Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"Advanced Photon Source (APS)"”.

  1. Stress relaxation of AZ31 alloy using high energy diffraction microscopy

    … relaxation. The study was conducted at the Advanced Photon Source (APS) sector 1-ID-C at Argonne National Laboratory and loading steps and relaxation were set at different points within elasto-plastic transitions (118MPa, 135MPa, 153MPa and 168MPa). Two different aspects of diffraction …

    uiuc Repository record for Stress relaxation of AZ31 alloy using high energy diffraction microscopy (opens in a new tab)

  2. X-ray microscope performance enhancement through control architecture change

    … nanopositioning devices used on the beamline in Advanced Photon Source (APS) at Argonne National Laboratory (ANL). A prototype device, better known as the Early User Instrument (EUI) was the subject of this work. It consists of X-ray optics stage group that focuses the X-ray beam as a …

    uiuc Repository record for X-ray microscope performance enhancement through control architecture change (opens in a new tab)

  3. Beam-Induced Radiation Heating on the Superconducting Undulator at the Advanced Photon Source

    <p>In January 2013 the Advanced Photon Source (APS), a 7 GeV synchrotron X-ray source, commissioned a Superconducting Undulator (SCU). The superconducting magnet is thermally isolated from the beam vacuum chamber, which absorbs the beam-induced heating. Previous beam induced heat load studies at …

    purdue-thes Repository record for Beam-Induced Radiation Heating on the Superconducting Undulator at the Advanced Photon Source (opens in a new tab)

  4. Thermal expansion behavior of Mo-Si-B system intermetallics

    … using synchrotron radiation is done at Advanced Photon Source (APS) of Argonne National Laboratory and Cornell High Energy Synchrotron Source (CHESS) of Cornell University. The Rietveld refinement of diffraction pattern is performed through using General Structure Analysis System (GSAS) …

    iastate Repository record for Thermal expansion behavior of Mo-Si-B system intermetallics (opens in a new tab)

  5. Optical instruments for characterization in the nano-scale

    … accuracy can be built with such lasers as light sources. This thesis two such instruments, the Florescence Correlation Spectroscope for determination of hydrodynamic size of quantum dot bioprobes to nanometer precision in part one, and the Long Trace Profiler/Optical Slope Measurement System for …

    uiuc Repository record for Optical instruments for characterization in the nano-scale (opens in a new tab)

  6. Development of novel emission tomography system

    … monitoring. Based on tracer principle single photon emission computed tomography (SPECT) has increased popularity in small animal imaging due to its higher spatial resolution and variety of single-photon emitting radionuclide. Since the image quality strongly depends on the detector …

    uiuc Repository record for Development of novel emission tomography system (opens in a new tab)

  7. High-bandwidth high-precision robust x-ray microscopy - a control systems approach

    … stages of Velociprobe X-ray microscope at Advanced Photon Source (APS) at Argonne National Laboratory (ANL) is presented. In particular, our focus is on maintaining a precise position of the optics scanning stages in the XY lateral plane relative to the sample stages, which will ensure that …

    uiuc Repository record for High-bandwidth high-precision robust x-ray microscopy - a control systems approach (opens in a new tab)

  8. In situ measurement of lattice strain using synchrotron radiation and a conical slit system

    … slit system at Argonne National Laboratory’s Advanced Photon Source is utilized to isolate a single grain with an orientation of interest from the highly textured alloy. A total of 39 reflections contribute to the calculation of the strain tensor for each load step. Trends were realized in all …

    uiuc Repository record for In situ measurement of lattice strain using synchrotron radiation and a conical slit system (opens in a new tab)