Back to search

Virginia Tech

Realization of a Measuring Device for Recordning the Relative Movement between Residual Limb and Prosthetic Socket

Abstract

dc:description.abstract

Relative motion between residual limb and prosthetic socket is an indication of poor fit. Both the fabrication and fitting processes are highly subjective and a favorable result depends upon the technician's expertise. Although numerous methods exist to measure the relative motion, all have limitations and are not well suited for clinical use. A measurement system using optical sensors has been proposed by students at the Technische Universität Darmstadt and evaluations of a functional model have yielded promising results. In this thesis, the existing functional model is improved and expanded to use an array of sensors. A new microcontroller is selected and incorporated into the system. The software and data communication are optimized for fast, reliable performance and the system is then evaluated on a test rig to determine favorable calibration settings and quantify performance. System frequencies up to 1299 Hz are achieved. It is found that the surface microstructure has a dominant effect over short measurement distances; calibrations performed over longer distances are to be preferred. For the chosen calibration factors, the greatest relative errors over a 40 mm distance are found to be 0.90% ± 0.51% in the X direction and -4.76% ± 1.61% in the Y-direction. A systematic drift is also identified. The final system accommodates up to eight sensors and is controlled from a feature-rich MATLAB GUI.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Whitmore, Sigrid Ilona
Chairs dc:contributor.committeechair
  • Asbeck, Alan T.
  • Rinderknecht, Stephan
Committee members dc:contributor.committeemember
  • Hardt, Steffen
  • Bohn, Jan Helge

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:16593
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/84478

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Whitmore, Sigrid Ilona. Realization of a Measuring Device for Recordning the Relative Movement between Residual Limb and Prosthetic Socket. masters thesis, Virginia Tech, 2018. http://hdl.handle.net/10919/84478