Back to search

Virginia Polytechnic Institute and State University

The determination of HETP and column efficiency for an annular preparative-scale gas-liquid chromatographic column

Abstract

dc:description.abstract

The purpose of this investigation was to design, build, and test a preparative-scale column which contained a blocked-off center tube, thus forming an annular space for the packing. The chromatographic system for this study consisted of 1-methylnaphthalene injections with helium carrier gas and a liquid phase of Craig polyester succinate on crushed firebrick. The analytical column had an inside diameter of 0.061 inches. For the preparative-scale column, the outer diameter was. 2.075 inches and the inside diameter was 1.050 inches. The operating temperature for both columns was 300 degrees Fahrenheit. The flow rates were 0.012 and 10.30 liters per minute for the analytical and preparative-scale columns, respectively. Several sample sizes were injected on both columns. Variation of HETP with sample size was determined. Preparative-scale column efficiencies were calculated from average HETP's at all sample sizes tested. Efficiencies of 36.5, 33.4, 58.2, 69.3, and 52.7 per cent relative to the analytical column were calculated for preparative-scale injections of 0.1, 0.3, 0.5, 0.7, and 0.9, milliliters, respectively. HETP for the preparative-scale column was very sensitive to variation in sample size in the range from 0.l to 0.9 milliliters. HETP for the analytical column was not sensitive to variation in sample size in the range from 0.12 to l.00 microliters, as was expected from literature data.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Chemical Engineering
Department dc:contributor.department
Chemical Engineering
Grantor dc:publisher
Virginia Polytechnic Institute and State University
Year dc:date.issued
1970

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Leonard, Donald Ray

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10919/71029
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/71029

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Leonard, Donald Ray. The determination of HETP and column efficiency for an annular preparative-scale gas-liquid chromatographic column. masters thesis, Virginia Polytechnic Institute and State University, 1970. http://hdl.handle.net/10919/71029