Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 25 for “"Bioelectrical impedance analysis"”.
-
The use of bioelectrical impedance analysis for estimating the body composition of various fish species
… estimate body composition is lacking. Proximate analysis is the most dependable and accurate method for estimating internal composition, but it is lethal, time consuming, and expensive. Recent research has shown bioelectrical impedance analysis (BIA) to be an effective method for estimating …
-
Use of bioelectrical impedance analysis (BIA) to predict water and energy content of juvenile Rainbow Trout (Oncorhynchus mykiss)
… of fish. Bomb calorimetry and proximate analysis are currently the most dependable and accurate methods to estimate energy content and body composition. However, bioenergetic studies that employ the traditional methodology necessitate the killing of fish to determine physiological …
-
Bioelectrical impedance analysis as a predictor of fish health and energy content in juvenile rainbow trout (Oncorhynchus mykiss)
… using bomb calorimetry or proximate composition analysis; however, both of these methods necessitate sacrificing the fish in order to obtain accurate data. This has led to research into novel non-lethal methods of analyzing fish tissue so as to determine the body composition and health condition …
-
Body Composition Assessment After Pediatric Liver Transplant
… and to determine whether multiple-frequency bioelectrical impedance analysis and ultrasound will accurately describe body composition and quality of weight gain. Methods Ten children (n=10) with a median age of 9.5 years were recruited from the liver transplant program at the University of …
-
Omega-3 fatty acid supplementation to improve body composition and perceived stress in collegiate athletes.
… oil. Baseline and post-study measures included Bioelectrical Impedance Analysis (BIA), Omega-3 Index, and Perceived Stress Score (PSS). Results: No statistically significant changes were observed in either group after 8 weeks. Conclusions: FO n-3 supplementation did not significantly impact body …
-
Potential for osteoporosis in selected dancers
… blood sample, the Eating Disorder Inventory, the Bioelectrical Impedance Analysis machine, an activity level/menstrual status questionnaire, a three day diet record, and a demographic data form. The subjects were similar in age, age at menarche, and menstrual periods per year. The major …
-
The influence of silvicultural manipulations on plethodontid salamanders
… for plethodontid salamanders. I found that bioelectrical impedance analysis (BIA) is likely not suitable for use with plethodontid salamanders and mass divided by snout-to-vent-length is likely a superior estimate to tail width divided by snout-to-vent-length. These findings further our …
-
Statistical modelling of body composition in children and their parents
… novel methods of determining body composition, bioelectrical impedance analysis (BIA) and bony frame, in addition to anthropometry (body mass index in particular) and skinfolds. Parental body composition is thought to be influential on their children's body composition. Such influence does not …
-
A Reliability and Criterion-Related Validity Study of Bioelectric Impedance Analysis (BIA)
… reliability and criterion-related validity of bioelectrical impedance analysis (BIA) as a method of monitoring fluid changes in congestive heart failure (CHF) patients undergoing diuresis. Procedure. Thirty hospitalized CHF patients undergoing diuresis were measured with BIA and weighed prior …
-
Childhood obesity treatment: integrating mobile health technology into a paediatric obesity service
… In Study 3, body composition was estimated with bioelectrical impedance analysis (BIA) and dual x-ray absorptiometry (DXA) and linear regression analyses were used to estimate the extent to which each methods predicted change in IS. Study 4 describes the development of the Temple Street W82GO …
-
Changes in Body Mass, Body Composition, Physical Activity and Nutrition from the First to the Fourth Academic Year in University Students
… measured and body composition assessed using bioelectrical impedance analysis. These measurements were obtained at the beginning (fall) and end (spring) of 1st year and the end (spring) of 4th year. Results: During the 1st year, body mass and percent fat increased by 3.2 kg and 2.1%, …
-
Validity of Bioimpedance as a Measure of Body Fat in High School Wrestlers
… and reliability. Of those devices leg-to-leg bioelectrical impedance analysis (BIA) has been suggested for use with wrestlers. Purpose: To test the validity of bioelectrical impedance as an instrument of body composition and minimum wrestling weight compared to three-site skinfold using the …
-
Reliability and Validity of Body Composition and Bone Mineral Density Measurements by DXA
… was assessed from comparison to single-frequency bioelectrical impedance analysis (BIA). Significant differences were not found in measures of %BF by DXA and BIA. A second study investigated the reliability and validity of the QDR-4500A DXA in measurements of distal tibia (DT) BMD. Significant …
-
Predicting Cardiovascular Fitness in Ethnic Minority Youth: A Comparison of Demographic, Body Composition, and Physical Activity Variables
… composition (Body Mass Index [BMI] percentile, Bioelectrical Impedance Analysis [BIA]-measured body fat percentage), and habitual physical activity (accelerometer-measured counts per minute). These factors were entered in a hierarchical regression model to predict cardiorespiratory fitness …
-
The influence of ethnicity, socioeconomic status and obesity intervention on body composition in UK children and adolescents
… more objective measures of body fatness such as Bioelectrical Impedance Analysis (BIA) and more sensitive measures of body fat distribution such as waist circumference be introduced as alternative methods or adjuncts to BMI The third study examined ethnicity-related variation in whole body and …
-
Measuring Nutritional Status, Hydration and Body Composition Changes in Acute Stroke
… after stroke assessed using multi-frequency bioelectrical impedance analysis (MF-BIA) methods, examine the utility of MF-BIA in diagnosing dehydration in stroke patients, and validate MF-BIA selected body composition estimates against the reference method Dual X-ray absorptiometry (DEXA). …
-
The impact of post operative oedema on clinical recovery and its potential causes
… of oedema was related to changes whole-body impedance (Z), obtained at four frequencies (5, 50, 100 and 200 kilohertz (kHz)) using bioelectrical impedance analysis (BIA) and to clinical outcomes. The fluid intake and output and changes in plasma concentration of albumin, total protein, …
-
Improved characterisation of measures of fatness and metabolic risks in older adolescents and young adults in the South Asian population in the UK
… SA background living in the UK. Single-frequency bioelectrical impedance analysis technology was used for assessment of body composition. Body composition and anthropometric data were used to construct the gender and ethnic specific centile curves using the LMS method for all variables. Comparison …
-
Secretory immunity in overweight and obese versus normal-weight early-and late-pubertal females
… 1900 hours Relative body fat was assessed using bioelectrical impedance analysis. Resting saliva samples were obtained and assayed (ELISA) for testosterone, Cortisol, melatonin and secretory immunoglobulin A. Physical activity was self-reported using the Godin- Shephard Leisure time …
-
Physical activity and breast cancer
… three, body fat percentage was measured via bioelectrical impedance analysis, HRQoL was assessed using the Functional Assessment of Cancer Therapy-Breast (FACT-B) questionnaire and fasting blood samples were taken to measure lipid, glucose and insulin concentrations at baseline and post-six …
Page 1 of 2