATION SYSTEM WITH STORAGE FOR IMPROVED ENERGY EFFICIENCY

    … utilize dissipated heat to produce desired cooling and heating, along with excellent economic feasibility and emission reduction performance. This study aims to comprehensively investigate and optimize the performance of a Quad-generation system from the perspectives of both fundamental …

    nus Repository record for STUDYING THE PERFORMANCE OF A QUAD-GENERATION SYSTEM WITH STORAGE FOR IMPROVED ENERGY EFFICIENCY (opens in a new tab)

  10. Beitrag zur numerischen Analyse der Schädigungsmechanismen von Naturzugkühltürmen

    … progressive damage process of natural draught cooling towers is analysed numerically. A non-linear composite material model for the reinforced concrete is formulated. Regarding the durability a special attention is paid to the cracking process and the determination of the crack width. Within …

    aachen Repository record for Beitrag zur numerischen Analyse der Schädigungsmechanismen von Naturzugkühltürmen (opens in a new tab)

  11. The architectural impact of using ground-source heat pumps in commercial buildings in Las Vegas

    … a secondary means of heat disposal such as a cooling tower or absorption chiller may not be the most suitable HVAC system type for commercial office buildings in Las Vegas. (Abstract shortened by UMI.).

    unlv Repository record for The architectural impact of using ground-source heat pumps in commercial buildings in Las Vegas (opens in a new tab)

  12. Role of the Curved Parametric Element in Linear Analysis of Thin Rotational Shells.

    … perspex models in the shape of a cooling Tower were formed and tested in order to verify the existence of any correlation between theoretical and experimental results. These tests covered linear, small displacement response of the model for both static and dynamic …

    southwales Repository record for Role of the Curved Parametric Element in Linear Analysis of Thin Rotational Shells. (opens in a new tab)

  13. Conceptual design of an SOx scrubber system utilizing plant waste

    The use of ash pond water and cooling tower blowdown as possible SO<sub>x</sub> scrubber liquors has been studied. Information on analysis of ash pond water indicates that this method may be feasible. lt was found that ash from the furnace contained salts which could be used to absorb …

    vt Repository record for Conceptual design of an SOx scrubber system utilizing plant waste (opens in a new tab)

  14. A water and greenhouse gas inventory for hygroscopic and conventional evaporative building-scale cooling systems

    … ventilation, and air conditioning (HVAC) cooling tower technology with the goal of reducing water usage. In this study, direct and indirect water usage and greenhouse gas emissions were quantified to analyze the tradeoffs associated with transitioning from a conventional wet-cooling HVAC …

    uiuc Repository record for A water and greenhouse gas inventory for hygroscopic and conventional evaporative building-scale cooling systems (opens in a new tab)

  15. Methodology for characterization of representativeness uncertainty in performance indicator measurements of thermal and nuclear power plants

    … tracers (Case Study 2), The simulation of cooling tower deformation using a Photomodeler (Case Study 3) and the NOx emission measurement from a Combined Cycle Gas Turbine (Case Study 4). In Case Study 1, the non-parametric bootstrap method was used to quantify sampling, iterative and …

    mit Repository record for Methodology for characterization of representativeness uncertainty in performance indicator measurements of thermal and nuclear power plants (opens in a new tab)

Page 1 of 2