Back to search

Virginia Polytechnic Institute

Waste stabilization ponds: Possible contamination of the shore

Abstract

dc:description.abstract

A waste stabilization pond was investigated to determine if there was a health hazard due to contamination of the shore line. Soil samples were taken at various points along the bank and water samples were collected from the pond. Coliform and enterococci counts were made from the samples and were employed in conjunction with observations made of conditions at the sample points to determine if a health hazard existed at the shore line. Three stations were located along the leeward side of the pond. At each station samples were taken in adjacent soil, soil at the water line, water at the water line, water from the pond surface and water from one and one-half feet beneath the pond surface off shore. Using the geometric mean, coliform counts ranked as follows: 1717.7 water sample one and one-half feet below the surface and off shore, 583.9 soil sample at the water line, 79.0 soil on adjacent bank, 20.2 surface water sample off shore, and 11.5 water sample at water line. The high count one and one-half feet below the surface is presumably from the sewage being added to the pond. Low counts were associated with pH values near ten. High counts generally occurred at more neutral pH values of about eight. The counts at the water line are not high enough to indicate the presence of significant concentrations of fecal matter. Also, no fecal matter or other floating matter was observed at the shore line. The counts from the soil on the bank up from the shore line were what would be expected from a similar area excluding the waste stabilization pond. A comparison of the coliform and enterococci counts showed that the enterococci count is approximately one half the coliform count which is in agreement with other investigations (2) and indicates its usefulness as an indicator organism.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Sanitary Engineering
Department dc:contributor.department
Sanitary Engineering
Grantor dc:publisher
Virginia Polytechnic Institute
Year dc:date.issued
1963

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wentworth, Wesley John

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10919/54884
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/54884

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Wentworth, Wesley John. Waste stabilization ponds: Possible contamination of the shore. masters thesis, Virginia Polytechnic Institute, 1963. http://hdl.handle.net/10919/54884