Back to search

Virginia Tech

Transformer Shielding Technique for Common Mode Noise Reduction in Switch Mode Power Supplies

Abstract

dc:description.abstract

Switch mode power supplies are widely used in different applications. High efficiency and high power density are two driving forces for power supply systems. However, high dv/dt and di/dt in switch mode power supplies will cause severe EMI noise issue. In a typical front-end converter, the EMI filter usually occupies 1/3 to 1/4 volume of total converter. Hence, reducing the EMI noise of power converter can help reduce the volume of EMI filter and improving the total power density of the converter. For off-line switch mode power supplies, DM noise is dominated by PFC converter. CM noise is a more complicated issue. It is contributed by both PFC converter and DC/DC converter. While many researches have focused on reducing CM noise for PFC converter, the CM noise of DC/DC converter still remains a challenge. The main objective of this thesis is provide a solution to have best CM noise reduction for DC/DC converters. The shielding concept and balance concept are combined to propose a novel balance double shielding technique. This method can have an effective CM noise reduction in the circuit level. In addition it is easy to design and implement in the real production. The balance condition is easily controlled and guarantees effective CM noise reduction in mass production. Then, a novel one-layer shielding method for PCB winding transformer is provided. This shielding technique can block CM noise from primary side and also cancel the CM noise from secondary side. In addition, shielding does not increase the loss of converter too much. Furthermore, this shielding technique can be applied to matrix transformer structure. For matrix transformer LLC converter, the inter-winding capacitor is very large and will cause severe CM noise problem. By adding shielding layer, CM noise has been greatly reduced. In addition, by modifying the secondary winding, the loss on shielding layer is minimized and experiments show that the total efficiency of converter has almost no impact. Furthermore, although this thesis uses flyback and LLC resonant converter as example to demonstrate the concept, the novel shielding technique can also be applied to other topologies that have similar transformer structure.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Electrical Engineering
Department dc:contributor.department
Electrical and Computer Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yang, Yuchen
Chair dc:contributor.committeechair
  • Lee, Fred C.
Committee members dc:contributor.committeemember
  • Burgos, Rolando
  • Li, Qiang

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:3093
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/49263

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Yang, Yuchen. Transformer Shielding Technique for Common Mode Noise Reduction in Switch Mode Power Supplies. masters thesis, Virginia Tech, 2014. http://hdl.handle.net/10919/49263