Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"CdTe detector"”.

  1. Towards simultaneous single emission microscopy and magnetic resonance imaging

    … This system is constructed with 40 small pixel CdTe detector modules assembled in a fully stationary ring SPECT geometry. Series of experiments have demonstrated that this system is capable of providing an imaging resolution of <500μm, when operated inside MR scanners. The ultrahigh resolution …

    uiuc Repository record for Towards simultaneous single emission microscopy and magnetic resonance imaging (opens in a new tab)

  2. Development of an MR-compatible SPECT system based on energy resolved photon counting detectors

    … on novel energy-resolved photon counting (ERPC) detectors we have recently developed for gamma ray imaging applications. The ERPC detector has basic modular configuration that offers an overall detection area of 4.5 cm×4.5 cm, comprising of eight CdTe/CMOS detector hybrids. Each hybrid has a CdTe

    uiuc Repository record for Development of an MR-compatible SPECT system based on energy resolved photon counting detectors (opens in a new tab)

  3. Evaluation of room-temperature semiconductor detectors for ultrahigh resolution pet imaging

    … evaluation of a room-temperature semiconductor detector for ultrahigh resolution positron emission tomography (PET) imaging is presented. The approach is based on the use of a CdTe semiconductor detector. The detector is a 2mm thick cadmium telluride (CdTe) detector with a pixel pitch of 350μm x …

    uiuc Repository record for Evaluation of room-temperature semiconductor detectors for ultrahigh resolution pet imaging (opens in a new tab)

  4. Fisher Information in X-ray/Gamma-ray Imaging Instrumentation Design

    … in a photon-counting x-ray/gamma-ray imaging detector is a complex process resulting in detector signals governed by multiple random effects. Recovering maximum possible information about event attributes of interest requires a systematic collection of calibration data and analysis provided by …

    arizona-thes Repository record for Fisher Information in X-ray/Gamma-ray Imaging Instrumentation Design (opens in a new tab)

  5. Hard X-ray diagnostics of particle acceleration and energy release in solar flares and coronal jets

    … of double- sided cadmium telluride (CdTe) strip detectors, as well as the simulation work that helped to optimize the instrument design for flare observations. FOXSI-4 participated in NASA’s inaugural solar flare campaign along with the Hi- C Flare rocket. By adopting a triggered …

    umn Repository record for Hard X-ray diagnostics of particle acceleration and energy release in solar flares and coronal jets (opens in a new tab)