  1. IMAGE-BASED RESPIRATORY MOTION EXTRACTION AND RESPIRATION-CORRELATED CONE BEAM CT (4D-CBCT) RECONSTRUCTION

    … Respiration-correlated or four-dimensional CT (4DCT) imaging techniques have been recently integrated into imaging systems for verifying tumor position during treatment and managing respiration-induced tissue motion. The quality of the 4D reconstructed volumes is highly affected by the …

    vcu Repository record for IMAGE-BASED RESPIRATORY MOTION EXTRACTION AND RESPIRATION-CORRELATED CONE BEAM CT (4D-CBCT) RECONSTRUCTION (opens in a new tab)

  2. Motion Estimation and Motion-Compensated Reconstruction for Four-Dimensional Cone Beam Computed Tomography (4D-CBCT)

    … localization uncertainty and four dimensional (4D) cone beam computed tomography (CBCT) has been developed to locate tumor in each respiration phase to better estimate the possible motion range of the tumor motion during the treatment. However, 4D-CBCT reconstructed by conventional methods on …

    utswmed Repository record for Motion Estimation and Motion-Compensated Reconstruction for Four-Dimensional Cone Beam Computed Tomography (4D-CBCT) (opens in a new tab)

  3. Design and Optimization of Four-Dimensional Cone-Beam Computed to mography In Image-Guided Radiation Therapy

    … four-dimensional cone-beam computed tomography (4D-CBCT), which acquires an image set of the dynamic target throughout the respiratory cycle during the therapy session. 4D-CBCT is undersampled if the scan time is too short. However, short scan time is desirable in clinical practice to reduce …

    uthsc Repository record for Design and Optimization of Four-Dimensional Cone-Beam Computed to mography In Image-Guided Radiation Therapy (opens in a new tab)

  4. Four-Dimensional Imaging of Respiratory Motion in the Radiotherapy Treatment Room Using a Gantry Mounted Flat Panel Imaging Device

    … Four-dimensional cone-beam computed tomography (4D CBCT) using a gantry mounted 2D flat panel imaging device has been proposed but has been limited by high doses, long scan times and severe under-sampling artifacts. The focus of the work completed in this thesis was to find ways to improve 4D

    duke Repository record for Four-Dimensional Imaging of Respiratory Motion in the Radiotherapy Treatment Room Using a Gantry Mounted Flat Panel Imaging Device (opens in a new tab)

  5. Improvements In Four-Dimensional and Dual Energy Computed to mography

    <p>Dual energy and 4D computed tomography (CT) seek to address some of the limitations in traditional CT imaging. Dual energy CT, among other purposes, allows for the quantification and improved visualization of contrast materials, and 4D CT is often used in radiation therapy applications as it …

    uthsc Repository record for Improvements In Four-Dimensional and Dual Energy Computed to mography (opens in a new tab)

  6. Optimization of Image Guided Radiation Therapy for Lung Cancer Using Limited-angle Projections

    … as the 3D-DTS technique, but uses the planning 4D computed tomography (CT) to synthesize a phase-matched reference DTS to register with the on-board DTS for tumor localization. Of the 324 different scenarios simulated using the extended cardiac torso (XCAT) digital phantom, the phase-matched DTS …

    duke Repository record for Optimization of Image Guided Radiation Therapy for Lung Cancer Using Limited-angle Projections (opens in a new tab)