Back to search

Virginia Tech

Effect of Postmortem Time and Preservation Fluid on the Tensile Material Properties of Bovine Liver Parenchyma

Abstract

dc:description.abstract

The liver is one of the most frequently injured abdominal organs in motor vehicle collisions. Although previous studies have quantified the tensile failure properties of human liver parenchyma at 48hrs postmortem, it is currently unknown how the material properties change between time of death and 48hrs postmortem. Therefore, the purpose of this study was to quantify the effects of postmortem degradation on the tensile material properties of bovine liver parenchyma when stored in DMEM or saline. Fourteen fresh bovine livers were obtained from a local slaughter house and stored in either DMEM or saline as large blocks, small blocks, or slices of tissue. Multiple parenchyma dog-bone samples from each liver were tested once to failure at three time points: ~6hrs, ~24hrs, and ~48hrs postmortem. The data were then analyzed to determine if there were significant changes in the material properties with respect to postmortem time. The results showed that the failure strain decreased significantly between 6hrs and 48hrs after death when stored as large blocks in saline. Conversely, neither the failure stress nor failure strain changed significantly with respect to postmortem time when stored as large blocks in DMEM. The modulus did not significantly change for tissue stored as large blocks in either fluid. Preliminary results indicated that reducing the tissue storage size had a negative effect on the material properties and cellular architecture. Overall, this study illustrated that the effects of postmortem liver degradation varied with respect to the preservation fluid, storage time, and storage block size.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering
Department dc:contributor.department
Department of Biomedical Engineering and Mechanics
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dunford, Kristin Marie
Chair dc:contributor.committeechair
  • Kemper, Andrew R.
Committee members dc:contributor.committeemember
  • Duma, Stefan M.
  • Hardy, Warren N.

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:13279
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/90179

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Dunford, Kristin Marie. Effect of Postmortem Time and Preservation Fluid on the Tensile Material Properties of Bovine Liver Parenchyma. masters thesis, Virginia Tech, 2017. http://hdl.handle.net/10919/90179