Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 11 of 11 for “"Beam monitoring"”.
-
Neutron beam monitoring for single-event effects testing
… in this thesis aims to develop a neutron beam monitoring system using silicon photodiodes as the detecting elements for accelerated testing of electronics against neutron-induced single event effects (SEEs). The system can measure the transmission along the neutron beam line where several …
-
Coherence Control and Measurement at the CLS Using X-ray Interferometry
… and coherence, emerging challenges arise in beam diagnostic tools that accurately monitor and control the spatial degree of coherence. MBA lattice designs in modern fourth generation light sources significantly reduce the transverse beam size, posing challenges for beam monitoring due to …
-
Real-time beam visualization and therapy planning for focused ultrasound therapies using a diagnostic imaging array
… (MRI). Pre-therapy planning and real-time monitoring during treatment are crucial to ensure that healthy tissues are not affected by the FUS beam. To provide a cost-effective method for FUS therapy monitoring, we present a novel technique for real-time visualization of an FUS beam using …
-
A measurement of the anomalous magnetic moment of the positive muon with a precision of 0.7 parts per million
Submitted by Meng Tao (mengtao2@illinois.edu) on 2012-10-12T23:51:29Z No. of bitstreams: 1 Gray.pdf: 7421846 bytes, checksum: 2c59c9dfe8e80ceb462eb0bd73fad03f (MD5)
-
Insights into the radiation Chemistry of FLASH Radiation Therapy
… radiolytic species production and physical beam parameters relevant to FLASH-RT, alongside dosimetry tools for reliable UHDR beam characterization.</p> <p><strong>Methods:</strong> A beam collector (BC) Faraday cup detector was characterized on a FLASH Mobetron and benchmarked against a …
-
Facilitating the Clinical Translation of Flash Radiotherapy Through Dosimetry Development and Beam Parameter Optimization
… discrepancy is due to marked differences in the beam parameter settings that are used but are not often reported which complicates retrospective studies evaluating the FLASH effect. Additionally, limitations in existing dosimetry systems in accurately capturing these beam parameters may also be …
-
Monte Carlo calculation and analysis of neutron and gamma fields at spallation neutron sources for simulating cosmic radiation
… testing of electronic components. A local beam monitoring system was successfully developed by S. Platt and L. Zhang in the University of Central Lancashire for measuring neutron dosimetry during accelerated SEE testing of electronic devices with using silicon photodiode. However, such …