Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 67 for “"Calibration Methods"”.

  1. Micron precision calibration methods for alignment sensors in particle accelerators

    … fields and cannot be returned for check and calibration to the manufacturer once exposed to radiation. In order to validate the sensors before their installation in the tunnel, to check them within their measurement system and for check and calibration after use, a series of tests have been …

    nott-trent Repository record for Micron precision calibration methods for alignment sensors in particle accelerators (opens in a new tab)

  2. Calibrating the Hurst Parameter for Rough Volatility Models with Application in the South African Market

    It is known that accurate and efficient calibration of any fractional stochastic volatility model is important for trading and risk management purposes. Under the rough Heston model proposed by El Euch et al. (2019), the Hurst parameter governs the roughness of the volatility process. This …

    cape-town Repository record for Calibrating the Hurst Parameter for Rough Volatility Models with Application in the South African Market (opens in a new tab)

  3. METHOD DEVELOPMENT OF STANDARD DILUTION ANALYSIS ON MOLECULES AND DISSOLUTION STUDIES OF IBUPROFEN TABLETS ALONG WITH COMMON BEVERAGE CONSTITUENTS

    … rate of ibuprofen. Results using the external calibration method produced a dissolution rate of ibuprofen that decreased 4% in the presence of ascorbic acid and increased 1% in the presence of caffeine. Figures of merit using current calibration methods such as external calibration method, …

    kennesaw Repository record for METHOD DEVELOPMENT OF STANDARD DILUTION ANALYSIS ON MOLECULES AND DISSOLUTION STUDIES OF IBUPROFEN TABLETS ALONG WITH COMMON BEVERAGE CONSTITUENTS (opens in a new tab)

  4. Using magneto-inertial-measurement-units to track upper-limb movement during rehabilitation

    … coordinate frame. Therefore, appropriate calibration must be performed to obtain the relationship between each sensor frame and its corresponding body-segment anatomical frame.While many papers have been published on anatomical calibration methods for MIMUs, there has been no comprehensive …

    salford Repository record for Using magneto-inertial-measurement-units to track upper-limb movement during rehabilitation (opens in a new tab)

  5. Hardware and software architecture for non-contact, non-intrusive load monitoring

    … fields surrounding a multi-conductor cable, calibration methods to noninvasively determine a mapping from the sensed fields to power transmission, and a software framework that enables efficient real-time processing of data gathered by the new electromagnetic field sensors.

    mit Repository record for Hardware and software architecture for non-contact, non-intrusive load monitoring (opens in a new tab)

  6. Sampled ancestors and dating in Bayesian phylogenetics

    … is not negligible among fossil taxa and the methods that use fossils to date phylogenies should account for this. In this thesis, I develop a Bayesian Markov chain Monte Carlo framework for inferring sampled ancestor phylogenies, investigate properties of the sampled ancestor tree space, test …

    auckland-ms Repository record for Sampled ancestors and dating in Bayesian phylogenetics (opens in a new tab)

  7. MULTIVARIATE CALIBRATION FOR ICP-AES

    … the application of univariate and multivariate calibration methods for the prediction of Pt, Pd, and Rh in acid-digested and of Au, Ag and Pd in fusion-digested autocatalyst samples. Of all the univariate calibration methods investigated matrix matching proved the most accurate method with …

    plymouth Repository record for MULTIVARIATE CALIBRATION FOR ICP-AES (opens in a new tab)

  8. Weigh-in-Motion Auto-Calibration Using Automatic Vehicle Identification

    … accurate data. After initial installation and calibration, WIM systems may experience measurement drifts in weight and axle detection. Recalibration takes two general forms: (a) On-site calibration involving running trucks of known weight over WIM scales and (b) Auto-calibration methods

    arkansas Repository record for Weigh-in-Motion Auto-Calibration Using Automatic Vehicle Identification (opens in a new tab)

  9. Analysis of equity and interest rate returns in South Africa under the context of jump diffusion processes

    … be calibrated. This dissertation tackles this calibration issue by considering the basic jump diffusion model of Merton (197G) applied to South African equity and interest rate market data. As there is little access to frequently updated volatility surfaces and option price data in South …

    cape-town Repository record for Analysis of equity and interest rate returns in South Africa under the context of jump diffusion processes (opens in a new tab)

  10. Design of an ultraviolet absorption spectroscopy oil concentration sensor for online HVAC measurements

    … hardware, the analytical modeling, and the calibration methods to build and operate the OCR sensor.

    mit Repository record for Design of an ultraviolet absorption spectroscopy oil concentration sensor for online HVAC measurements (opens in a new tab)

  11. An Iterative Technique for Instrument Transformer Calibration and Line Parameter Estimation with Synchrophasor Measurements

    … thesis, the questions of instrument transformer calibration and transmission line parameter estimation have been examined. With synchrophasors offering real-time data for analysis, a solution to each individual problem seems feasible. A quandary however arises due to the fact that calibration

    vt Repository record for An Iterative Technique for Instrument Transformer Calibration and Line Parameter Estimation with Synchrophasor Measurements (opens in a new tab)

  12. Sequential Calibration of Asset Pricing Models to Option Prices

    This paper implements four calibration methods on stochastic volatility models. We estimate the latent state and parameters of the models using three non-linear filtering methods, namely the extended Kalman filter (EKF), iterated extended Kalman filter (IEKF) and the unscented Kalman filter (UKF). …

    cape-town Repository record for Sequential Calibration of Asset Pricing Models to Option Prices (opens in a new tab)

  13. Sequential learning, large-scale calibration, and uncertainty quantification

    … methodologies in sequential learning, model calibration, and uncertainty quantification for heteroskedastic computer experiments and large-scale computer experiments. For heteroskedastic computer experiments, an optimal lookahead based sequential learning strategy is presented, balancing …

    vt Repository record for Sequential learning, large-scale calibration, and uncertainty quantification (opens in a new tab)

  14. Person tracking in 3D using Kalman filtering in single and multiple camera environments

    … coordinate system. We investigate some practical methods of obtaining this calibration information without laying out and measuring calibration markers. Both tracking and calibration methods were tested extensively using 6 different single and multiple camera test sequences. The system is able to …

    cape-town Repository record for Person tracking in 3D using Kalman filtering in single and multiple camera environments (opens in a new tab)

  15. Online Raman spectroscopy for bioprocess monitoring

    … repeatability and throughput for offline and calibration methods was developed accordingly. The theoretical and experimental ground work for developing a correction for spectrum distortions caused by elastic scattering, a fundamental problem for many spectroscopic applications, was laid out. …

    mit Repository record for Online Raman spectroscopy for bioprocess monitoring (opens in a new tab)

  16. Gene transfer history of carbon fixation proteins constrains marine cyanobacteria divergence times

    … integrates gene transfer with molecular clock calibration methods to determine divergence times. Accordingly, I evaluate the relationship between atmospheric evolution and the ecology of important groups of phototrophs.

    mit Repository record for Gene transfer history of carbon fixation proteins constrains marine cyanobacteria divergence times (opens in a new tab)

  17. Monte Carlo simulations for the purpose of efficiency curve calibration for the Fastscan whole body counter

    … counter must be calibrated correctly. Current calibration methods do not take the full range of body types into consideration when creating efficiency curve calibrations. The goal of this work is the creation of a Monte Carlo (MCNP) model, that allows the simulation of efficiency curves for a …

    uoit Repository record for Monte Carlo simulations for the purpose of efficiency curve calibration for the Fastscan whole body counter (opens in a new tab)

  18. An On-orbit Calibration Procedure for Spaceborne Microwave Radiometers Using Special Spacecraft Attitude Maneuvers

    … dissertation revisits, develops, and documents methods that can be used to calibrate spaceborne microwave radiometers once in orbit. The on-orbit calibration methods discussed within this dissertation can provide accurate and early results by utilizing Calibration Attitude Maneuvers (CAM), which …

    ucf

Page 1 of 4