Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"Blutpumpe"”.

  1. Implantierbares elektromechanisches Blutpumpensystem zur langfristigen partiellen Herzentlastung

    Nowadays, Ventricular Assist Devices (VADs) have mostly been employed as bridge to transplantation. A new field of application for VADs represents the support of the failing heart function with the aim of heart recovery, "bridge to recovery". This dissertation describes the development of a …

    aachen Repository record for Implantierbares elektromechanisches Blutpumpensystem zur langfristigen partiellen Herzentlastung (opens in a new tab)

  2. Numerische Simulation der Strömung in Miniaturkreiselpumpen zur Blutförderung

    New operation techniques on patients undergoing cardiovascular surgery or short-term ventricular assistance have lead to the development of a new generation of blood pumps with minimal size. This development is mainly focussed on hydraulic performance and biocompatibility. This thesis covers the …

    aachen Repository record for Numerische Simulation der Strömung in Miniaturkreiselpumpen zur Blutförderung (opens in a new tab)

  3. In-vivo-Implantation der Mikrodiagonalpumpe II beim Kalb : Hämodynamik und Hämolyse

    Due to the increasing number of patients suffering from end-stage heart failure and the decreasing number of heart transplants the search for alternative treatment strategies is intensified. Artificial blood pumps may be used to bridge patients to transplant or might even be implanted as …

    aachen Repository record for In-vivo-Implantation der Mikrodiagonalpumpe II beim Kalb : Hämodynamik und Hämolyse (opens in a new tab)

  4. Tierexperimentelle Untersuchungen zu Praktikabilität und Hämokompatibilität einer miniaturisierten extrakorporalen Membranoxygenierung

    During treatment on an intensive care unit a severe complication of shock, sepsis or pneumonia is the development of ARDS (acute respiratory distress syndrome). An aggressive ventilation strategy is necessary to prevent hypoxemia but causes further damage to the lungs. The ventilator-induced lung …

    aachen Repository record for Tierexperimentelle Untersuchungen zu Praktikabilität und Hämokompatibilität einer miniaturisierten extrakorporalen Membranoxygenierung (opens in a new tab)

  5. Evaluation eines Hemoresistometers

    The development of blood pumps for use in heart surgery has to fulfill different demands. On the one hand there is technical performance, on the other hand there is low rate of complications. The technical performance can be tested without difficulty by in-vitro tests. Estimation of mean …

    aachen Repository record for Evaluation eines Hemoresistometers (opens in a new tab)

  6. Einfluss von hyperthermen Oberflächen auf Humanblut

    In order to estimate the impact of exposure of human blood to elevated surface temperatures in blood-conducting systems, detailed data is required. Therefore, titanium alloy housing dummies were immersed in 25 ml heparinized human blood. The dummies were constantly tempered at specific temperatures …

    aachen Repository record for Einfluss von hyperthermen Oberflächen auf Humanblut (opens in a new tab)

  7. Implantable electromechanical displacement blood pumps : systematic design and validation methods

    Blood pumps are developed for different clinical indications, such as cardiopulmonary bypass, extracorporeal membrane oxygenation, ventricular assist (bridge to recovery, bridge to transplant, destination therapy) or heart replacement. The REMATCH trial has demonstrated that mechanical circulatory …

    aachen Repository record for Implantable electromechanical displacement blood pumps : systematic design and validation methods (opens in a new tab)

  8. Die Mikrodiagonalpumpe : tierexperimentelle Untersuchung eines Linksherzunterstützungssystems unter besonderer Berücksichtigung des Thromboembolie-Risikos

    Due to the discrepancy between the number of available donor organs and patients waiting for heart transplantation after suffering from end stage heart failure, intensive research has been undertaken to find alternatives to bridge time to transplantation or as live saving therapy. Over the last …

    aachen Repository record for Die Mikrodiagonalpumpe : tierexperimentelle Untersuchung eines Linksherzunterstützungssystems unter besonderer Berücksichtigung des Thromboembolie-Risikos (opens in a new tab)

  9. Numerical simulation of platelet adhesion, activation and aggregation : application to Taylor-Couette systems

    Heart attack and stroke are among the leading causes of death in industrial nations but the number of candidates needing a transplant exceeds the number of transplants performed. Due to this chronic shortage, blood pumps are needed to deliver appropriate hydraulic performance while maintaining …

    aachen Repository record for Numerical simulation of platelet adhesion, activation and aggregation : application to Taylor-Couette systems (opens in a new tab)

  10. Kenngrößenorientierte Beurteilung von Rotationsblutpumpen diagonaler Bauart mittels numerischer Strömungssimulation

    The aim of this work was to analyse the flow phenomena within the implantable rotary blood pump “MikroDiagonalPump” (MDP) by means of Computational Fluid Dynamics (CFD). In the first part, a method has been developed to evaluate different pump geometries and impeller variations in a standardised …

    aachen Repository record for Kenngrößenorientierte Beurteilung von Rotationsblutpumpen diagonaler Bauart mittels numerischer Strömungssimulation (opens in a new tab)