  1. Anesthetic conserving device : Arbeitsplatzbelastung und praktische Umsetzung

    This thesis consists of two parts: In the first part, the goal is to determine the actual degree of gas exposure for personnel in the Intensive Care Unit (ICU) by using the Anesthetic Conserving Device® (AnaConDa®). Therefore, three different test methods were used in the laboratory at the …

    aachen Repository record for Anesthetic conserving device : Arbeitsplatzbelastung und praktische Umsetzung (opens in a new tab)

  2. Vergleich der Arbeitsplatzbelastung während einer Xenon- oder Lachgasanästhesie

    The aim of this study was to compare waste gas concentrations during xenon or nitrous oxide anaesthesia. A total of 64 patients were included in this study. Gas concentrations were measured with a mass spectrometer during anaesthesia. The probes were taken beside the patient's head and thorax and …