Motion binning in cone-beam CT without a prior Model

Abstract

dc:description.abstract

Cone-beam CT (CBCT), used to reduce setup error in radiotherapy, takes a sequence of about 670 two-dimensional X-rays acquired in a circular arc around the patient over two minutes and reconstructs a three-dimensional volume from these projections. Consequently, when tissues move significantly during the acquisition the resulting volume is blurry or contains streaks. The projections themselves, though, are sharp. One of the main areas of research with CBCT has been to attempt to reconstruct the motion from these projections by collecting them into respiratory-phase or amplitude bins and using these to reconstruct bin-specific volumes. A variety of mechanisms are employed to identify and record respiratory motion so that it can be correlated with the projections. Not all motion that occurs in the body can be correlated with respiration. The research question pursued in this thesis is whether motion can be identified in a binning process without prior knowledge or models of the motion. Nomenclature describing motion classes and a specific type of artefact are introduced. The distinctiveness of this artefact class is demonstrated and methods to mitigate it are proposed and evaluated. Several techniques are then used to reduce an intractable search space to a computationally feasible one. A unique application of PCA to the reconstruction process allows new kinds of search approaches to be considered including an exhaustive search which requires a protocol change and a multiple-restart hill-climbing search that can be used with existing protocols. Experiments with three classes of phantoms, including a novel animated physical phantom, show the effectiveness of the two search methods which are finally compared with each other.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Leeds
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Petrie, Tracy
Advisor dc:contributor.advisor
  • Magee, D.

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.536095
OAI identifier oai:identifier
oai:etheses.whiterose.ac.uk:1684

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Petrie, Tracy. Motion binning in cone-beam CT without a prior Model. doctoral thesis, University of Leeds, 2010.