Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 84 for “"Contact Pressure"”.

  1. CONTACT PRESSURE MEASUREMENT

    … techniques do not indicate the actual gasket pressure in the interfaces of the joint. An extensive literature survey was carried out to identify suitable sensing material that could be configured into a miniature sensor to be inserted between the two interfaces of bolted joints for the purpose …

    nus Repository record for CONTACT PRESSURE MEASUREMENT (opens in a new tab)

  2. Contact Pressure Distribution Optimization

    A novel design technique that is used to optimize contact pressure distribution was introduced and investigated. The primary objective of this design tool, called the Predicted Displacement Method, was to provide a calculated contact surface shape alteration of a contact body that induces a uniform …

    vt Repository record for Contact Pressure Distribution Optimization (opens in a new tab)

  3. Zinc pot bearing material wear rate as a function of contact pressure and velocity

    … zinc-pot bearing materials as a function of contact pressure and velocity. A small laboratory size-testing machine was developed for this purpose. This machine measures the wear of bearing material samples, submerged in a cup of zinc, in the form of a 1-inch diameter ball rotating against a …

    wvu Repository record for Zinc pot bearing material wear rate as a function of contact pressure and velocity (opens in a new tab)

  4. Development of a Human Tibiofemoral Joint Finite Element Model to Investigate the Effects of Obesity and Knee Malalignment on Joint Contact Pressure

    … (OA). Excess body weight generates greater joint contact forces at the knee; however, obese individuals alter their gait to decrease joint contact forces. Knee malalignment has been identified as a strong mediating factor between obesity and knee OA progression. Excess body weight acting on a …

    calpoly Repository record for Development of a Human Tibiofemoral Joint Finite Element Model to Investigate the Effects of Obesity and Knee Malalignment on Joint Contact Pressure (opens in a new tab)

  5. Subject-Specific Finite Element Predictions of Knee Cartilage Pressure and Investigation of Cartilage Material Models

    … loads, stresses and strains, and joint contact area and pressure. Abnormal cartilage contact pressure is considered a risk factor for incidence and progression of OA. For this study, three subject-specific tibiofemoral knee FE models containing accurate geometry were developed from …

    calpoly Repository record for Subject-Specific Finite Element Predictions of Knee Cartilage Pressure and Investigation of Cartilage Material Models (opens in a new tab)

  6. A hybrid haptic stimulation prosthetic wearable device to recover the missing sensation of the upper limb amputees

    … system that is capable in sensing the contact pressure, the surface texture, and the temperature, simultaneously, was designed for a prosthetic hand to provide a tactile sensation to amputation patients. In addition, the haptic system was developed to enable the prosthetic’s users to …

    uthm Repository record for A hybrid haptic stimulation prosthetic wearable device to recover the missing sensation of the upper limb amputees (opens in a new tab)

  7. Structural health monitoring of bolted joints using thermal contact resistance and ultrasonic signals

    … include using ultrasonic signals and thermal contact resistance metrics correlated to contact pressure to assess the joints integrity. Moreover, contact pressure distribution at the joint surface was examined using pressure sensitive films. Experimental measurements showed that there were …

    unm Repository record for Structural health monitoring of bolted joints using thermal contact resistance and ultrasonic signals (opens in a new tab)

  8. Finite element analysis of total knee replacement considering gait cycle load and malalignment

    … different performance on movement and contact pressure distribution in the tibio-femoral contact surfaces. More contact areas were found in the mobilebearing implant than in the fixed-bearing implant, but the maximum contact pressures were almost the same in both. The thickness of the …

    wlv Repository record for Finite element analysis of total knee replacement considering gait cycle load and malalignment (opens in a new tab)

  9. Response of grooved composite laminates to out-of-plane contact loading via numerical models

    … of grooved composite laminates to out-of-plane contact loading is examined using numerical modeling through the consideration of contact pressure and stresses within the laminate, with particular focus on the area local to the groove. Finite element analysis is employed via ABAQUS, a commercial …

    mit Repository record for Response of grooved composite laminates to out-of-plane contact loading via numerical models (opens in a new tab)

  10. Multi-scale scratching in chemical-mechanical polishing

    … thesis presents scratching models by analytical contact mechanics, finite element analysis, and statistical methods. First, scratching due to hard, abrasive particles was modeled and expressions for the maximum and minimum scratch width and depth were determined. Second, scratching of a hard …

    mit Repository record for Multi-scale scratching in chemical-mechanical polishing (opens in a new tab)

  11. A study of mechanical behaviour of the double-row tapered ring bearing for the main shaft of a direct-drive wind turbine

    … have been proposed for calculating the contact force and pressure distribution of double-row TRBs. Nevertheless, most of the existing studies failed to consider angular misalignment between the inner and outer rings as well as the friction force between the rollers and raceways. A …

    uts Repository record for A study of mechanical behaviour of the double-row tapered ring bearing for the main shaft of a direct-drive wind turbine (opens in a new tab)

  12. Pole tip recession in linear tape systems

    … may be achieved in future systems. Water vapour pressure or Normalized Water Content (NWC) rather than the Relative Humidity (RH) values (as are used almost universally in this field) determined the extent of PTR and stain (if produced) in linear heads. Approximately linear dependencies were …

    aston Repository record for Pole tip recession in linear tape systems (opens in a new tab)

  13. Evaluation of image receptor angulation during mediolateral oblique positioning for optimised pressure and area distribution in mammography

    … angle of IR during MLO positioning for optimised pressure and area distribution; this in turn may help reduce pain and discomfort associated with the procedure.MethodThe experimental work described in this report is in two phases. Phase one was an anthropomorphic phantom study to establish a …

    salford Repository record for Evaluation of image receptor angulation during mediolateral oblique positioning for optimised pressure and area distribution in mammography (opens in a new tab)

  14. A comprehensive analytical model for pneumatic tires

    … model is composed of two parts--modeling of the contact mechanism and determination of the tire forces/moments. A static circular beam model is introduced for the contact mechanism, in which a tire is modeled with three compliance components--6-DOF spring/damper elements for the sidewall and the …

    arizona-thes Repository record for A comprehensive analytical model for pneumatic tires (opens in a new tab)

Page 1 of 5