Back to search

Virginia Tech

Determination of the service life of concrete sealers on horizontal and vertical bridge members

Abstract

dc:description.abstract

Due to the increasing rate of deterioration of concrete bridges caused by exposure to chlorides, it has become apparent that effective protection methods need to be employed which will prevent chlorides from reaching critical contamination within the life of the structure. One method of protection is the application of concrete surface sealers which form water-resistant barriers and reduce chloride intrusion. It is imperative to know how effective sealers are and how long sealers retain their effectiveness in order to plan reapplication and estimate life cycle costs for comparison to other maintenance activities. This research was conducted to predict the service life of concrete sealers for both horizontal and vertical bridge components. As a secondary goal, the use of a rapid, non-destructive Surface Absorption Test (SAT) was investigated as a possible substitute for analyzing the condition of sealers. This was done by comparing SAT results with the standard concrete sampling and chloride analysis technique typically employed. Four sealers were applied to horizontal laboratory specimens (slabs), vertical laboratory specimens (wall sections), and bridges (high-volume and moderate-volume). Control sections were also included in all specimen types. The laboratory specimens were exposed to a 3% NaCl solution for 30 1-week cycles, each cycle being three days of exposure and four days of air drying. Background chlorides and the chloride ion profiles were determined after 10, 20 and 30 cycles of saltwater exposure. The surface absorption test was conducted at various intervals throughout the cycles. The surface absorption test was also used to attempt to measure the traffic wear effect on the field specimens. The results indicate that the two epoxies exhibited very little effectiveness in preventing chlorides from entering the concrete. The silane and siloxane sealers performed much better in the laboratory settings, retaining over 90% reduction of chlorides throughout the test period. A service life model which includes laboratory performance and considers application exposure conditions is suggested. It has been discovered that, at present, surface absorption testing may be used on a limited basis to obtain results which indicate sealer effectiveness, but only if the testing occurs under extremely limited or controlled environments.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Civil Engineering
Department dc:contributor.department
Civil Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1992

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Drumm, Rick O.
Chairs dc:contributor.committeechair
  • Weyers, Richard E.
  • Al-Qadi, Imadeddin L.
Committee member dc:contributor.committeemember
  • Murray, Thomas M.

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-10102009-020244
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/45130

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Drumm, Rick O.. Determination of the service life of concrete sealers on horizontal and vertical bridge members. masters thesis, Virginia Tech, 1992. http://hdl.handle.net/10919/45130