Back to search

Virginia Tech

Mechanical Design of the Legs for OLL-E, a Fully Self-Balancing, Lower-Body Exoskeleton

Abstract

dc:description.abstract

Exoskeletons show great promise in aiding people in a wide range of applications. One such application is medical rehabilitation and assistance of those with spinal cord injuries. Exoskeletons have the potential to offer several benefits over wheelchairs, including a reduction in the risk of upper-body injuries associated with extended wheelchair use. To fully mitigate this risk of injury, exoskeletons will need to be fully self-balancing, able to move and stand without crutches or other walking aid. To accomplish this, the Orthotic Lower-body Locomotion Exoskeleton (OLL-E) will actuate 12 Degrees of Freedom, six in each leg, using custom design linear series elastic actuators. The placement of these actuators relative to each joint axis, and the geometry of the linkage connecting them, were critical to ensuring each joint was capable of producing the required outputs for self-balancing locomotion. In pursuit of this goal, a general model was developed, relating the actuator's position and linkage geometry to the actual joint output over its range of motion. This model was then adapted for each joint in the legs and compared against the required outputs for humans and robots moving through a variety of gaits. This process allowed for the best placement of the actuator and linkages within the design constraints of the exoskeleton. The structure of the exoskeleton was then designed to maintain the desired geometry while meeting several other design requirements such as weight, adjustability, and range of motion. Adjustability was a key factor for ensuring the comfortable use of the exoskeleton and to minimize risk of injury by aligning the exoskeleton joint axes as close as possible to the wearer's joints. The legs of OLL-E can accommodate users between 1.60 m and 2.03 m in height while locating the exoskeleton joint axes within 2 mm of the user's joints. After detailed design was completed, analysis showed that the legs met all long-term goals of the exoskeleton project.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wilson, Bradford Asin
Chair dc:contributor.committeechair
  • Asbeck, Alan T.
Committee members dc:contributor.committeemember
  • Leonessa, Alexander
  • Southward, Steve C.

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:22073
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/93574

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Wilson, Bradford Asin. Mechanical Design of the Legs for OLL-E, a Fully Self-Balancing, Lower-Body Exoskeleton. masters thesis, Virginia Tech, 2019. http://hdl.handle.net/10919/93574